The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

6451–6475 of 13526

  • HighFDA (Devices)·Z-1751-2024·2024-05-08

    RayStation radiation therapy planning system may report inaccurate dosimetry values

    RayStation 14.0.0.3338, a radiation therapy treatment planning system, may report source-to-surface distance (SSD) values as higher than actual measurements, potentially affecting radiation dose calculations. The FDA Class II recall involves 49 units distributed worldwide.

    Product
    RayStation 14.0.0.3338. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1738-2024·2024-05-08

    Jackson-Pratt Drainage Kits Shipped Unsterilized in Voluntary Removal

    Cardinal Health is voluntarily removing Jackson-Pratt drainage kits (Lot 210751D6) that were shipped without sterilization. The unsterilized devices pose an infection risk if used in patient care.

    Product
    Jackson-Pratt Universal Connector PVC Tubing Anti Reflux Transparent Y, REF SU130-4601
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1745-2024·2024-05-08

    Radiation therapy planning system dose calculation error

    RayStation versions 9.1.0.933 and 9.2.0.483 may incorrectly calculate dose parameters. 11 units of this radiation therapy treatment planning software were distributed worldwide.

    Product
    RayStation 9.1.0.933 and 9.2.0.483. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1731-2024·2024-05-08

    Medtronic Invos Infant Sensor Cables recalled for manufacturing defects

    Covidien is recalling 1,122 Medtronic Invos Reusable Infant Sensor Adapter Cables due to manufacturing defects in connectors. The defects may cause error codes or non-functioning monitoring channels.

    Product
    Medtronic Invos, Reusable Infant Sensor Adapter Cable for PM7100, REF: PMAC71RIC
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-1707-2024·2024-05-08

    Zirconium Oxide Dental Restoration Blocks Recalled for Potential Cracking

    IVOCLAR VIVADENT is recalling IPS e.max ZirCAD zirconium oxide dental blocks nationwide due to defective units that may crack during sintering and cause dental restoration fracture.

    Product
    IPS e.max ZirCAD CER/in. Prime B1 C17/5 -A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth. Article Number: 758441
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1755-2024·2024-05-08

    Johnson & Johnson Irrigation Sleeve Recalled for Manufacturing Defect

    Johnson & Johnson is recalling 3,428 reusable irrigation sleeves due to manufacturing defects that could impair cooling during eye surgery, potentially causing anterior chamber instability and patient harm.

    Product
    Johnson & Johnson VISION Reusable LAMINAR High Flow Irrigation Sleeve and Test Chamber 21 Gauge REF OPOHF21L The irrigation sleeve is a device intended to direct irrigation solution across the shaft of a phacoemulsification tip, allowing the solution to enter the eye during
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1716-2024·2024-05-08

    Zimmer Locking Plate System Recalls Distal Fibular Plates Due to Thread Defect

    Zimmer recalls distal fibular plates with defective locking holes that may prevent proper screw fixation during orthopedic surgery, potentially requiring additional intervention.

    Product
    ZPLP(Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Left, 6 Holes, 106 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-018-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1711-2024·2024-05-08

    Zimmer Periarticular Locking Plate threading defect may compromise surgical fixation

    Zimmer's Periarticular Locking Plate System may have defective threads in locking holes, preventing secure screw mating. The defect could result in loss of surgical stability and require additional surgery.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 8 Holes, 132 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1749-2024·2024-05-08

    Radiation therapy planning system doses may be calculated incorrectly

    Certain versions of RayStation radiation therapy planning software may incorrectly report dose-related parameters, potentially affecting treatment calculations. The manufacturer recommends verification of affected systems.

    Product
    RayStation 12.0.0.932, 12.1.0.1221, 12.0.3.68, 12.0.4.12 &12.3.0.119. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1714-2024·2024-05-08

    Zimmer Locking Plate System recalled due to thread mating defect

    Zimmer is recalling the ZPLP Distal Lateral Fibular Plate due to a thread form defect in the locking holes. Locking screws may not properly mate with the plate, potentially causing surgical delay or loss of fixation.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 16 Holes, 236 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-16
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1712-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate Locking Screw Defect

    Zimmer's Periarticular Locking Plate may have defective locking holes that prevent screws from properly locking, risking loss of bone fixation and requiring additional surgery.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 10 Holes, 158 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1728-2024·2024-05-08

    Zimmer Fibular Plate Recall: Locking Hole Thread Form Defect

    Zimmer is recalling certain ZPLP Distal Lateral Fibular Plates due to a thread form issue in the locking holes. Improperly mating screws may not correctly lock, potentially resulting in loss of fixation and need for additional surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 8 Holes, 132 MM, Nonsterile-Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-08
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1736-2024·2024-05-08

    Unsterilized Jackson-Pratt surgical drain kits recalled by Cardinal Health

    Cardinal Health recalls Jackson-Pratt 3-Spring Reservoir Kits because specific lots were shipped before sterilization. Unsterilized surgical devices pose risk of infection.

