The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

8801–8825 of 40095

  • SevereFDA (Devices)·Z-0194-2024·2023-11-15

    FDA Recalls Olympus EVIS EXERA III Bronchovideoscope for Combustion Risk

    Olympus Corporation is recalling 3,948 EVIS EXERA III bronchovideoscope units nationwide due to risk of combustion during electrosurgical procedures when high-frequency cauterization is used with oxygen supply.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE OLYMPUS Model Number BF-P190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0190-2024·2023-11-15

    Olympus Bronchovideoscope Recall for Combustion Risk with Electrosurgery

    Olympus is recalling 1,154 EVIS EXERA II bronchovideoscope units due to risk of endobronchial combustion during high-frequency electrosurgical procedures when oxygen is supplied and electrode placement is inappropriate.

    Product
    EVIS EXERA II BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Number Q180-AC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0184-2024·2023-11-15

    Alaris PCA Module 8120 infusion pump recalled for unvalidated syringes

    CareFusion 303, Inc. is recalling the Alaris PCA Module 8120 infusion pump because its labeling lists compatible syringes that have not been validated. This Class I recall affects 867,362 units worldwide.

    Product
    BD Alaris PCU REF 8015
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0193-2024·2023-11-15

    Olympus Bronchovideoscope Recalled Due to Combustion Risk

    Olympus is recalling 719 EVIS EXERA b Bronchovideoscope Model BF-XT190 devices due to risk of endobronchial combustion during high-frequency cauterization when oxygen is supplied or the electrode is too close to the device tip.

    Product
    EVIS EXERA b BRONCHOVIDEOSCOPE OLYMPUS Model Number BF-XT190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0151-2024·2023-11-15

    Novum IQ Syringe Pump may falsely indicate infusion completion

    Baxter's Novum IQ Syringe infusion system may display a false 'Infusion Complete' alarm after multiple occlusion events, leaving uninfused fluid in the syringe and risking incomplete medication delivery.

    Product
    Novum IQ Syringe infusion system, Product Code 40800BAXUS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0286-2024·2023-11-15

    Cordis Cardiac Catheter Sets Distributed Non-Sterile, Labeled Sterile

    Cordis US Corp is recalling cardiac catheter sets (Lot 18223410) distributed in Oklahoma. The devices were non-sterile but labeled as sterile, creating infection risk to patients.

    Product
    Cordis ANGIOGRAPHIC CATHETERIZATION SETS, INFINITI THRULEMEN, 5F, REF CO0208, cardiac catheter
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0191-2024·2023-11-15

    Olympus Bronchovideoscope Recalled for Fire Risk During Cauterization

    Olympus Corporation recalls 13,950 EVIS EXERA II bronchovideoscopes due to risk of endobronchial combustion when high-frequency cauterization is performed with oxygen supplied while the electrode is positioned too close to the endoscope.

    Product
    EVIS EXERA II BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Numbers BF-1T180, BF-1TQ180, BF-P180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0192-2024·2023-11-15

    Olympus Bronchovideoscopes Recalled for Endobronchial Combustion Risk

    Olympus is recalling bronchovideoscopes nationwide due to a risk of combustion inside the bronchial passages during high-frequency cauterization if oxygen is supplied or the electrode is positioned too close to the scope's tip.

    Product
    EVIS EXERA III BRONCHOVIDEOSCOPE Model Numbers BF-1TH190, BF-H190, BF-Q190 and BRONCHOVIDEOSCOPE OLYMPUS BF-Q170 Model Number BF-Q170
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0188-2024·2023-11-15

    StealthStation S8 Surgical Navigation System Software Anomaly Recall

    Medtronic is recalling StealthStation S8 and FlexENT systems with software versions 2.0 and 2.0.1 due to a software anomaly that could cause surgical planning data to shift to an unintended location.

    Product
    StealthStation S8 Application version 2.0 and 2.0.1 (Part 9735762) The StealthStation System, with StealthStation Cranial software, is intended as an aid for locating anatomical structures in either open or percutaneous neurosurgical procedures. The StealthStation FlexENT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0189-2024·2023-11-15

    Five Olympus Bronchovideoscope Models Recalled for Endobronchial Combustion Risk

    Olympus is recalling 15,942 bronchovideoscope units nationwide due to endobronchial combustion risk during cauterization procedures with oxygen supply. The hazard occurs when the electrode of the surgical accessory is positioned too close to the scope's distal end.

    Product
    BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Numbers BF-1T150, BF-1T60, BF-P150 BF-P60 and EVIS EXERA BRONCHOVIDEOSCOPE OLYMPUS BF TYPE Model Number XT160
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0249-2024·2023-11-15

    Stryker Bipolar Forceps Recalled for Incorrect Expiration-Date Labeling

    Stryker Corporation is recalling 2,321 Disposable Spetzler-Malis Bipolar forceps due to incorrect shelf-life labeling. Products labeled with 54-month shelf life actually have a 36-month shelf life.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 20CM IM DISP BAYONET 1.5MM TIP, Catalog Number 6770-200-015
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0284-2024·2023-11-15

    Philips Affiniti 70 Ultrasound System Software Defect May Cause Delayed Images

    Philips is recalling 7 Affiniti 70 diagnostic ultrasound systems with software version 10.0 due to a defect that may produce delayed imaging instead of real-time images.

