About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

38851–38875 of 40489

  • HighFDA (Devices)·Z-0947-2013·2013-03-20

    GE Healthcare Recalls Cardiovascular X-ray Systems Due to Locking Nut Issue

    GE Healthcare is recalling specific cardiovascular X-ray imaging systems because a locking nut on the overhead video monitor suspension might loosen.

    Product
    GE Healthcare Advantx, Innova2000, Innova3100, Innova4100, Innova2100IQ, Innova3100IQ, and Innova4100IQ equipped with Video Monitor Suspension Cardiovascular X-ray imaging systems. Model numbers 2236709, 2353620 ,2223039-2, and 2270677-2.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0930-2013·2013-03-20

    Siemens ACUSON S2000 ABVS Scanner Recalled for Sharp Transducer Edges

    Siemens is recalling 214 ACUSON S2000 ABVS systems because the transducer pod may contain sharp edges that could cause injury.

    Product
    ACUSON S2000 Automated Breast Volume Scanner (ABVS); Model number 10042541 Distributed by Siemens Medical Solutions USA Inc. business Unit: Ultrasound. The S2000 Automated Breast Volume Scanner (ABVS) Ultrasound System for imaging of the breast allows volumetric…
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0919-2013·2013-03-20

    Stryker Howmedica Command Instrument Broach Handle Recalled for Fracture Risk

    Stryker Howmedica is recalling 48 Command Instrument Broach Handles used in hip surgery due to reports of handle fracture and component disassociation.

    Product
    Command Instrument Broach Handle. Used in Total Hip Arthroplasty. Catalog Number: 6266-0-100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0922-2013·2013-03-20

    Instratek Recalls Endotrig Trigger Release Blades Due to Cannula Advancement Issues

    Instratek is recalling 235 Endotrig Trigger Release Sterile Micro Hook Blades because they could not be advanced into the cannula during procedures.

    Product
    Endotrig Trigger Release Sterile Micro Hook Blade Product Usage: The blade is intended to release A-1 pulley in endoscopic trigger release procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0938-2013·2013-03-20

    Synthes Spine Pedicle Screw Recalled for Incorrect Length Etching

    Synthes USA HQ, Inc. is recalling 18 units of 45 mm Click 'X Pedicle Screws because they were incorrectly etched as 40 mm.

    Product
    Synthes Spine 5.2mm Titanium Click ' X Pedicle Screw Dual Core 40 mm Thread Length, Part Number 487.072. Intended to provide precise and segmental stabilization of the spine in skeletally mature patients.
    Category
    Medical Device
    Distribution
    7 states
  • ModerateFDA (Devices)·Z-0932-2013·2013-03-20

    Spine Smith Partners Recalls Cynch Lordotic T-PLIF Implants Due to Marking Error

    Spine Smith Partners LP is recalling three Cynch Lordotic T-PLIF implants distributed in Texas because they were incorrectly laser marked as 23mm instead of 28mm.

    Product
    Cynch Lordotic T-PLlF Implant. Intervertebral fusion device with bone graft, for use with supplemental fixation.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0951-2013·2013-03-20

    Diagnostica Stago Recalls LIATEST VWF:Ag Coagulation Assay Kits

    Diagnostica Stago is recalling LIATEST VWF:Ag kits because measurement errors may lead to lowered percentage results.

    Product
    Vial Label: 1) LIATEST VWF:Ag Buffer - 5 ml Diagnostica Stago 2) LIATEST VWF:Ag Latex + 4 ml R3 Diagnostica Stago 3) LIATEST VWF:Ag Latex Diluent 4 mL Diagnostica Stago Model, catalogue, number 00518 - 58978 - 58979 Kit Label: LIATEST VWF:Ag DIAGNOSTICA STAGO…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0941-2013·2013-03-20

    Synthes Large Combination Clamp Recalled Due to Oversized Hex Nuts

    Synthes USA is recalling 136 Large Combination Clamps because oversized hex nuts prevent standard 11 mm sockets and wrenches from fitting.

    Product
    Large Combination Clamp/Large External Fixation System, Part Number 390.005 Product Usage: Synthes Large External Fixation is intended for use to provide treatment for long bone and pelvic fractures that require external fixation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0950-2013·2013-03-20

    Philips Brilliance 64 and Ingenuity CT Systems Software Update Recall

    Philips Medical Systems is recalling 42 Brilliance 64 and Ingenuity CT systems to update software and customer release notes.

