The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

21701–21725 of 40339

  • HighFDA (Devices)·Z-0522-2019·2018-12-05

    GE Healthcare Recalls Solar 8000i Patient Monitoring Systems

    GE Healthcare is recalling approximately 73,673 Solar 8000i and 8000M patient monitoring systems because they may simultaneously restart during prolonged network overloads.

    Product
    Solar 8000i Patient Monitoring System is used to monitor physiologic parameter data on adult, pediatric and neonatal patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0518-2019·2018-12-05

    Fresenius Granuflo Dry Acid Concentrate Recalled for Foreign Substance

    Fresenius Medical Care is recalling Granuflo Dry Acid Concentrate for hemodialysis due to confirmed foreign substance contamination.

    Product
    Fresenius Granuflo Dry Acid Concentrate- 3K 2.5 Ca 1 Mg 16.5 GAL Catalog Number: OFD3251-3B for hemodialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0501-2019·2018-12-05

    NxStage PureFlow B Solution Recalled Due to Bag Burst Risk

    NxStage Medical is recalling PureFlow B Solution because the smaller chamber of the two-chamber bag can burst, releasing electrolyte fluid that may injure eyes or skin.

    Product
    NxStage PureFlow B Solution-RFP-401, Premixed Dialysate for Hemodialysis NxStage PureFlow B Solution is indicated for use with renal replacement therapy systems that utilize sterile premixed dialysate during hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0515-2019·2018-12-05

    Eurotrol HemoTrol Level 3 Recalled Due to Microbial Contamination

    Eurotrol Inc. is recalling HemoTrol Level 3 hematology quality control mixtures because microbial contamination causes incorrect, lower-than-assigned measurement results.

    Product
    HemoTrol Level 3- In Vitro Diagnostic Hematology quality control mixture. Catalogue number: 171.003.002 Eurotrol HemoLin is an assayed hemoglobin control intended for professional use in the verification of the linearity of the HemoCue¿ Hb 201 systems.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0520-2019·2018-12-05

    GE Healthcare Recalls Dash 4000 Patient Monitoring Systems

    GE Healthcare is recalling Dash 4000 Patient Monitoring Systems because they may simultaneously restart if connected to the same network during a prolonged network overload.

    Product
    Dash 4000 Patient Monitoring System is used to monitor physiologic parameter data on adult, pediatric and neonatal patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0504-2019·2018-12-05

    NxStage PureFlow B Solution Recalled for Potential Bag Burst Injury Risk

    NxStage Medical is recalling PureFlow B Solution because the smaller chamber of the two-chamber bag can burst, releasing electrolyte fluid that may cause injury if it contacts eyes or skin.

    Product
    NxStage PureFlow B Solution-RFP-404, Premixed Dialysate for Hemodialysis NxStage PureFlow B Solution is indicated for use with renal replacement therapy systems that utilize sterile premixed dialysate during hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0500-2019·2018-12-05

    NxStage PureFlow B Solution Recalled for Potential Bag Bursting

    NxStage Medical is recalling 59,100 units of PureFlow B Solution because the smaller chamber may burst, releasing electrolyte fluid that can injure eyes or skin.

    Product
    NxStage PureFlow B Solution-RFP-400, Premixed Dialysate for Hemodialysis. NxStage PureFlow B Solution is indicated for use with renal replacement therapy systems that utilize sterile premixed dialysate during hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0503-2019·2018-12-05

    NxStage PureFlow B Solution Recalled Due to Bag Burst Risk

    NxStage Medical is recalling 2,189 units of PureFlow B Solution because the bag's smaller chamber can burst, releasing electrolyte fluid that may injure eyes or skin.

    Product
    NxStage PureFlow B Solution-RFP-403, Premixed Dialysate for Hemodialysis NxStage PureFlow B Solution is indicated for use with renal replacement therapy systems that utilize sterile premixed dialysate during hemodialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0512-2019·2018-12-05

    Smiths Medical Recalls Medex High Pressure Stopcocks Due to Leak Risk

    Smiths Medical ASD Inc. is recalling specific lots of Medex High Pressure Stopcocks because an inner body defect may cause the device to leak.

