The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

1626–1650 of 40489

  • ModerateFDA (Devices)·Z-1963-2026·2026-05-06

    Philips Ingenia Elition X MRI Scanner Recall for Image Reconstruction Error

    Philips is recalling Ingenia Elition X MRI scanners with MR Elastography due to potential errors in stiffness value measurements when specific image reconstruction parameters are used, which may cause incorrect voxel size display in the default scan protocol.

    Product
    Philips Ingenia Elition X with MR Elastography (MRE). 1. Model Number (REF): 781358. 2. Model Number (REF): 782107. 3. Model Number (REF): 782136. 510(k) Numbers: K213516, K223458, K230972, K232030, K251397, K251808
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1961-2026·2026-05-06

    Philips Ingenia Ambition X MRI Systems Stiffness Value Error Recall

    Philips Ingenia Ambition X MRI systems with MR Elastography may produce incorrect stiffness values due to image reconstruction parameter errors, affecting diagnostic accuracy.

    Product
    Philips Ingenia Ambition X with MR Elastography (MRE). 1. Model Number (REF): 781356. 2. Model Number (REF): 782109. 3. Model Number (REF): 782138. 4. Model Number (REF): 782160.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1988-2026·2026-05-06

    DePuy Synthes ATTUNE Revision Hinge Femoral Component Sterility Recall

    DePuy Synthes is recalling 3 units of ATTUNE REVISION HINGE FEMORAL LT SZ 8 CEM due to external sterile packaging adhered to internal packaging, potentially compromising sterility.

    Product
    Depuy Synthes, ATTUNE REVISION HINGE FEMORAL LT SZ 8 CEM. Part Number: 150450108.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1967-2026·2026-05-06

    Philips SmartPath to dStream MR Elastography Software Parameter Error

    Philips is recalling specific units of SmartPath to dStream for XR and 3.0T with MR Elastography due to potential stiffness value errors when certain image reconstruction parameters are used with Resoundant's algorithm, which may cause voxel size settings in the default MRE scan protocol to display incorrectly.

    Product
    Philips SmartPath to dStream for XR and 3.0T with MR Elastography (MRE). 1. Model Number (REF): 781270. 2. Model Number (REF): 782113.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1968-2026·2026-05-06

    Philips SmartPath to Ingenia Elition X MR Elastography Stiffness Value Errors

    Philips is recalling three models of SmartPath to Ingenia Elition X with MR Elastography devices due to potential stiffness value errors when specific image reconstruction parameters are combined with Resoundant's algorithm.

    Product
    Philips SmartPath to Ingenia Elition X with MR Elastography (MRE). 1. Model Number (REF): 782118. 2. Model Number (REF): 782144. 3. Model Number (REF): 782163.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1964-2026·2026-05-06

    Philips MR 7700 MR Elastography device stiffness value error recall

    Philips is recalling certain MR 7700 devices with MR Elastography due to potential stiffness value errors when specific image reconstruction parameters are used, which may cause voxel size settings to display incorrectly.

    Product
    Philips MR 7700 with MR Elastography (MRE). 1. Model Number (REF): 782120. 2. Model Number (REF): 782153.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1952-2026·2026-05-06

    Philips Achieva 1.5T MRI System MRE Protocol Parameter Error Recall

    Philips Achieva 1.5T MRI systems with MR Elastography may display incorrect stiffness values and voxel size settings when certain image reconstruction parameters are used together, potentially affecting diagnostic accuracy.

    Product
    Philips Achieva 1.5T Initial system with MR Elastography (MRE). 1. Model Number (REF): 781178.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2008-2026·2026-05-06

    Medline Neuro Sponges recalled for out-of-specification endotoxin levels

    Medline Industries is recalling Medline Neuro Sponges in multiple sizes worldwide after internal review found higher-than-expected endotoxin levels in representative product samples.

    Product
    Medline Neuro Sponges, various dimensions, labeled as: 1. Neuro Sponges, Eponges neuro, Neuroesponjas, size 0.25" X 0.25", XR, 10/PK, Medline SKU NEUROSPNG02; 2. Neuro Sponges, Eponges neuro, Neuroesponjas, size 0.5" X 0.5", XR, 10/PK, Medline SKU NEUROSPNG05; 3.…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1949-2026·2026-05-06

    Genius Review Station Display Modified Outside Validated Configuration

    Hologic is correcting Genius Review Station displays (model CMP-01669) that were modified by users outside the FDA-cleared configuration. The devices need restoration to validated settings per the manufacturer's Operator's Manual.

