The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

6651–6675 of 13666

  • HighFDA (Devices)·Z-1687-2024·2024-05-01

    Water bottles used in dental treatment devices recalled for disassembly risk

    Electro Medical Systems is recalling water bottles used with AIRFLOW dental devices because certain bottle collars can disassemble under pressure during treatment or storage. No injuries have been reported.

    Product
    Brand Name: WATER BOTTLE Product Name: WATER BOTTLE Model/Catalog Number: EG-121 Software Version: N/A Product Description: These bottles are sold empty and are filled by the user with water fort dental treatments. The bottle is pressurized on the device during use. Componen
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1618-2024·2024-05-01

    Replacement Lead Wires Recalled for Risk of Treatment Delivery Failure

    EBI, LLC recalls 829 replacement lead wire assemblies (Part 1067724-2) distributed nationwide since May 1, 2023. Damaged wire sheaths may prevent therapeutic treatment signals from reaching electrodes, potentially delaying treatment.

    Product
    20" Lead Wires, Replacement Part Number: 1067724-2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1620-2024·2024-05-01

    Pedicle Screw Heads Recalled Due to Cross-Threading Risk During Surgery

    SeaSpine's Mariner RDX MIS pedicle screw heads may have partial threading that causes cross-threading at the screw head interface during implant installation. Affected units distributed in CA, FL, CO, and TX.

    Product
    Mariner RDX MIS Polyaxial Head, REF: MX1-001010, part of Mariner RDX MIS Alpha Instruments and Implants, REF: AMRDXMIS, which are pedicle screw systems.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1630-2024·2024-05-01

    Hip prosthesis shells recalled for manufacturing deburring defect

    Howmedica Osteonics Corp. is recalling TRIDENTII PSL CLUSTER52E hip prostheses with excessive deburring on the acetabular shell edge, which could affect implant stability. Three units were distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER52E- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-52E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1628-2024·2024-05-01

    Hip implant recalled for acetabular shell deburring defect

    Howmedica Osteonics Corp. is recalling TRIDENTII PSL CLUSTER48D hip implants (Lot 16311453) due to excessive deburring on the acetabular shell edge, a manufacturing defect.

    Product
    TRIDENTII PSL CLUSTER48D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-48D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1606-2024·2024-05-01

    Alcon Custom Paks Surgical Procedure Packs recalled for cannula defects

    Alcon is recalling Custom Paks Surgical Procedure Packs containing Oasis 27Ga Chang Hydrodissection Cannulas due to complaints of particulates, residue, occlusions, and bent tips in sterile cannulas used in ophthalmic surgery.

    Product
    Various Alcon Custom Paks Surgical Procedure Pack containing Oasis 27Ga Chang Hydrodissection Cannulas. These Custom Paks are surgical procedure packs used by ophthalmic surgeons in a variety of ophthalmic surgeries. The Custom Pak is a collection of various ophthalmic surgical
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1599-2024·2024-05-01

    ACUSON Juniper ultrasound systems display incorrect cardiac measurements

    Siemens ACUSON Juniper ultrasound systems may display the wrong cardiac measurement value when configured to show minimum or maximum values, potentially leading to misdiagnosis.

    Product
    ACUSON Juniper Diagnostic Ultrasound System, REF: 11335791, and ACUSON Juniper Select Diagnostic Ultrasound System, REF: 11653093, running software version VA10x with DICOM SR Cardiac option, from VB10A to VB10G, VB11A, VB11B, VB30B and VB30C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1686-2024·2024-05-01

    Cleaner Bottles May Disassemble Under Pressure During Treatment

    EMS CLEANER BOTTLES (Model EG-1000) for dental prophylaxis systems may disassemble under pressure during treatment or storage. FDA Class II recall; no injuries reported.

    Product
    Brand Name: CLEANER BOTTLE Product Name: CLEANER BOTTLE Model/Catalog Number: EG-1000 Software Version: N/A Product Description: CLEANER bottles used with EMS AIRFLOW PROPHYLAXIS MASTER / EMS AIRFLOW ONE devices to clean the water lines. The bottle is placed on the device du
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1632-2024·2024-05-01

    Hip replacement acetabular shells recalled for deburring defect

    Howmedica is recalling hip replacement acetabular shells that may have excessive deburring, resulting in a smooth surface on the shell edge. The recall affects devices distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER64H- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-64H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1690-2024·2024-05-01

    Philips Patient Information Center iX UPS devices recalled for potential power failure

    Philips is recalling certain Patient Information Center iX Uninterruptable Power Supply devices due to potential power supply failures that could cause the monitoring system to shut down, risking delays in detecting patient condition changes.

    Product
    Philips Patient Information Center (PIC) iX Uninterruptable Power Supply (UPS): 1. APC (Schneider Electric IT Corporation) 120V Uninterruptable Power Supply Model: SCL500RM1U 2. APC (Schneider Electric IT Corporation) 230V Uninterruptable Power Supply Model: SCL500R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1622-2024·2024-05-01

    TRIDENTII HEMI hip implant recalled for acetabular shell manufacturing defect

    Howmedica Osteonics is recalling the TRIDENTII HEMI CLUSTER48D hip implant because the acetabular shell may have excessive deburring, resulting in a smooth surface on the shell edge.

    Product
    TRIDENTII HEMI CLUSTER48D-indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-48D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1602-2024·2024-05-01

    Abbott Alinity m System camera generates error with certain tubes

    Abbott Molecular is recalling 1,012 Alinity m System units due to a camera detection issue that generates an error message when certain third-party transport medium tubes lack a sample rack retention bar.

