The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

28001–28025 of 40397

  • HighFDA (Devices)·Z-0941-2017·2017-01-11

    Interventional Spine Recalls G3 Opticage Expandable Interbody Fusion Devices

    Interventional Spine Inc is recalling 239 G3 Opticage Expandable Interbody Fusion Devices because the proximal end may separate during implantation, preventing the device from expanding.

    Product
    G3 Opticage Expandable Interbody Fusion Device, Model No. 9180-00, 9180-01, 9180-06, 9180-07, 9180-17, 9101-00, 9101-06 The Opticage Expandable Interbody Fusion Device is a posterior lumbar intervertebral body fusion device and is indicated for use with autogenous bone graft in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0939-2017·2017-01-11

    Merge Unity PACS Software Recalled for Incorrect Mammogram Image Association

    Merge Healthcare is recalling Unity PACS software version 11.0 because it may fail to associate the correct mammogram image when two images exist for the same view.

    Product
    DR Systems Unity PACS software, now known as Merge Unity PACS software.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-0947-2017·2017-01-11

    Aesculap Recalls Gomco Circumcision Clamps Due to Excessive Bleeding Reports

    Aesculap Implant Systems LLC is recalling 437 units of Gomco Circumcision Clamps nationwide after receiving complaints of excessive bleeding following use.

    Product
    Gomco Circumcision Clamps with separate O-Ring Component: The device is packaged non-sterile and has no shelf-life The Gomco clamp is intended to be used for circumcision surgeries
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0948-2017·2017-01-11

    Tepha GalaSHAPE 3D Medical Device Recalled for Endotoxin Specification Exceedance

    Tepha Incorporated is recalling 29 units of GalaSHAPE 3D medical devices because endotoxin levels slightly exceeded specifications.

    Product
    GalaSHAPE 3D; product code SH3D03, a medium size oval GalaSHAPE" 3D is indicated for use as a bioresorbable scaffold for soft tissue support and to repair, elevate and reinforce deficiencies where weakness or voids exist that require the addition of material to obtain the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0949-2017·2017-01-11

    Merit PreludeEASE Hydrophilic Sheath Introducer Dilator Recall

    Merit Medical Systems is recalling 335 PreludeEASE Hydrophilic Sheath Introducer Dilators because the tips are undersized and cannot pass a 0.021-inch guide wire.

    Product
    PreludeEASE Hydrophilic Sheath Introducer Dilator The Merit PreludeEASE Hydrophilic Sheath Introducer is intended to provide access and facilitate the percutaneous introduction of various devices into veins and/or arteries, including but not limited to the radial artery, while…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0242-2017·2017-01-11

    Gentell Hydrogel Ag Saturated Gauze Recalled for CGMP Deviations

    Gentell, Inc. is voluntarily recalling 3,000 units of Hydrogel Ag Saturated Gauze in three sizes due to Current Good Manufacturing Practice (CGMP) deviations.

    Product
    Gentell Hydrogel Ag Saturated Gauze, 2"x2"(NDC 61551-112-20), 4x4(NDC 61554-114-24) and 4"x8"(NDC 61554-118-28), Manufactured by: Gentell, 2701 Bartram Road, Bristol, PA 19007
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0943-2017·2017-01-11

    MicroPort Orthopedics Recalls Profemur R Rasp Handles Due to Machining Issues

    MicroPort Orthopedics is recalling 20 units of Profemur R Rasp Handles because machining issues may prevent them from properly mating with broaches.

    Product
    PROFEMUR(R) R RASP HANDLE, REF PPW38078, 1 EACH, NON-STERILE, MicroPort Orthopedics, Arlington, TN Instruments support the implantation of implants. Broach handles mate to the broach to allow for preparation of the femoral canal for the stem component to be implanted. This
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0940-2017·2017-01-11

    Infraredx Recalls TVC Imaging System Due to Image Appearance Issues

    Infraredx, Inc. is recalling seven TVC Imaging System units because near-infrared images sometimes displayed lipid core plaques with an unusual horizontal orientation.

    Product
    TVC Imaging System model TVC-MC9 , for the near-infrared examination of coronary arteries in patients undergoing invasive coronary angiography The TVC Imaging System is an intravascular imaging device that simultaneously assesses vessel composition and structure using…
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0919-2017·2017-01-04

    Siemens Recalls SOMATOM Scope CT Systems for Power Cutout Risk

    Siemens is recalling 13 SOMATOM Scope CT systems to replace a component that could cause a power cutout during use.

    Product
    SOMATOM Scope, Computed tomography x-ray system
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-0928-2017·2017-01-04

    Allen Medical Systems Recalls Arthex S3 Arm Sleeve Connectors

    Allen Medical Systems is recalling 420 Arthex S3 Arm Sleeve Connectors because they may separate unexpectedly during use, potentially causing moderate injury to patients.

    Product
    Arthex S3 Arm Sleeve Connector; Catalog Number AR-1650-02; manufactured and distributed between March and November 2016.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0916-2017·2017-01-04

    GE Healthcare Recalls X-Ray Systems Due to CRT Monitor Fall Risk

    GE Healthcare is recalling specific X-ray systems because aged CRT monitors may fall. The recall covers 1,598 units distributed in the US and internationally.

    Product
    SFX
    Category
    Medical Device
    Distribution
    41 states
  • HighFDA (Devices)·Z-0906-2017·2017-01-04

    GE Healthcare Recalls CRT Monitors Due to Potential Fall Hazard

    GE Healthcare is recalling specific CRT monitors due to the potential for the units to fall. The recall affects multiple system models including ADVANTX and Prestige.

    Product
    ADVANTX LCLP+
    Category
    Medical Device
    Distribution
    41 states
  • HighFDA (Devices)·Z-0901-2017·2017-01-04

    Medtronic NIM EMG Endotracheal Tubes Recalled for Exposed Wire Hazard

    Medtronic Xomed is recalling NIM EMG Endotracheal Tubes because wire in the tubing can become exposed, posing potential harm to intubated patients.

    Product
    NIM EMG Endotracheal Tube, 6.0 mm I.D. x 8.8 mm O.D. (27 FR), Reinforced, Sterile, Rx only. Individually packaged.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0918-2017·2017-01-04

    Shimadzu X-ray High Voltage Generator Recalled for Oil Leak Risk

    Shimadzu Medical Systems is recalling 13 X-ray high voltage generators due to a potential oil leak from the x-ray tube housing.

    Product
    Shimadzu X-ray High Voltage Generator Model No. UD150B-40 on SONIALVISION safire II/17 systems with 0.7/1.2JG326D X-Ray Tube Diagnostic x-ray high voltage generator.
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-0921-2017·2017-01-04

    Siemens Recalls CT Systems for Potential Power Cutout Defect

    Siemens is recalling 13 SOMATOM Perspective CT systems to replace a component that could cause power cutouts during use.

    Product
    SOMATOM Perspective, Computed tomography x-ray system
    Category
    Medical Device
    Distribution
    10 states

Looking for a different category? Browse all recalls.