The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

876–900 of 40489

  • SevereFDA (Devices)·Z-2704-2026·2026-07-22

    Transvenous Pacing Electrode Tray with Bipolar Balloon Pacing Electrode Recalled

    Argon Medical Devices is recalling Transvenous Pacing Electrode Trays with Bipolar Balloon Pacing Electrode 5F because kits containing Lidocaine HCL Injection USP did not meet sterility release criteria.

    Product
    Transvenous Pacing Electrode Tray w/ Bipolar Balloon Pacing Electrode 5F, REF: 008416A, 008566A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2720-2026·2026-07-22

    Olympus Ellik Evacuator Recalled for Inadequate Sterilization Risk

    Olympus Corporation of the Americas is recalling the Olympus Ellik Evacuator (Model 194) worldwide because certain sterilization parameters in the instructions may not render the device adequately sterile.

    Product
    Olympus Ellik Evacuator Includes Glass Body, Male Connecting Tubing & Latex Bulb. Model Number: 194.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2724-2026·2026-07-22

    ICU Medical Plum Solo Precision IV Pump May Deliver Excess Medication

    ICU Medical is recalling the Plum Solo Precision IV Pump (v1.0.3) because in specific scenarios, the pump may fail to decrease the displayed volume and could deliver up to twice the programmed medication amount.

    Product
    ICU Medical Plum Solo Precision IV Pump, v1.0.3, Item Number 400010401; infusion pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2685-2026·2026-07-22

    Abiomed Impella CP Introducer Kit heart pump accessory recall

    Abiomed is recalling Impella CP Introducer Kits worldwide due to potential leakage from the introducer sheath that cannot be visually detected by users. The manufacturing defect affects 1,540 units across multiple countries.

    Product
    ABIOMED Impella CP Introducer Kit 14 Fr, 13 cm, Pump Set Code 0052-0038, containing Kit, 14Fr Introducer, 13cm, Long Taper, Introducer Product Code 0052-3052. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2687-2026·2026-07-22

    ABIOMED Impella 5.5 Heart Pump Introducer Sheath Leakage Risk Recall

    Abiomed is recalling the Impella 5.5 Smart Assist Set heart pump due to potential leakage from introducer sheaths. The defect is not visually detectable and affects all affected pump sets worldwide.

    Product
    ABIOMED Impella 5.5 Smart Assist Set, JP, Pump Set Codes 1000211, 1000212; containing Introducer Product Code 0052-3006-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2705-2026·2026-07-22

    One-Piece Introducer Tray kits recalled for sterility failure

    Argon Medical Devices is recalling One-Piece Introducer Tray kits containing Lidocaine HCL Injection because they do not meet sterility release criteria. The kits were distributed nationwide and internationally.

    Product
    One-Piece Introducer Tray, REF: 497455, 497434 cardiovascular
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2723-2026·2026-07-22

    ICU Medical Plum Duo Infusion Pump Software Defect Affecting Drug Delivery

    ICU Medical is recalling Plum Duo Infusion Pump v1.2.3 units due to a software defect that may cause the pump to deliver up to twice the programmed volume without decrementing the display, risking patient overdose.

    Product
    ICU Medical Plum Duo Infusion Pump, v1.2.3: 1) Item Number 400020401 and 2) Item Number 400020403; infusion pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2692-2026·2026-07-22

    ABIOMED Insertion Kit heart pump accessories introducer sheath leakage

    Abiomed is recalling ABIOMED Insertion Kits due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines. The manufacturing defect is not visually detectable by users.

    Product
    ABIOMED Insertion Kit, Pkgd, JP, Pump Set Code 0052-0011-JP; containing Introducer Product Code 0052-3006-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2681-2026·2026-07-22

    ABIOMED Impella RP Flex heart pump introducer sheath leakage risk

    Abiomed is recalling the Impella RP Flex heart pump due to potential introducer sheath leakage from the sheath cap and hub score lines. The manufacturing defect is not visually detectable.

    Product
    ABIOMED Impella RP Flex with SmartAssist Set, Pump Set Code 1000323, containing Kit, 23Fr Introducer, 11cm, Sterile, 23 Fr, 11 cm, Product Code 2000342. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2739-2026·2026-07-22

    Medtronic Bio-Medicus Adult Cannula Kit Recalled for Foreign Material

    Medtronic is recalling its Bio-Medicus Adult Cannula Kit (Product Number 96530-115) used in cardiopulmonary bypass procedures due to the discovery of loose foreign material containing trace levels of blood in two units.

    Product
    Medtronic Bio-Medicus Adult Cannula Kit, Product Number/CFN 96530-115; Cardiopulmonary bypass vascular cannula
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2688-2026·2026-07-22

    Abiomed Impella 5.5 SmartAssist S2 heart pump introducer sheath leakage risk

    Abiomed is recalling Impella 5.5 SmartAssist S2 heart pump sets worldwide due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines that may not be visible to users.

    Product
    ABIOMED Impella 5.5 SmartAssist S2 Set, JP, Pump Set Codes 1000459, 1000460; containing Introducer Product Code 0052-3006-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2709-2026·2026-07-22

    Bone Marrow Tray kits recalled due to sterility failure

    Argon Medical Devices is recalling Bone Marrow Tray kits containing Lidocaine HCL Injection because they do not meet sterility release criteria.

    Product
    Bone Marrow Tray, REF: CB0033TL; CB0355TLA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2719-2026·2026-07-22

    Olympus Toomey Evacuator 50cc with Adaptor sterilization recall

    Olympus is recalling the Toomey Evacuator 50cc with Adaptor (Model 188A) because some sterilization parameters in the instructions may not reliably render the devices sterile.

