The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

27226–27250 of 40397

  • ModerateFDA (Devices)·Z-1753-2017·2017-04-12

    Philips BrightView X Gamma Camera Recall Due to Brake Hub Assembly Error

    Philips Medical Systems is recalling 27 BrightView X gamma cameras because a brake hub assembly error can cause the detector to backdrive.

    Product
    BrightView X 3/8 model number 882478 BrightView and BrightView X are gamma cameras designed for single or dual detector nuclear imaging accommodating a broad range of Emission Computed Tomography (ECT) studies. The cameras can be used to perform planar static, dynamic, gated…
    Category
    Medical Device
    Distribution
    29 states
  • ModerateFDA (Devices)·Z-1737-2017·2017-04-12

    Agilent Bond Elut OMS Cards Recalled for Lack of FDA Clearance

    Agilent Technologies is recalling Bond Elut OMS cards because they were marketed without the required FDA 510(k) clearance.

    Product
    Bond Elut OMS (Dried Matrix Spotting)' Product; Catalog model numbers: 5022-8226 - Auto DBS Card (LCMS Extraction Sys) 50 pk; A400150 - Bond Elut EMS Card 50/Pk; A400150K - Bond Elut DMS Card BULK 500/pk; A400150SK - Bond Elut DMS Card Starter Kit A42001 - Bond Elut MDS…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1729-2017·2017-04-12

    Intuitive Surgical Recalls da Vinci Xi EndoWrist Stapler Release Kits

    Intuitive Surgical is recalling da Vinci Xi EndoWrist Stapler Release Kits because misinterpretation of instructions may result in tool damage.

    Product
    STAPLER,IS4000; da Vinci Xi EndoWrist Stapler Release Kit (SRK); model number 470298. da Vinci Xi Turkish SRK General and Plastic Surgery: The Intuitive Surgical EndoWrist Stapler 45, Stapler 45 Reloads and other Stapler Accessories are intended to be used with the da Vinci¿…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1718-2017·2017-04-12

    Intuitive Surgical Recalls da Vinci Xi EndoWrist Stapler Release Kits

    Intuitive Surgical is recalling da Vinci Xi EndoWrist Stapler Release Kits because misinterpretation of instructions may result in tool damage.

    Product
    STAPLER,IS4000; da Vinci Xi EndoWrist Stapler Release Kit (SRK); model number 470298. da Vinci Xi Finnish SRK General and Plastic Surgery: The Intuitive Surgical EndoWrist Stapler 45, Stapler 45 Reloads and other Stapler Accessories are intended to be used with the da…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1748-2017·2017-04-12

    Siemens ADVIA Centaur BR Assay Recalled for Potential Interference

    Siemens Healthcare Diagnostics is recalling ADVIA Centaur BR assays due to potential interference from the Syphilis assay on the same systems.

    Product
    Siemens ADVIA Centaur BR assay Cat No. 03896216, SMN 10334837 (5-pack/250 tests) BR Assay for CA 27.29 The ADVIA Centaur¿ BR assay is an in vitro diagnostic test for the quantitative serial determination of cancer antigen CA 27.29 in human serum using the ADVIA Centaur¿…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1704-2017·2017-04-12

    Beckman Coulter Recalls AU680 and AU5800 Rack ID Labels Due to Mismatch

    Beckman Coulter is recalling Rack ID Labels for AU680 and AU5800 analyzers because the displayed ID number and barcode do not match.

    Product
    Beckman Coulter Chemistry Analyzer AU680/AU5800, Catalog No. MU907400 (Rack ID Labels) The Beckman Coulter AU680 and the AU5800 Clinical Chemistry Analyzers are an automated chemistry analyzer that measures analytes in samples, in combination with appropriate reagents…
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1711-2017·2017-04-12

    Beckman Coulter Recalls UniCel DxC 600i SYNCHRON Access Clinical Systems

    Beckman Coulter is recalling specific UniCel DxC 600i SYNCHRON Access Clinical Systems because a circuit board defect can cause the device to stop running and cancel tests.