    Product
    Philips Affiniti 70, Diagnostic Ultrasound System Model # 795210
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-0231-2024·2023-11-15

    Breg Folding Walkers With Wheels Recalled for Misaligned Wheels

    Breg Inc is recalling 11,193 folding walkers with misaligned wheels that do not meet product specifications. The defect could affect stability and increase fall risk.

    Product
    BREG REF 100519-000 WALKER FOLDING WALKER WITH WHEELS Utilized as a walking aid.
    Category
    Medical Device
    Distribution
    41 states
  • HighFDA (Devices)·Z-0133-2024·2023-11-15

    Medical administration set for radiation therapy recalled due to leakage risk

    B. Braun Medical recalls THERASPHERE ADMIN SET due to manufacturing defects causing potential leakage. Leakage may delay therapy, increase bloodstream infection risk, and expose patients and healthcare workers to hazardous medication.

    Product
    THERASPHERE ADMIN SET, Article No. 7M2650. Canada only. Sterile, single use administration set used to deliver Yttrium-90 glass microspheres for internal radiation therapy.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0128-2024·2023-11-15

    B. Braun FT1000S Fluid Transfer Sets may leak, risking infection

    B. Braun is recalling FT1000S Fluid Transfer Sets due to a manufacturing defect that may cause leakage. This could delay therapy, increase infection risk, and expose healthcare workers to hazardous medication.

    Product
    FT1000S FLUID TRANSFER SET, REF No. 356048. For direct transfer of fluids between large volume parenteral solution containers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0258-2024·2023-11-15

    DJO EMPOWR Knee Punch Handle Tip May Break During Surgery

    Encore Medical is recalling DJO EMPOWR Knee Punch Handles due to a manufacturing defect that may cause the handle tip to break during surgery, potentially disrupting the procedure.

    Product
    DJO EMPOWR Knee Punch Handle, REF: 801-05-040
    Category
    Medical Device
    Distribution
    24 states
  • HighFDA (Devices)·Z-0224-2024·2023-11-15

    Philips surgical imaging systems missing warning label and safety spacer

    Philips has recalled certain surgical C-arm imaging systems delivered to Puerto Rico because they lack required warning labels and are missing a critical Source-to-Skin Distance Spacer component.

    Product
    BV Endura, BV Pulsera Philips Image Guided Therapy-Systems (IGTS)Mobile Surgery C-arm systems.
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0259-2024·2023-11-15

    Monitron II Waveform Analyzer Screen Freeze Defect in Ventilator Models

    Percussionaire Corporation recalled 212 Monitron II Waveform Analyzers due to screen freeze issues on visual displays. Affected units were serviced with PAL microprocessor chips and firmware updates.

    Product
    Monitron II Waveform Analyzer, REF: S00015-1, used with ventilators.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-0226-2024·2023-11-15

    Surgical C-arm systems recalled for missing warning label and spacer

    Philips is recalling Zenition 50 & 70 surgical C-arm systems distributed to Puerto Rico, Guam, and the Virgin Islands due to missing warning labels and safety spacers. These missing components may compromise radiation safety during surgical use.

    Product
    Zenition 50 & 70 Mobile Surgery C-arm
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0290-2024·2023-11-15

    Medical device blood oxygenation system recalled due to defective weld

    Maquet Medical Systems USA is recalling 1,022 Cardiohelp-i blood oxygenation systems due to an insufficient weld on a critical component that may break under manual force.

    Product
    Cardiohelp-i, blood oxygenation and carbon dioxide removal system, Part Numbers 701072780 (Cardiohelp-i), 701068550 (Slide Rail Holder)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0136-2024·2023-11-15

    IV Fitting Components Recalled Due to Manufacturing Defect and Leakage Risk

    B. Braun Medical is recalling 175,000 units of bulk largebore male LL fittings due to a manufacturing defect that may cause leakage, potentially increasing bloodstream infection risk.

    Product
    BULK LARGEBORE MALE LL FITTING, Article No. M4341750SN. IV administration component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0243-2024·2023-11-15

    Stryker disposable surgical forceps recalled for incorrect expiration date labeling

    Stryker Corporation is recalling 2,321 Spetzler-Malis bipolar surgical forceps due to incorrect expiration date labeling. The product label states a 54-month shelf life when the actual shelf life is only 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 23CM SM DISP BAYONET 1.0MM TIP, Catalog Number 6760-230-010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0239-2024·2023-11-15

    Disposable Spetzler-Malis Bipolar Forceps Recalled for Incorrect Shelf Life Label

    Stryker is recalling 2,321 disposable Spetzler-Malis Bipolar forceps due to a labeling error showing an incorrect shelf life. The product label indicates 54 months, but the actual shelf life is 36 months.

    Product
    Disposable Spetzler-Malis Bipolar forceps, 18CM SM DISP BAYONET 0.5MM TIP, Catalog Number 6760-180-005
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.