    Product
    Brilliance 64 and Ingenuity Computed Tomography X-Ray Systems The Brilliance 64 and Ingenuity CT are whole body Computed Tomography X-Ray Systems intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data taken at different…
    Category
    Medical Device
    Distribution
    19 states
  • ModerateFDA (Devices)·Z-0942-2013·2013-03-20

    Synthes Titanium Midface Distractor Recalled Due to Fit Issues

    Synthes USA is recalling 596 Titanium Midface Distractors because oversized tabs may prevent footplates from fitting properly.

    Product
    Synthes Titanium Midface Distractor, MR Conditional, Part number 487.982. For temporary stabilization and gradual lengthening of the cranial or midfacial bones.
    Category
    Medical Device
    Distribution
    5 states
  • ModerateFDA (Devices)·Z-0935-2013·2013-03-20

    GE Healthcare Recalls MRI Systems Due to Reporting Tool Error

    GE Healthcare is recalling multiple MRI systems because an error in the SR Viewer Reporting Tool allows edits to be saved to incorrect reports.

    Product
    Optima MR450w, Discovery MR450, Discovery MR750, Signa HDx, Signa HDxt, Signa HDi, Signa Vibrant, and GE 1.5T Signa HDe MR System. The GE Signa HDx MR system is a whole body magnetic resonance scanner.
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Devices)·Z-0937-2013·2013-03-20

    Vygon Recalls 210 CT PICC Kits Packaged with Incorrect Needles

    Vygon Corporation is recalling 210 units of 6F Triple Lumen CT PICC kits because they were packaged with non-safety needles instead of the safety needles indicated on the label.

    Product
    Churchill Medical Systems, Inc. A Vygon Company - All sizes of CMS-CT6T225 6F Triple Lumen CT PICC with M.S.T. Components, Peripherally Inserted Central Catheter.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0944-2013·2013-03-20

    Smith & Nephew Recalls Mislabelled Trigen Internal Hex Reconstruction Screws

    Smith & Nephew is recalling 90 units of Trigen internal hex reconstruction screws because 75 mm and 80 mm lengths were packaged in incorrect boxes and labels.

    Product
    INTERNAL HEX RECON SCREW, TI-6AL-4V, REF 7162375, TRIGEN (R) INTERNAL HEX CAPTURED RECON SCREW, QTY: (1), 6.4 MM, 75 MM, TITANIUM, Smith & Nephew, Inc. Orthopedic. Bone screw for intramedullary rod fixation.
    Category
    Medical Device
    Distribution
    11 states
  • ModerateFDA (Devices)·Z-0925-2013·2013-03-20

    Biomet Recalls Straight Acetabular Inserter Handles Due to Latch Interference

    Biomet, Inc. is recalling 58 non-sterile Straight Acetabular Inserter Handles because they may lock onto the cup during surgery, potentially causing delays.

    Product
    REF S313152 Straight Acetabular Inserter Handle Ringloc non-sterile Orthopedic manual surgical instrument
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0948-2013·2013-03-20

    Siemens CT Software Recall for Sporadic 3D Reconstruction Hang-Ups

    Siemens Medical Solutions is recalling 896 Somatom CT systems due to sporadic software malfunctions that cause 3D reconstructions to hang during preview.

    Product
    Siemens Somatom CTs equipped with software syngo CT2010A, syngo CT2010B, syngo CT2011A and CT2012B. Computed tomography x-ray system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0936-2013·2013-03-20

    Bacterin Elutia Silicone Surgical Wound Drain Recalled for Cracks

    Bacterin International is recalling specific lots of Elutia silicone surgical wound drains because a portion of the drain was found to be cracked.

    Product
    Bacterin Elutia, Hubless Coated Silicone Surgical Wound Drain 24 Fr Round Hubless, Full-Fluted Coated with Silver Sulfadiazine STERILE, Box of 10 Part #7118. Indicated for use in surgical wound drainage.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0943-2013·2013-03-20

    Smith & Nephew Recalls Mislabelled Trigen Internal Hex Reconstruction Screws

    Smith & Nephew is recalling 69 Trigen internal hex reconstruction screws because 75 mm and 80 mm units were packaged in incorrect boxes and labels.

    Product
    INTERNAL HEX RECON SCREW, TI-6AL-4V, REF 7162380, TRIGEN (R) INTERNAL HEX CAPTURED RECON SCREW, QTY: (1), 6.4 MM, 80 MM, TITANIUM, Smith & Nephew, Inc. Orthopedic. Bone screw for intramedullary rod fixation.
    Category
    Medical Device
    Distribution
    11 states
  • ModerateFDA (Devices)·Z-0924-2013·2013-03-20

    Keystone Dental Recalls Mislabeled Genesis Straight Esthetic Abutments

    Keystone Dental Inc is recalling 22 units of Genesis Straight Esthetic abutments that were mislabeled with incorrect dimensions.