    Product
    UniCel DxC 600i SYNCHRON Access Clinical System, Part No. A25637, A25638 Product Usage: The Access 2 and UniCel DxI Access Immunoassay Systems are in vitro diagnostic devices used for the quantitative, semi-quantitative or qualitative determination of various analyte…
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1749-2017·2017-04-12

    Siemens ADVIA Centaur BR Assay Recalled for Potential Syphilis Assay Interference

    Siemens is recalling ADVIA Centaur BR assays due to potential interference from the Syphilis assay, which may affect test accuracy.

    Product
    Siemens ADVIA Centaur BR assay Cat No. 09010686, SMN 10340081 (5-pack/250 tests - REF) BR Assay for CA 27.29 The ADVIA Centaur¿ BR assay is an in vitro diagnostic test for the quantitative serial determination of cancer antigen CA 27.29 in human serum using the ADVIA…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1712-2017·2017-04-12

    Siemens ADVIA Chemistry Enzyme 2 Calibrator Recalled for Positive Bias

    Siemens is recalling ADVIA Chemistry Enzyme 2 Calibrators due to a positive bias of up to 41% in AST and AST_c assay results.

    Product
    ADVIA Chemistry Enzyme 2 Calibrator, multi-analyte mixture Product Usage: Assays included in Enzyme 2 Calibrator: AST, AST_c ALT, ALT_c, ALTP5P, ALTP_c, ASTP5P and ASTP_c
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1727-2017·2017-04-12

    Intuitive Surgical Recalls da Vinci Xi Stapler Release Kits Due to Instruction Card Issues

    Intuitive Surgical is recalling da Vinci Xi EndoWrist Stapler Release Kits because misinterpretation of instructions may result in tool damage.

    Product
    STAPLER,IS4000; da Vinci Xi EndoWrist Stapler Release Kit (SRK); model number 470298. da Vinci Xi Swedish SRK General and Plastic Surgery: The Intuitive Surgical EndoWrist Stapler 45, Stapler 45 Reloads and other Stapler Accessories are intended to be used with the da Vinci¿…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1720-2017·2017-04-12

    Intuitive Surgical Recalls da Vinci Xi Stapler Release Kits

    Intuitive Surgical is recalling da Vinci Xi Stapler Release Kits because misinterpretation of instructions may result in tool damage.

    Product
    STAPLER,IS4000; da Vinci Xi EndoWrist Stapler Release Kit (SRK); model number 470298. da Vinci Xi Norwegian SRK General and Plastic Surgery: The Intuitive Surgical EndoWrist Stapler 45, Stapler 45 Reloads and other Stapler Accessories are intended to be used with the da…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1725-2017·2017-04-12

    Intuitive Surgical Recalls da Vinci Xi EndoWrist Stapler Release Kits

    Intuitive Surgical is recalling da Vinci Xi EndoWrist Stapler Release Kits because misinterpretation of instructions may result in tool damage.

    Product
    STAPLER,IS4000; da Vinci Xi EndoWrist Stapler Release Kit (SRK); model number 470298. da Vinci Xi Korean SRK General and Plastic Surgery: The Intuitive Surgical EndoWrist Stapler 45, Stapler 45 Reloads and other Stapler Accessories are intended to be used with the da…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1417-2017·2017-04-05

    Philips HeartStart MRx Monitor/Defibrillator Recalled for Potential Failure to Deliver Therapy

    Philips is recalling HeartStart MRx Monitor/Defibrillators because they may fail to deliver therapy or monitoring when operating on a single battery.

    Product
    HeartStart MRx Monitor/Defibrillator, Model numbers: M3535A (M3535ATZ) M3536A (M3536ATZ), M3536M, M3536MC, M3536M2, M3536M4, M3536M5, M3536M6, M3536M7, M3536M8, M3536M9
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1575-2017·2017-04-05

    FDA Recalls 170 Sterile Laparoscopic Procedure Trays Due to Glove Splitting

    Resource Optimization & Innovation LLC is recalling 170 sterile laparoscopic procedure trays because a light glove component can split during application, breaking the sterile field.

