The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

20476–20500 of 40287

  • SevereFDA (Devices)·Z-1573-2019·2019-06-05

    Maquet Getinge Adult ECC Pack Recall Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling Adult ECC Packs because a design feature may prevent sterilization gas from reaching all fluid paths, potentially compromising sterility.

    Product
    Maquet Getinge-BO-TOP 36504 ADULT ECC PACK Material: 701065765
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1519-2019·2019-06-05

    Maquet Custom Tubing Sets Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design feature may prevent sterilization gas from reaching all fluid paths.

    Product
    Maquet Getinge-BEQ-TOP 27901 SMALL PATIENT CI Material:701052287
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1526-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design flaw may prevent proper sterilization of the stopcock ports.

    Product
    Maquet Getinge-BO-TOP 20705 SMALL PATIENT 1/4 Material: 701053486
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1537-2019·2019-06-05

    Maquet Getinge ECC Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific ECC tubing sets because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-T 8025 1/4" ECC Pack with RF32 Material:701055142
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1547-2019·2019-06-05

    Maquet Getinge ECC Tubing Sets Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific batches of Getinge-BEQ-TOP 38900 ECC Packs because a design flaw may prevent proper sterilization of the stopcock ports.

    Product
    Maquet Getinge-BEQ-TOP 38900 ECC PACK Material: 701056368
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1511-2019·2019-06-05

    Maquet Getinge-BEQ-TOP Circulatory Circuits Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific batches of Maquet Getinge-BEQ-TOP 15704 Circulatory Circuits because a design feature may prevent proper sterilization of the stopcock ports.

    Product
    Maquet Getinge-BEQ-TOP 15704 Circulatory Circuit 3/8" Material: 701050859
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1376-2019·2019-06-05

    Terumo Portico Solo Re-Collapsible Access System Recalled for Tip Dislodgement

    Terumo Medical Corporation is recalling Portico Solo Re-Collapsible Access Systems because the tip may dislodge from the sheath, potentially causing injury.

    Product
    Portico Solo Re-Collapsible Access System , Model Numbers PRTSOLO-19, PRTSOLO-20
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1375-2019·2019-06-05

    Terumo SOLOPATH Re-Collapsible Access System Recalled for Tip Dislodgement Risk

    Terumo Medical Corporation is recalling 1,431 SOLOPATH Re-Collapsible Access Systems because the tip may dislodge from the sheath, potentially compromising the device's smooth transition.

    Product
    SOLOPATH Re-Collapsible Access System, Model Numbers SR-1925, SR-1935, SR-2025, SR-2035, SR-2225, SR-2235, SR-2425, SR-2435
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1670-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization gas flow, compromising sterility.

    Product
    Maquet Getinge BEQ-T 3501 LVAD 3/8" Material: 701068008R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1638-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent sterilization gas from reaching all parts of the device.

    Product
    Maquet Getinge-BO-TOP 15200 OR PACK HMO & RF Material:701050647R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1637-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge- BEQ-TOP 5900 TCH 3/8 Quadrox-iD Pack Material:701050228R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1575-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-T 46500 PRIME PACK Material:701065823
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1515-2019·2019-06-05

    Maquet Getinge ECC Tubing Sets Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific Custom Tubing Sets for Extracorporeal Circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 22702 ECC W/HMOD 30000 Material: 701051179
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1687-2019·2019-06-05

    Abbott MitraClip XTR Clip Delivery System Recalled for Malfunction

    Abbott Vascular is recalling the MitraClip XTR Clip Delivery System because clips may open or become nonfunctional during implantation, requiring additional surgery.

    Product
    Abbott MitraClip XTR Clip Delivery System, UDI: 08717648226366, Part: CDS0601-XTR, Sterile EO, Rx Only
    Category
    Medical Device
    Distribution
    49 states
  • SevereFDA (Devices)·Z-1374-2019·2019-06-05

    Terumo Recalls SoloPath Balloon Expandable TransFemoral Systems Due to Tip Dislodgement Risk

    Terumo Medical Corporation is recalling 2,228 SoloPath Balloon Expandable TransFemoral Systems because the device tip may dislodge from the sheath, potentially causing vessel trauma.

    Product
    SOLOPATH Balloon Expandable TransFemoral System, Model Numbers STFI-1425, STFI-1435, STFI-1625, STFI-1635, STFI-1825, STFI-1835, STFI-1925, STFI-1935, STFI-2125, STFI-2135 Product Usage: The SoloPath Balloon Expandable TransFemoral Introducer System (STFI)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1544-2019·2019-06-05

    Maquet Getinge-T 8028 Pressure Pigtail Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific Pressure Pigtail devices because a design feature may prevent sterilization gas from reaching all fluid paths, potentially compromising sterility.

    Product
    Maquet Getinge-T 8028 PRESSURE PIGTAIL 4" Material: 701055993
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1633-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design flaw may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 22600 ECC QUADROX iD 3/8 Material:701049440R02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1666-2019·2019-06-05

    Maquet Getinge NICU ECC Pack Recall Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling NICU ECC Packs because a design feature may prevent sterilization gas from reaching all fluid paths, compromising sterility.

    Product
    Maquet Getinge- BEQ-TOP 39202 NICU ECC PACK Material: 701067313R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1669-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design flaw may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge- (1) Material :701067370R01 BO-TOP 38803 OPEN HEART PACK W (2) Material: 701067370R02 BO-TOP 38803 OPEN HEART PACK W (3) Material: 701067370R03 BO-TOP 38803 OPEN HEART PACK W
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1507-2019·2019-06-05

    Maquet Getinge-BEQ-TOP 5900 Custom Tubing Sets Recalled for Sterility Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design flaw may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 5900 3/8 Quadrox iD Pack w/BB Material: 701050228
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1521-2019·2019-06-05

    Maquet Getinge-BEQ-TOP 25500 ECC Tubing Sets Recalled for Sterility Assurance Issues

    Maquet Cardiovascular is recalling specific Custom Tubing Sets for Extracorporeal Circulation because the design may prevent proper sterilization gas flow, compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 25500 ECC 3/8 w/QiD Material: 701052461
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1574-2019·2019-06-05

    Maquet Getinge ECC Pump Packs Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific ECC Pump Packs because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 30907 ECC PUMP PACK Material: 701065770
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1660-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge- BEQ-T 5211 ECC Large Children's Hospital Material: 701064560R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1615-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent sterilization gas from reaching all parts of the device.

    Product
    Maquet Getinge-BEQ-T 36507 Accessory Pk Mercy Material: 709000390
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.