    Product
    Medex High Pressure Stopcock used to control the direction of IV fluid flow. This device is intended for single use only and is provided sterile and fluid path non-pyrogenic unless package is damaged or opened.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0510-2019·2018-12-05

    Numed Multi-Track Angiographic Catheter Recall for Missing Instructions

    Numed Inc is recalling 100 units of Multi-Track Angiographic Catheters because the Instructions for Use booklets were not included on the outer pouch.

    Product
    Multi-Track Angiographic Catheter (MMTA) Product Code: MMTA05100 Product Usage: Recommended for use in catheterization for angiography of cardiovascular vessels and I or chambers. It can be used for injection of contrast medium and pressure measurement in any chamber or…
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0517-2019·2018-12-05

    Fresenius Granuflo Dry Acid Concentrate Recalled for Foreign Substance

    Fresenius Medical Care is recalling specific lots of Granuflo Dry Acid Concentrate for hemodialysis due to the presence of a foreign substance.

    Product
    Fresenius Granuflo Dry Acid Concentrate- 2K 2.5 Ca 1 Mg 16.5 GAL Catalog Number: OFD2251-3B for hemodialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0519-2019·2018-12-05

    GE Healthcare Recalls Dash 3000 Patient Monitoring Systems

    GE Healthcare is recalling Dash 3000 patient monitors because they may restart simultaneously during prolonged network overloads.

    Product
    Dash 3000 Patient Monitoring System is used to monitor physiologic parameter data on adult, pediatric and neonatal patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0498-2019·2018-12-05

    Stryker Recalls Reprocessed Xcel Bladeless Trocars Due to Distribution Error

    Stryker Sustainability Solutions is recalling 4,848 reprocessed Xcel Bladeless Trocars (H12LP) because they were distributed to facilities after a previous recall was executed.

    Product
    Reprocessed Xcel Bladeless Trocar (H12LP) Model # H12LP Reprocessed Endoscopic Trocars12x100mm - Product Usage: Physical Product Description: The Reprocessed Blunt Tip Trocar consists of a radiolucent cannula and obturator sized 12mm in diameter (refer to Figure 1). The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0513-2019·2018-12-05

    PerkinElmer QSight 210 MD Mass Spectrometer Software Data Overwrite Recall

    PerkinElmer is recalling 18 QSight 210 MD mass spectrometers because a software defect may overwrite original data from the last acquired sample when automatic flush is enabled.

    Product
    PerkinElmer QSight 210 MD Mass Spectrometer Simplicity 3Q MD v1.0 with Hot Fix 2 Software intended to identify compounds in human samples by ionizing the compound and separating the resulting ions. Part Number: BC004872
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-0509-2019·2018-12-05

    Tosoh AIA-900 Analyzer Recalled for Potential Drive Motor Failure

    Tosoh Bioscience is recalling 247 AIA-900 Automated Immunoassay Analyzers due to a potential drive motor defect that may cause the device to stop functioning and delay patient test results.

    Product
    AIA-900 Automated Immunoassay Analyzer, product code 022930 /022930R Product Usage: The AIA-900 is capable of performing three methods of immunoassay: an immunoenzymetric (IEMA) or sandwich immunoassay, a competitive binding (EIA) immunoassay, and a two-step immunoenzymetric…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0499-2019·2018-12-05

    Siemens Dimension Vista Lactate Dehydrogenase Reagent Cartridge Recall

    Siemens is recalling Dimension Vista Lactate Dehydrogenase reagent cartridges because they may produce falsely elevated results if used after Lactic Acid assays.