    Product
    Regard, Item Number: 880341003, Sterile, GS0775C - Laparoscopic - OSU
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1668-2017·2017-04-05

    Resource Optimization Recalls Sterile Custom Procedure Trays Due to Glove Splitting

    Resource Optimization & Innovation LLC is recalling 24 sterile custom procedure trays because a light glove component can split during application, breaking the sterile field.

    Product
    Regard, Item Number: 800508003, Sterile, LD0586C - C Section - Jasper
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1497-2017·2017-04-05

    Merit Medical Recalls 7F Prelude Short Sheath Introducers Due to Detachment Risk

    Merit Medical Systems is voluntarily recalling 1,265 units of 7F Prelude Short Sheath Introducers because the sheath marker tips may detach during use.

    Product
    7F Prelude¿ Short Sheath Introducer. Catalog Numbers: K15-00070, K15-00170, PSS-7F-4-035MT, PSS-7F-4MT. Produc Usage: The Merit Prelude¿ Short Sheath Introducer is intended to provide access and facilitate the percutaneous introduction of various devices into veins and/or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1561-2017·2017-04-05

    FDA Recalls Sterile Custom Procedure Trays Due to Glove Splitting Risk

    Resource Optimization & Innovation LLC is recalling 42 sterile custom procedure trays because a light glove component can split, potentially breaking the sterile field.

    Product
    Regard, Item Number: 880323003, Sterile, LD0754C - C Section - OSU
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1646-2017·2017-04-05

    FDA Recalls Sterile Custom Procedure Trays Due to Glove Splitting Hazard

    Resource Optimization & Innovation LLC is recalling 274 sterile custom procedure trays because a light glove component can split, breaking the sterile field.

    Product
    Regard, Item Number: 800410004, Sterile, CV0479D- Open Heart PK - Spohn
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1580-2017·2017-04-05

    Recall of Regard Open Heart Procedure Kits Due to Glove Splitting

    Resource Optimization & Innovation LLC is recalling 117 sterile open heart procedure kits because a light glove component can split, breaking the sterile field.

    Product
    Regard, Item Number: 800410003, Sterile, CV0479C - Open Heart PK - Spohn
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1613-2017·2017-04-05

    FDA Recalls 216 Custom Procedure Trays Due to Glove Splitting Hazard

    Resource Optimization & Innovation LLC is recalling 216 custom procedure trays because a light glove component can split, breaking the sterile field.

    Product
    Regard, Item Number: 800553001, Sterile, OR0642A - Total Knee - Medical Center Santa Rosa
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1699-2017·2017-04-05

    Stryker Visum LED Surgical Lighting System Recalled for Mounting Defect

    Stryker is recalling 292 Visum LED Surgical Lighting systems because missing screws and user overloading may cause the equipment to fall.

    Product
    The Stryker Visum¿ LED Surgical Lighting system is intended to illuminate the operative site during surgical procedures with high intensity light. Affected part numbers are 0682001432 (EDS LIGHT SUSPENSION, CENTRAL AXIS, 9P/FP), 0682001286 (EDS LIGHT SUSPENSION, CENTRAL AXIS…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1578-2017·2017-04-05

    Recall of Regard Sterile Laparotomy Procedure Trays Due to Glove Defect

    Resource Optimization & Innovation LLC is recalling 30 sterile laparotomy procedure trays because a light glove component can split, breaking the sterile field.

    Product
    Regard, Item Number: 880342004, Sterile, GS0776D - Laparotomy - OSU
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1639-2017·2017-04-05

    Recall of Regard Sterile Lap PK Spohn Custom Procedure Trays

    Resource Optimization & Innovation LLC is recalling 3,000 sterile custom procedure trays because a light glove component can split, breaking the sterile field.

    Product
    Regard, Item Number: 800401002, Sterile, GS0470B - Lap PK - Spohn
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1656-2017·2017-04-05

    Recall of Robotic Hysterectomy Kits Due to Light Glove Splitting

    Resource Optimization & Innovation LLC is recalling 249 sterile robotic hysterectomy kits because a light glove component can split, breaking the sterile field.

    Product
    Regard, Item Number: 800416002, Sterile, GY0485B - Robotic Hysterectomy Pk - Spohn
    Category
    Medical Device
    Distribution
    2 states

Looking for a different category? Browse all recalls.