    Product
    Brand Name: Genius" Review Station Product Name: Genius" Review Station Display (Barco Monitor) Model/Catalog Number: CMP-01669 Software Version: N/A - not software version specific Component: Yes, the Genius" Review Station is a component of the Genius" Digital Diagnostics…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1946-2026·2026-05-06

    Disposable Mixing Bowls with Spatula recalled for compromised sterile barrier

    Zimmer, Inc. is recalling Disposable Mixing Bowls with Spatula (Model 00-5049-011-00) due to package seal defects that may compromise the sterile barrier. Ten complaints have been received identifying incomplete seals, wrinkles, or peeling seals.

    Product
    Brand Name: Disposable Mixing Bowls with Spatula Product Name: Mixing Bowl and Spatula Model/Catalog Number: 00-5049-011-00 Software Version: N/A Product Description: Mixing Bowl and Spatula Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1983-2026·2026-05-06

    BD GasPak EZ Campy Pouch System Recall for Below-Specification Gas Production

    Becton Dickinson & Co. is recalling certain lots of BD GasPak EZ Campy Gas Generating Pouch Systems because gas generating sachets may produce carbon dioxide levels below specification, potentially affecting microbiologic laboratory testing.

    Product
    BD GasPak EZ Campy Pouch System. Catalog Number: 260685. for microbiologic use
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1993-2026·2026-05-06

    DePuy Synthes ATTUNE Revision Hinge Femoral implant sterility concern

    DePuy Synthes is recalling 3 units of ATTUNE Revision Hinge Femoral RT SZ 8 CEM implants due to external sterile packaging adhered to internal sterile packaging, potentially compromising sterility.

    Product
    Depuy Synthes, ATTUNE REVISION HINGE FEMORAL RT SZ 8 CEM. Part Number: 150450208.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1945-2026·2026-05-06

    Kiwi Omni Vacuum Delivery System devices recalled for traction force gauge breakage

    Clinical Innovations is recalling the Kiwi Omni Vacuum Delivery System (Model VAC-6000MT) due to complaints of device breakage at the traction force gauge to handle joint. The recall affects 49,175 devices distributed nationwide and internationally.

    Product
    Brand Name: Kiwi Omni Vacuum Delivery System Product Name: Kiwi Omni Vacuum Delivery System Model/Catalog Number: VAC-6000MT Product Description: The Clinical Innovations Kiwi is a disposable vacuum assisted fetal delivery system. It is a sterile, single-patient-use device…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1950-2026·2026-05-06

    HiResolution Bionic Ear Battery Pak Fails Safety Door Compliance

    Advanced Bionics is recalling HiResolution Bionic Ear System M Zn-Air Battery Paks because the non-tamperproof battery door does not require a tool to open, violating safety standards. The issue affects 45,173 units distributed worldwide.

    Product
    Brand Name: HiResolution" Bionic Ear System Product Name: M Zn-Air Battery Pak Model/Catalog Number: CI-5501-110; CI-5501-120; CI-5501-130; CI-5501-140; CI-5501-150; CI-5501-190; CI-5501-240; CI-5501-250; CI-5501-260; CI-5501-270; CI-5501-280 Software Version: Not Applicable…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1944-2026·2026-05-06

    Vacuum Bag SU Large non-sterile specimen container recall

    Milestone S.R.L. is recalling Vacuum Bag SU Large non-sterile specimen containers (Model 68409SS) due to the possibility of reagent leakage from the container. The recall affects approximately 61,600 units distributed worldwide.

    Product
    VACUUM BAG SU LARGE, Non-sterile specimen container, Model/Catalog Number: 68409SS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1959-2026·2026-05-06

    Philips Ingenia 3.0T CX MRI System MR Elastography Software Issue

    Philips is recalling Ingenia 3.0T CX MRI systems with MR Elastography due to potential stiffness value errors caused by specific image reconstruction parameters and Resoundant algorithm settings, resulting in incorrect voxel size displays in the default MRE scan protocol.

    Product
    Philips Ingenia 3.0T CX with MR Elastography (MRE). 1. Model Number (REF): 781271. 2. Model Number (REF): 782105. 510(k) Numbers: K173079, K183063, K193215, K213583, K223458, K251397, K251808.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1958-2026·2026-05-06

    Philips Ingenia 3.0T MRI System with Elastography Software Recall

    Philips Ingenia 3.0T MRI systems with MR Elastography software may display incorrect stiffness values and voxel size settings when specific image reconstruction parameters are used, potentially affecting diagnostic accuracy.

