The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

28501–28525 of 40397

  • HighFDA (Devices)·Z-0535-2017·2016-11-23

    ICU Medical Recalls Transpac Pressure Transducer Kits Due to Leak Risk

    ICU Medical is recalling 90 units of Transpac pressure transducer kits due to a potential leak in the SafeSet Reservoir.

    Product
    DOUBLE LINE KIT W/03ML FLUSH DEVICE & SAFESET, Item No. 46099-18 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure into electrical…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0509-2017·2016-11-23

    ICU Medical Recalls SafeSet Reservoir and Blood Sampling Kits

    ICU Medical is recalling 20 units of SafeSet Reservoir and blood sampling kits due to a potential leak hazard.

    Product
    OPEN HEART KIT W/03ML FLUSH DEVICE FOR CUMBERLAND COUNTY HOSP., Item No. 46094-08 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure into…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0534-2017·2016-11-23

    ICU Medical Recalls SafeSet Reservoir Kits Due to Potential Leak

    ICU Medical is recalling 140 units of SafeSet Reservoir and blood sampling kits containing Transpac IV transducers due to a potential for leak.

    Product
    Cath Lab Kit w/03 ml Squeeze Flush, Pressure Tubing, Guidewire, 10 cc Syringes and 3 Way Stopcock, Item No. 46098-87NS The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0498-2017·2016-11-23

    ICU Medical Recalls Transpac Transducer Kits Due to Leak Risk

    ICU Medical is recalling specific Transpac IV transducer kits because of a potential leak. The recall covers 1,440 units distributed nationwide.

    Product
    TRIFURCATED DISPOSABLE TRANSDUCER KIT W/03ML FLUSH DEVICE FOR JOHNS HOPKINS/BAYVIEW, Item No. 46088-74 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0443-2017·2016-11-23

    ICU Medical Recalls Transpac IV Monitoring Kits Due to Leak Risk

    ICU Medical is recalling specific Transpac IV monitoring kits because of a potential leak in the SafeSet Reservoir and blood sampling components.

    Product
    TRANSPAC¿ IV MONITORING KIT, 72", DISPOSABLE TRANSDUCER, 3 ML SQUEEZE FLUSH, MACRODRIP (POLE MOUNT), Item No. 42632-05 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0457-2017·2016-11-23

    ICU Medical Recalls Transpac IV Transducer Kits Due to Leak Risk

    ICU Medical is recalling 60 units of Transpac IV transducer kits due to a potential leak in the SafeSet Reservoir system.

    Product
    CATH LAB KIT FOR ALBERT EINSTEIN M.C., Item No. 46047-19 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure into electrical currents that…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0608-2017·2016-11-23

    Siemens Recalls CT Systems for Software Safety Bug Fixes

    Siemens is recalling seven CT systems to install a software update that fixes bugs and corrects potential safety issues.

    Product
    SOMATOM Definition Flash, Computed tomography x-ray system The Siemens SOMATOM Definition AS/ AS+ (Project P46) systems are intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial plane taken at…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0395-2017·2016-11-23

    Roche Tina-Quant Hemoglobin A1c Test Recalled for Erroneously High Results

    Roche Diagnostics is recalling Tina-Quant Hemoglobin A1c Gen. 2 tests because they may produce erroneously high results, potentially leading to incorrect diabetes treatment.

    Product
    Tina-Quant Hemoglobin A1c Gen. 2 Hemoglobin A1c test Catalog number 04528123190 / 05401640190
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0473-2017·2016-11-23

    ICU Medical Recalls Transpac Pressure Transducers Due to Leak Risk

    ICU Medical is recalling 75 units of Transpac pressure transducers and SafeSet reservoirs due to a potential leak hazard.

    Product
    M.K. WITH 03ML FLUSH DEVICE FOR DRISCOLL FOUNDATION CHILDRENS HOSP., Item No. 46068-02 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0545-2017·2016-11-23

    ICU Medical Recalls Transpac IV Monitoring Kits Due to Leak Risk

    ICU Medical is recalling 30 units of Transpac IV Trifurcated Monitoring Kits because of a potential leak in the SafeSet Reservoir and blood sampling components.

    Product
    TRANSPAC¿ IV TRIFURCATED MONITORING KIT 72", 3 DISPOSABLE TRANSDUCERS, 3 3 ML INTRAFLO¿ FLUSHES, MACRODRIP (POLE MOUNT), Item No. 46101-39 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0558-2017·2016-11-23

    ICU Medical Recalls Transpac IV Monitoring Kits Due to Leak Risk

    ICU Medical is recalling specific Transpac IV Monitoring Kits because of a potential leak in the SafeSet Reservoir and blood sampling components.

    Product
    Transpac¿ IV Monitoring Kit w/Safeset" Blood Sampling Port and 03 ml Squeeze Flush Device 10 cc Sheathed Syringe, Item No. 46109-74 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0438-2017·2016-11-23

    ICU Medical Recalls SafeSet Reservoir Kits Due to Potential Leak

    ICU Medical is recalling 200 SafeSet Reservoir and blood sampling kits containing Transpac IV transducers due to a potential for leak.

    Product
    Monitoring Kit w/TP4, 30 ml Squeeze Flush and Needleless Valve, Item No. 42598-01 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure into…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0452-2017·2016-11-23

    ICU Medical Recalls Transpac IV Monitoring Kits Due to Leak Risk

    ICU Medical is recalling 740 units of Transpac IV Bifurcated Monitoring Kits due to a potential leak in the SafeSet Reservoir and blood sampling components.