    Product
    Olympus Toomey Evacuator 50cc with Adaptor. Model Number: 188A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2721-2026·2026-07-22

    Olympus Glass Body for 194 Ellik Evacuator Model 190A Sterilization Recall

    Olympus Corporation is recalling the Glass Body for 194 Ellik Evacuator (Model 190A) because certain sterilization parameters in the instructions may not consistently render the devices adequately sterile.

    Product
    Olympus Glass Body for 194 Ellik Evacuator. Model Number: 190A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2727-2026·2026-07-22

    GE Optima XR200/220/240amx Radiographic System Column Safety Mechanism

    GE Medical Systems is recalling certain Optima XR200/220/240amx mobile radiographic systems after column replacements because functional testing of the safety pawl may not have been performed, which could allow the X-ray arm to drop and injure patients.

    Product
    Optima XR220amx, Mobile Digital-Ready Radiographic System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2718-2026·2026-07-22

    Olympus Toomey Evacuator 30cc medical device sterilization parameters recalled

    Olympus Corporation recalled the Toomey Evacuator 30cc with Adaptor (Model 188) because certain sterilization parameters in the instructions may not consistently render the devices adequately sterile.

    Product
    Olympus Toomey Evacuator 30cc with Adaptor. Model Number: 188.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2741-2026·2026-07-22

    Vasoview Hemopro 2 Endoscopic Vessel Harvesting System Recall

    Maquet Cardiovascular is recalling Vasoview Hemopro 2 devices from Lot 3000547797 due to exposure to out-of-specification sterilization during gamma sterilization. The affected devices may not be properly sterilized.

    Product
    The Vasoview Hemopro 2 Endoscopic Vessel Harvesting System (Model VH-4000; UDI 00607567700406) is a sterile, single-use Class II device that was cleared for marketing by FDA under 510(k) number K101274.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2738-2026·2026-07-22

    Medtronic DLP One-Piece Pediatric Arterial Cannula Recalled for Foreign Material

    Medtronic is recalling certain DLP One-Piece Pediatric Arterial Cannulas (Product Number 77010) due to complaints of loose foreign material containing trace levels of blood found in the devices.

    Product
    Medtronic DLP One-Piece Pediatric Arterial Cannula, Product Number/CFN 77010; Cardiopulmonary bypass vascular cannula
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2730-2026·2026-07-22

    Orthofix MINIRAIL external fixation devices recalled for incorrect labeling

    Orthofix U.S. LLC is recalling 19 units of Orthofix MINIRAIL orthopedic external fixation devices distributed across the US due to incorrect model labeling that could lead to surgical use of the wrong device.

    Product
    Orthofix MINIRAIL, SHORT, LENGTHENER REF: M103, Unilateral orthopedic/trauma external fixation device
    Category
    Medical Device
    Distribution
    26 states
  • HighFDA (Devices)·Z-2725-2026·2026-07-22

    Rapid Refill Continuous Injection System Recalled for Syringe Loosening Risk

    Boston Scientific's Rapid Refill Continuous Injection System (UPN M00566001) is being recalled because the recalled Medline Namic Angiographic Control Syringe may loosen or disconnect from the manifold, potentially causing leakage, inability to aspirate or inject, and procedure delays.

    Product
    Rapid Refill Continuous Injection System, UPN M00566001
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2728-2026·2026-07-22

    Mobile Digital Radiographic System Arm Drop Risk During Patient Exams

    GE HealthCare is recalling certain Optima XR200/220/240amx Mobile Digital Radiographic Systems due to potential failure of the Column Safety mechanism, which could cause the X-ray arm to drop during patient exams. The issue stems from incomplete functional testing of the safety pawl after column replacement.

    Product
    Optima XR240amx, Mobile Digital Radiographic System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2726-2026·2026-07-22

    GE Medical Optima XR200/220/240amx Mobile Radiographic Systems Recall

    GE HealthCare recalls certain Optima XR200/220/240amx mobile radiographic systems where safety testing may have been incomplete after column replacement. A failed counterpoise cable could cause the X-ray arm to drop on patients.

    Product
    Optima XR200amx, Mobile Digital-Ready Radiographic System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2737-2026·2026-07-22

    Medline Kits with Zimmer Biomet Mixing Bowls and Spatulas Recalled

    Medline Industries is recalling 163 kits containing Zimmer Biomet mixing bowls and spatulas due to seal defects that risk sterility breach during surgical procedures.

    Product
    Medline Kits containing Zimmer Biomet mixing bowls and spatulas TOTAL KNEE PACK-LF DYNJ61651J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2733-2026·2026-07-22

    Papablic Replacement Brush Heads Recalled for Potential Breakage

    Papablic Inc is recalling certain Papablic18B replacement brush head packs because the brush heads may break during use.

    Product
    Papablic Replacement Brush Heads. Model Number: Papablic18B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2722-2026·2026-07-22

    da Vinci SP Instrument Arm Drape may detach during surgical procedures

    Intuitive Surgical is recalling da Vinci SP Instrument Arm Drapes because the drape rings may detach, exposing the instrument arm and potentially delaying procedures. The recall affects 11,113 units distributed worldwide.

    Product
    da Vinci SP Instrument Arm Drape, SP, 1-PACK, Part Number: 430013-13, 430013-15
    Category
    Medical Device
    Distribution
    Distributed nationwide