    Product
    Philips Ingenia 3.0T with MR Elastography (MRE). 1. Model Number (REF): 781342. 2. Model Number (REF): 781377. 3. Model Number (REF): 782103. 510(k) Numbers: K163116, K173079, K183063, K193215, K213516, K213583, K223458, K251397, K251808
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1956-2026·2026-05-06

    Philips Ingenia 1.5T MRI System Stiffness Value Calculation Error Recall

    Philips Ingenia 1.5T MRI systems with MR Elastography may display incorrect stiffness values and voxel size settings due to image reconstruction parameter combinations. The error affects 54 units distributed worldwide.

    Product
    Philips Ingenia 1.5T with MR Elastography (MRE). 1. Model Number (REF): 781315. 2. Model Number (REF): 781341. 3. Model Number (REF): 781396. 4. Model Number (REF): 782115. 510(k) Numbers: K163116, K173079, K183063, K193215, K213583, K223458, K251397, K251808
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1966-2026·2026-05-06

    Philips SmartPath dStream 3.0T MRI Scanner Software Parameter Error Recall

    Philips is recalling one unit of the SmartPath to dStream 3.0T MRI scanner with MR Elastography due to potential stiffness value calculation errors when specific image reconstruction parameters are used.

    Product
    Philips SmartPath to dStream for 3.0T with MR Elastography (MRE). 1. Model Number (REF): 782145.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1955-2026·2026-05-06

    Philips Evolution 3.0T MR Elastography upgrade stiffness calculation error

    Philips Evolution upgrade 3.0T with MR Elastography systems may produce incorrect stiffness values when specific image reconstruction parameters are used, causing voxel size settings to display smaller than intended.

    Product
    Philips Evolution upgrade 3.0T with MR Elastography (MRE). 1. Model Number (REF): 782143. 2. Model Number (REF): 782162.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1957-2026·2026-05-06

    Philips Ingenia 1.5T CX MRI Machine MRE Stiffness Measurement Error

    Philips is recalling the Ingenia 1.5T CX MRI machine with MR Elastography because certain image reconstruction parameters may cause stiffness value measurement errors in the default scan protocol.

    Product
    Philips Ingenia 1.5T CX with MR Elastography (MRE). 1. Model Number (REF): 781262.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2002-2026·2026-05-06

    Philips Bridge Prep Kit catheter may experience resistance during advancement

    Merit Medical Systems is recalling the Philips Bridge Prep Kit (Lot K12-09098B) because the catheter may experience resistance when being advanced over the guidewire.

    Product
    Philips Bridge Prep Kit REF: K12-09098B Sterile EO, Rx ONLY
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2037-2026·2026-05-06

    Medline medical procedure kits recalled for endotoxin contamination

    Medline is recalling medical procedure kits containing Neuro Sponges due to higher-than-expected endotoxin levels. The affected in-market product may be out-of-specification for endotoxin.

    Product
    Medline medical procedure kits, containing Medline Neuro Sponges, labeled as follows: 1. CATARACT PACK, Medline Kit Number/SKU DYNJ48725A; 2. OCULAR PACK, Medline Kit Number/SKU DYNJ64138B; 3. OCULOPLASTY PACK, Medline Kit Number/SKU DYNJ64572A; 4. OCULOPLASTY PACK…
    Category
    Medical Device
    Distribution
    0 states
  • LowFDA (Devices)·Z-1998-2026·2026-05-06

    Heraeus PALAMIX duo dental mixing system batches worldwide recall

    Heraeus Medical is recalling PALAMIX duo dental mixing units (Material Number 66057897) because the mixing rod may come loose from its lock during use in units older than 1.5 years. The shelf life is being reduced from 3 years to 1.5 years.

    Product
    Heraeus, PALAMIX duo. Material Number: 66057897.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1997-2026·2026-05-06

    Heraeus PALAMIX uno Dental Material Mixing Rod Loose Risk Recall

    Heraeus Medical is recalling PALAMIX uno dental material because the mixing rod may come loose during mixing in units older than 1.5 years. The shelf life has been reduced from 3 years to 1.5 years.

    Product
    Heraeus, PALAMIX uno. Material Number: 66057893.
    Category
    Medical Device
    Distribution
    Distributed nationwide