    Product
    Alinity m System, Part Number: 08N53-002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1623-2024·2024-05-01

    Hip Implant Acetabular Shell Recalled for Manufacturing Defect

    Howmedica Osteonics is recalling TRIDENTII HEMI CLUSTER50D hip implant shells due to excessive deburring that may create a smooth edge, potentially affecting implant fit. Affected units were distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER50D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-50D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1616-2024·2024-05-01

    Spine Fusion Stimulator Recalled for Damaged Lead Wire Sheath

    The Biomet SpinalPak Spine Fusion Stimulator System is recalled for potential lead wire sheath damage that may prevent delivery of the therapeutic treatment signal. Devices distributed nationwide since May 2023 are affected.

    Product
    Biomet SpinalPak Non-invasive Spine Fusion Stimulator System- Indicated for the treatment of an established nonunion acquired secondary to trauma, excluding vertebrae and all flat bones, Part Number: 1067716
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1688-2024·2024-05-01

    PIEZON Bottle May Disassemble Under Pressure During Dental Use

    FDA recalls PIEZON Bottle (Model EG-111) dental treatment bottles because certain units may separate into two parts when pressurized during treatment or storage. No injuries have been reported.

    Product
    Brand Name: PIEZON Bottle Product Name: PIEZON Bottle Model/Catalog Number: EG-111 Software Version: N/A Product Description: These bottles are sold empty and are filled by the user with water - in some cases small quantities of disinfectant solutions - for dental treatments.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1617-2024·2024-05-01

    Biomet OrthoPak Bone Growth Stimulator System Recalled Due to Lead Wire Damage

    The Biomet OrthoPak Bone Growth Stimulator System is being recalled due to potential lead wire sheath damage that could prevent therapeutic signal delivery and delay patient treatment nationwide.

    Product
    Biomet OrthoPak Non-invasive Bone Growth Stimulator System-Indicated for the treatment of an established nonunion acquired secondary to trauma, excluding vertebrae and all flat bones. Part Number: 1067718
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1604-2024·2024-05-01

    Redux Electrolyte Creme Recalled for Low Viscosity Defect

    Parker Laboratories is recalling Redux Electrolyte Creme, a highly conductive medical electrolyte product, due to demonstrated low viscosity.

    Product
    Redux Electrolyte Creme, Product Ref. 66-04. Highly conductive electrolyte creme.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1608-2024·2024-05-01

    NexGen CR-Flex Femoral Components Recalled for Bonding Defect

    Zimmer is recalling 5,546 units of NexGen CR-Flex Femoral Components due to a manufacturing defect where the fiber metal pad fails to bond properly to the substrate. Patients with these implants should contact their healthcare provider.

    Product
    NexGen CR-Flex Femoral Component, Size E and Size E Minus (E-). Component of the NexGen CR-Flex Porous Femur System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1625-2024·2024-05-01

    TRIDENTII HEMI Hip Implant Acetabular Shell Deburring Defect Recall

    Howmedica Osteonics is recalling the TRIDENTII HEMI CLUSTER54E hip implant due to excessive deburring on the acetabular shell edge that may affect implant performance. The recall involves 225 units distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER54E- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-54E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1621-2024·2024-05-01

    Hip implant acetabular shell manufacturing defect recall affects patients

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER44B hip implants due to excessive deburring on the acetabular shell edge. The recalled lot was distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER44B- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-44B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1627-2024·2024-05-01

    Hip Implant Acetabular Shell May Have Excessive Deburring Manufacturing Defect

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER66H hip implants because the acetabular shell may have excessive deburring, creating a smooth surface on the edge of the shell.

    Product
    TRIDENTII HEMI CLUSTER66H- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-66H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1635-2024·2024-05-01

    Palindrome Precision H Chronic Catheter Kit may lack labeled heparin coating

    Covidien is recalling 878 units of Palindrome Precision H Chronic Catheter Kits that may lack the heparin anticoagulant coating indicated on the label, potentially reducing clot prevention during hemodialysis.

    Product
    Palindrome Precision H Chronic Catheter Kit 14.5 Fr/Ch (4.8mm) x 23 cm (Symmetrical Tip, Heparin Coating and Tal VenaTrac Stylet- Intended for acute and chronic hemodialysis, apheresis, and infusion. Model Number (CFN): 8888145044CP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1629-2024·2024-05-01

    Hip replacement acetabular shell recalled for excessive deburring

    Howmedica Osteonics is recalling TRIDENTII PSL CLUSTER50D acetabular shells for hip replacements due to excessive deburring resulting in smooth edges on the shell.

    Product
    TRIDENTII PSL CLUSTER50D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-50D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1607-2024·2024-05-01

    Vanguard Knee System Tibial Bearing Recalled for Manufacturing Damage

    Biomet is recalling the Vanguard Knee System AS Tibial Bearing (Model 189082) due to possible damage during manufacturing. Affected units were distributed worldwide including the United States.

    Product
    Vanguard Knee System AS Tibial Bearing / DCM ArCom, 12 MM X 75 MM; Model Number 189082. The product is placed into a foil pouch with protective packaging in the form of a polyurethane bag, and sealed closed (inner barrier). The inner barrier is then placed into a PETG tray and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1600-2024·2024-05-01

    ACUSON Redwood 1.0 ultrasound displays incorrect cardiac measurement values

    The ACUSON Redwood 1.0 Diagnostic Ultrasound System may display the last measured cardiac value instead of the minimum or maximum value as configured, potentially leading to misdiagnosis or improper patient management.

    Product
    ACUSON Redwood 1.0 Diagnostic Ultrasound System, REF: 11503314, running software version VA10A to VA10G
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.