    Product
    Genesis Straight Esthetic 5.0 mm 3. mm Cuff Abutment Part Number: G71205 Genesis implant for single stage or two stage surgical procedures all types of of bone in partially or fully edentulous mandibles and maxillae.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0923-2013·2013-03-20

    Keystone Dental Recalls Mislabeled Genesis Straight Esthetic Abutments

    Keystone Dental Inc is recalling 35 units of Genesis Straight Esthetic abutments because they were mislabeled as 4.0 mm 1 mm cuff units when they are actually 5.0 mm 3 mm cuff units.

    Product
    Genesis Straight Esthetic 4.0 mm 1mm Cuff Abutment Part Number: G71200 Genesis implant for single stage or two stage surgical procedures all types of of bone in partially or fully edentulous mandibles and maxillae.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0929-2013·2013-03-20

    Abbott Recalls Mislabeled AMO Sensar Intraocular Lenses

    Abbott Medical Optics is recalling 155 AMO Sensar Intraocular Lenses because two production orders contained mislabeled units. The lenses are distributed worldwide.

    Product
    AMO Sensar Intraocular Lenses (IOLs), Model AR40e, Sensar Foldable IOL with OptiEdge Product Usage: These are ultraviolet-absorbing posterior chamber intraocular lenses for use after cataract extraction.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0927-2013·2013-03-20

    Innominata Lyme Disease Microplate EIA Kit Recalled for Low-Reactivity Issues

    Innominata dba GenBio is recalling 195 units of the Anti-Borrelia (Lyme) Microplate EIA Kit due to multiple incidents of low-reacting assay plates.

    Product
    ANTI-BORRELIA (LYME) MICROPLATE EIA Kit, Catalog # 32507 Kit Lot Number 120960. Package Insert Supplement: Calibrator-1206 U/mL, Positive Control-228 - 532 U/mL, and Negative Control-<120 U/mL; Manufactured by Innominata dba GenBio for Bio-Rad. The kit is used as an aid in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0933-2013·2013-03-20

    Siemens Total Iron Binding Capacity Reagent Cartridge Recall for Labeling Error

    Siemens is recalling Total Iron Binding Capacity reagent cartridges because the stated analytical sensitivity in the instructions is no longer valid.

    Product
    Siemens Total Iron Binding Capacity (IBCT) Flex Reagent Cartridge. An in vitro diagnostic test intended to quantitatively measure Total Iron Binding Capacity in human serum.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0892-2013·2013-03-13

    Ad-Tech Macro Micro Subdural Electrodes Recalled for Sharp Edges

    Ad-Tech Medical Instrument Corporation is recalling Macro Micro Subdural Electrodes because they may have sharp edges or fracture, posing a risk of injury to brain tissue.

    Product
    Ad-Tech Medical Instrument Corporation Macro Micro Subdural Electrode. For temporary (<30 days) use with recording, monitoring and stimulation equipment, for the recording, monitoring and stimulation of electrical signals on the surface level of the brain. The recording of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0907-2013·2013-03-13

    Siemens ARTISTE syngo RT Therapist software recall for beam delivery error

    Siemens is recalling 5 ARTISTE digital linear accelerators due to a software defect that may cause repeated delivery of radiation beams.

    Product
    SIEMENS brand ARTISTE syngo RT Therapist (RTT) version 4.3, ARTISTE Model, Part No. 08162815, Digital linear accelerators, MOSAIQ OIS system, Distributed by SIEMENS Healthcare IM CR RO, CR Radiation Oncology, Manufactured by SIEMENS AG, MEDICAL SOLUTIONS, GERMANY.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0901-2013·2013-03-13

    GE Healthcare Recalls Advantage Workstation Volume Viewer Software

    GE Healthcare is recalling Advantage Workstation Volume Viewer software due to potential safety issues that may result in incorrect views and measurements.

    Product
    GE Healthcare Volume Viewer Plus 5.x (Advantage Workstation 4.2) Volume Viewer 3.x (Advantage Workstation 4.1) Volume Analysis (Advantage Workstation 4.0) Volume Analysis (Advantage Workstation 3.1) Advantage Windows Volume Rendering Option is intended to provide fast…
    Category
    Medical Device
    Distribution
    27 states