    Product
    Dimension Vista Lactate Dehydrogenase (LDI) Flex reagent cartridge, an in vitro diagnostic test for the quantitative measurement of lactate dehydrogenase in human serum and plasma on the Dimension Vista¿ System.Cat. No. K2054, Mat. No. 10464323
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0516-2019·2018-12-05

    Fresenius Granuflo Dry Acid Concentrate Recalled for Foreign Substance

    Fresenius Medical Care is recalling Granuflo Dry Acid Concentrate for hemodialysis due to confirmed foreign substance contamination.

    Product
    Fresenius Granuflo Dry Acid Concentrate- 2K 2.0 Ca 1 Mg 16.5 GAL Catalog Number: OFD2201-3B for hemodialysis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0511-2019·2018-12-05

    Numed Multi-Track Angiographic Catheter Recall for Missing Instructions

    Numed Inc is recalling 100 units of Multi-Track Angiographic Catheters because Instructions for Use booklets were not included on the outer pouch.

    Product
    Multi-Track Angiographic Catheter (MMTA) Product Code: MMTA06100 Product Usage: Recommended for use in catheterization for angiography of cardiovascular vessels and I or chambers. It can be used for injection of contrast medium and pressure measurement in any chamber or…
    Category
    Medical Device
    Distribution
    1 state
  • LowFDA (Devices)·Z-0508-2019·2018-12-05

    WOM World of Medicine Recalls PNEUMOCLEAR Heated High-Flow Tube Sets

    WOM World of Medicine AG is recalling PNEUMOCLEAR Heated High-Flow Tube Sets because packaging may be damaged by the tube set prongs.

    Product
    PNEUMOCLEAR Heated High-Flow Tube Set Product Usage: The Heated High-Flow Tube Set is a single use sterile tube set used in combination with the PNEUMOCLEAR C02 insufflator as a separate accessory. The device PNEUMOCLEAR is a C02 insufflator intended for use during…
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0471-2019·2018-11-28

    Beckman Coulter Flow Cytometers Recalled for Amplifier Board Defect

    Beckman Coulter is recalling Cytomics FC 500 and EPICS XL flow cytometers due to a manufacturing defect on the amplifier board that may cause signal loss or drifting.

    Product
    1) Cytomics FC 500 With CXP Software BECKMAN COULTER 2) Cytomics FC 500 MPL With MXP Software BECKMAN COULTER flow cytometer for in vitro diagnostics
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0472-2019·2018-11-28

    Beckman Coulter Flow Cytometers Recalled for Signal Loss Defect

    Beckman Coulter is recalling 2,549 flow cytometers worldwide due to a manufacturing defect that may cause signal loss or drifting, potentially affecting patient results.

    Product
    COULTER EPICS XL Flow Cytometer COULTER EPICS XL-MCL Flow Cytometer SYSTEM II Software
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0488-2019·2018-11-28

    Sedecal NOVA FA DR System Recalled for Potential Cable Failure

    Sedecal S.A. is recalling 145 NOVA FA DR diagnostic radiography systems because installation or maintenance issues could cause support cables to break, leading to equipment falling.

    Product
    Sedecal NOVA FA DR System. for diagnostic radiography.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0478-2019·2018-11-28

    Voluntis Recalls Insulia Diabetes Management Companion Due to Calculator Bug

    Voluntis is recalling the Insulia Diabetes Management Companion because a bug in the Android basal calculator could cause hypoglycemia. An update is available to resolve the issue.

    Product
    Insulia Diabetes Management Companion
    Category
    Medical Device
    Distribution
    5 states
  • SevereFDA (Devices)·Z-0474-2019·2018-11-28

    Boston Scientific Recalls SQ-RX Pulse Generators for Battery Malfunctions

    Boston Scientific is recalling 12,900 SQ-RX Pulse Generators used in S-ICD systems due to latent internal battery malfunctions that cause accelerated depletion.

    Product
    The SQ-RX Pulse Generator a component of the Subcutaneous Implantable Cardioverter Defibrillator (S-ICD) System The S-ICD System is intended to provide defibrillation therapy for the treatment of life-threatening ventricular tachyarrhythmias in patients who do not have…
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.