    Product
    Jackson-Pratt 3-Spring Reservoir Kit with PVC Round Drain, 400mL, 10Fr., REF SU130-402D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1734-2024·2024-05-08

    Galaxy System Wired Controller Recalled for Unintended Scope Motion

    Noah Medical recalls 17 Galaxy System wired controllers (Model GAL-019) due to calibration misalignment that may cause unintended scope motion during bronchoscopic procedures.

    Product
    Galaxy System REF GAL-001 (specifically GAL-019, Wired Controller) The Galaxy System and its accessories are intended to provide bronchoscopic visualization of and access to patient airways for diagnostic and therapeutic procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1744-2024·2024-05-08

    Radiation Therapy Planning System May Report Dose Values Too High

    RayStation radiation therapy planning software versions 9.0.0.113 and 9.0.1.142 may report dose values that are higher than actual. The Class II recall affects 63 units distributed worldwide.

    Product
    RayStation 9.0.0.113 and 9.0.1.142. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1729-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate Recall Due to Locking Thread Defect

    Zimmer recalls certain ZPLP Distal Lateral Fibular Plates due to thread form defects in locking holes that may prevent proper screw fixation. Affected devices may lose fixation, potentially delaying surgery or requiring additional intervention.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 10 Holes, 158 MM, Nonsterile-Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-10
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1726-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plates May Have Improper Screw Locking

    A thread form defect in the locking holes of Zimmer surgical bone plates may prevent locking screws from securing properly, potentially causing loss of fixation during surgery.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 4 Holes, 80 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1703-2024·2024-05-08

    Zirconium Oxide Dental Blocks Recalled Due to Fracture Risk

    IVOCLAR VIVADENT AG is recalling 2,286 units of zirconium oxide blocks used for dental restorations because defective units may develop cracks during processing, potentially causing restorations to fracture in patients' mouths.

    Product
    IPS e.max ZirCAD CER/in. Prime BL1 C17/3- A zirconium oxide block for the fabrication of fixed, full-contour restorations in anterior and posterior teeth. Article Number: 758434
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1727-2024·2024-05-08

    Zimmer Fibular Plate Recall: Defective Locking Hole Threading

    Zimmer, Inc. is recalling ZPLP Distal Lateral Fibular Plates due to defective threading in the locking holes. The screws may not properly engage with the plate, potentially causing surgical delays or loss of bone fixation.

    Product
    ZPLP Distal Lateral Fibular Plate, Left, 6 Holes, 106 MM, Nonsterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 00-2357-018-06
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1713-2024·2024-05-08

    Zimmer Periarticular Locking Plate screw-mating defect risks surgical fixation loss

    Zimmer's Periarticular Locking Plate System has a thread defect that may prevent proper screw locking, potentially causing loss of surgical fixation. Affected units distributed worldwide.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 12 Holes, 184 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-12
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1750-2024·2024-05-08

    RayStation Radiation Therapy System Recalled for Potential Dosing Error

    RayStation versions 13.0.0.1547, 13.1.0.144, and 13.1.1.89 radiation therapy treatment planning systems are recalled due to a potential software error in source-to-surface distance calculations that could affect radiation dose delivery.

    Product
    RayStation 13.0.0.1547, 13.1.0.144 & 13.1.1.89. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1702-2024·2024-05-08

    Abbott Cholestech LDX Battery Kit Recall: Potential Swelling Risk

    Abbott is recalling the Cholestech LDX Battery Kit due to a potential for battery swelling that could cause minor burns, cuts, abrasions, or electrical shock to users.

    Product
    Abbott Cholestech LDX Battery Kit, Model: 3LP656194-PCM-LD, PN: 55170
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1743-2024·2024-05-08

    RayStation radiation therapy planning software affected by source-to-surface distance calculation error

    RayStation radiation therapy treatment planning software versions 8.1.0.47, 8.1.1.8, and 8.1.2.5 may calculate source-to-surface distance incorrectly, potentially affecting dose calculations. Approximately 5 units are distributed worldwide.

    Product
    RayStation 8.1.0.47, 8.1.1.8 and 8.1.2.5. Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1756-2024·2024-05-08

    Philips Spectral CT Oncology Imaging System Recall: Laser Reflection Hazard

    Philips recalls 12 units of its Spectral CT Oncology Essentials system because a marking laser could reflect off the gantry cover, potentially causing misdiagnosis and incorrect patient treatment.

    Product
    The Oncology Essentials Package of the Spectral CT imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.