    Product
    TRANSPAC¿ IV BIFURCATED MONITORING KIT 72 INCH, 2 DISPOSABLE TRANSDUCERS, 2 3 ML SQUEEZE FLUSH, MACRODRIP (POLE MOUNT), Item No. 42652-05 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0532-2017·2016-11-23

    ICU Medical Recalls SafeSet Reservoir Kits Due to Potential Leak

    ICU Medical is recalling 380 units of SafeSet Reservoir and blood sampling kits containing Transpac IV transducers due to a potential for leak.

    Product
    4 PORT "OFF" MANIFOLD, w/HP STOPCOCK, WASTE BAG ASSY, 10 cc SYRINGE & AD SETS, Item No. 46098-78 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0592-2017·2016-11-23

    Alphatec Recalls Arsenal Spinal Fixation System Set Screws for Disengagement Risk

    Alphatec Spine is recalling Arsenal Spinal Fixation System Set Screws due to a trend of postoperative disengagement from the screw body.

    Product
    Arsenal Spinal Fixation System, Set Screw, Part No. 47127 Product Usage: Usage: The Arsenal Spinal Fixation System is intended for posterior, non-cervical, spinal fixation as an adjunct to fusion for the treatment of degenerative disease, deformity, and trauma indications.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0521-2017·2016-11-23

    ICU Medical Recalls SafeSet Reservoir Kits Due to Potential Leak

    ICU Medical is recalling 10 units of SafeSet Reservoir and blood sampling kits containing Transpac IV transducers due to a potential for leak.

    Product
    SAFESET" KIT W/03ML FLUSH DEVICE FOR HOLMES REG. M.C., Item No. 46097-30 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure into electrical…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0523-2017·2016-11-23

    ICU Medical Recalls Transpac IV Transducer Kits Due to Leak Risk

    ICU Medical is recalling 70 units of Transpac IV transducer kits due to a potential leak in the SafeSet Reservoir system.

    Product
    QUAD TRANSDUCER KIT WITH 03ML FLUSH DEVICE FOR LUBBOCK HEART HOSP., Item No. 46097-36 The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0607-2017·2016-11-23

    Siemens Recalls CT Systems for Software Safety Bug Fixes

    Siemens is releasing a software update for specific CT systems to correct potential safety issues and improve performance.

    Product
    SOMATOM Definition Edge, Computed tomography x-ray system The Siemens SOMATOM Definition AS/ AS+ (Project P46) systems are intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial plane taken at…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0405-2017·2016-11-23

    Bard Inlay Optima Ureteral Stent Recalled for Labeling Update

    C.R. Bard is recalling 75,089 Bard Inlay Optima ureteral stents to add a warning about potential knots during removal.

    Product
    Bard Inlay Optima¿ Multi-Length Ureteral Stent Coated Double Pigtail Ureteral Stent with Stent and Multi- Length Ureteral Stent with Suture, Manufacturer: C.R. Bard, Inc., Covington, GA 30014.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0412-2017·2016-11-23

    Sorin Orchestra Programmer Recalled for Inaccurate Longevity Estimates

    Sorin Group USA is voluntarily recalling 847 Orchestra and Orchestra Plus programmers because residual longevity estimates may be inaccurate.

    Product
    The ORCHESTRA Programmer A portable device, equipped with a microprocessor used to program and interrogate Sorin implantable pacemakers and defibrillators. The programmer also provides measurement, ECG display and report printing functions that are essential for monitoring…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0406-2017·2016-11-23

    C.R. Bard Recalls Totalis Endo Kits for Labeling Update

    C.R. Bard is recalling 75,089 Totalis endo kits to add a warning about potential knots during removal.

    Product
    Totalis, RIGID and Totalis"I Flex ENDO KIT, Manufacturer: C.R. Bard, Inc., Covington, GA 30014.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0403-2017·2016-11-23

    Bard Fluoro-4 Silicone Ureteral Stent Recall for Labeling Update

    C.R. Bard is recalling 75,089 units of Bard Fluoro-4 Silicone Ureteral Stents to add a warning about potential knots during removal.

    Product
    Bard Fluoro-4 Silicone Ureteral Stent, Bard¿ Fluoro-4", Silicone Ureteral Coil Stent; Bard¿ Silicone Uretera l Coil Stent with Figure Four, End, Manufacturer: C.R. Bard, Inc., Covington, GA 30014.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0408-2017·2016-11-23

    Beckman Coulter Recalls Access Ostase QC for Expiration Date Issues

    Beckman Coulter is recalling Access Ostase QC kits because they do not meet expiration date claims within 10% criteria.

    Product
    Access Ostase QC, Catalog No. 37309, B83877 Product Usage: The Access Ostase QC is intended for monitoring system performance of the Access Ostase assay.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0577-2017·2016-11-23

    Atrium Medical Recalls Trocar Catheters Due to Inaccurate Labeling

    Atrium Medical is recalling 10 Fr Trocar catheters because the packaging label displays more holes than the product actually contains.

    Product
    Atrium Medical 10 Fr Trocar catheter, Sterile Model Number: 8410 Intended to facilitate the evacuation of air and/or fluid from the chest cavity or mediastinum.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0601-2017·2016-11-23

    Siemens Artis Q Angiographic X-ray System Recalled for Footswitch Defect

    Siemens is recalling 4,657 Artis Q angiographic x-ray systems because the semi-automatic focus switch may not work as intended when the footswitch is pressed multiple times.

    Product
    Artis Q, Angiographic x-ray system Product Usage: The Artis systems are a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Procedures that…
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.