The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

14001–14025 of 27263

  • HighFDA (Devices)·Z-0335-2024·2023-11-29

    Hysteroscope Model HYF-1T recalled due to moisture in device channels

    Aizu Olympus is recalling Hysteroscope Model HYF-1T devices because the channel air drying process after repair was not validated. Some returned units had residual moisture that could allow contamination and infection.

    Product
    Hysteroscope-For endoscopic diagnosis within the uterus Model Number: HYF-1T.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0366-2024·2023-11-29

    Manual resuscitators recalled due to carbon dioxide rebreathing defect

    SunMed Holdings recalls Ventlab STAT-Check manual resuscitators due to a backwards leak in the integrated manometer allowing CO2 rebreathing, which may impair ventilation. Multiple models (Adult, Infant, Pediatric) are affected and distributed nationwide.

    Product
    Ventlab, LLC STAT-Check manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. STAT-Check Adult Resuscitator REF #: SC9101B; 2. STAT-Check Infant Resuscitator RES #s: SC7101B & SC7101B-M0; 3. STAT-Check Pediatric Resuscitator R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0378-2024·2023-11-29

    Biomet Compress Device Anchor Plugs recalled for metal burrs in transverse holes

    Biomet is recalling Compress Device Short Anchor Plugs due to potential metal burrs in the transverse holes that may prevent proper placement of drill pins during surgery, potentially extending surgical time.

    Product
    Compress Device Short Anchor Plug, 10 MM-Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178552
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0381-2024·2023-11-29

    Biomet Compress Device Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs due to metal burrs that may prevent proper surgical installation and extend operation time. Distribution includes US nationwide and eight other countries.

    Product
    Compress Device Short Anchor Plug, 16 MM- Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178558
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0388-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug recalled due to metal burrs

    Biomet is recalling Compress Device Short Anchor Plugs (28 MM, Item 178570) due to potential metal burrs in transverse holes that may prevent surgical instruments from passing through, extending surgery duration.

    Product
    Compress Device Short Anchor Plug, 28 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178570
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0324-2024·2023-11-29

    Solea Laser Surgical Instrument Models 2.0 and 3.0 Recall for Unintended Activation

    Convergent Dental is recalling 39 Solea laser surgical instruments due to potential unintended laser activation without foot pedal depression. No injuries have been reported.

    Product
    Solea Models 2.0 and 3.0 Laser Surgical Instrument, Foot Pedal assembly SUB-00434 with foot pedal CUS-00226 Rev. K reworked
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0351-2024·2023-11-29

    BD Extension Sets Mislabeled as DEHP-Free Despite Containing Phthalates

    Certain BD Extension Sets sold as free of DEHP (di(2-ethylhexyl) phthalate) actually contain this restricted phthalate. The products have been distributed worldwide.

    Product
    BD Extension Sets (Product Name, Catalog #) BD SmartSite Filter Extension Set PE lined Standard bore 1 SmartSite bonded 0.2um Large PES Filter 1 PC RLL. L: 16 in PV: 4mL, Catalog # 10013902 BD EXTENSION SET TRI-PORT SMALLBORE TUBING CHECK VALVE 3 SmartSite" VALVES, Catalog
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0396-2024·2023-11-29

    Boston Scientific EXALT Model D Duodenoscope Recall: Fluid Ingress in Lens

    Boston Scientific is recalling certain EXALT Model D Single-Use Duodenoscopes worldwide due to fluid ingress in the lens, which causes poor image quality. Affected devices should not be used; contact the manufacturer.

    Product
    EXALT Model D Single-Use Duodenoscope: Outer box UPN# M00542420 & Outer box UPN# M0054242CE0.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0109-2024·2023-11-29

    Hand Sanitizer Recalled for Acetal and Acetaldehyde Contamination

    Integrity Biochem HSC 70-LM hand sanitizer in 55-gallon drums (Lot #2133607, manufactured 11/23/2021) is being recalled due to acetal and acetaldehyde contamination above FDA standards. Product was distributed to an Oklahoma distributor.

    Product
    Integrity Biochem HSC 70-LM, Alcohol Antiseptic 70%, Hand Sanitizer, Lemon Scented Topical Gel, 208.19 L (55 gallons) drum, Integrity Biochem, 1100 North Cresson Hwy, Cresson, TX 76035. Made in the USA NDC: 77512-044-03
    Category
    Drug
    Distribution
    1 state
  • HighFDA (Devices)·Z-0340-2024·2023-11-29

    Mobile Airway Scope Recalled Due to Unvalidated Drying Process

    Aizu Olympus has recalled 33 Mobile Airway Scope units due to an unvalidated air drying process. Some repaired units had wet channels, creating a potential risk of contamination and infection.

    Product
    Mobile airway scope-diagnosis and observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Numbers: MAF-DM2, MAF-GM, MAF-GM2, MAF-TM, MAF-TM2.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0395-2024·2023-11-29

    Philips MRI Gradient Coil Recall Due to Fire and Smoke Risk

    Philips is recalling SmartPath to dStream 1.5T MRI systems due to a potential gradient coil failure that could produce smoke or fire. The recall affects 119 units distributed nationwide and internationally.

    Product
    SmartPath to dStream for 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0110-2024·2023-11-29

    Hand Sanitizer Recalled for Chemical Contamination Above Specifications

    Integrity Biochem 70% alcohol hand sanitizer recalled due to acetal and acetaldehyde contamination above USP limits. The 55-gallon drums distributed in Oklahoma may not meet safety standards.

    Product
    Integrity Biochem HSC70-LV, Alcohol Antiseptic 70%, Hand Sanitizer, Lavender Scented Topical Gel 208.19L (55 gallons) drum, Integrity Biochem, 1100 North Cresson Hwy, Cresson, TX 76035. Made in the USA, NDC: 77512-047-03
    Category
    Drug
    Distribution
    1 state
  • HighFDA (Devices)·Z-0325-2024·2023-11-29

    IRON assay kits recalled for inaccurate diagnostic results

    Sentinel CH SpA is recalling IRON assay kits (Reference Numbers 6K95-41 and 6K95-30) that may produce falsely elevated results. Affected lots could cause inaccurate iron measurements and delays in patient test reporting.

    Product
    IRON assay, Reference Numbers 6K95-41 and 6K95-30
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0352-2024·2023-11-29

    Roche Tina-quant D-Dimer Test System Recalled for Inaccurate Results

    Roche is recalling Tina-quant D-Dimer Test System kits because they produce elevated results when used with lithium-heparin plasma samples, potentially affecting diagnostic accuracy.

    Product
    Tina-quant D-Dimer Test System, Fibrinogen/Fibrin Degradation Products Assay, Material Numbers 03001245322 - (cobas c 311, 501 and 502; INTEGRA 400 plus), 08105618190 - (cobas c 303 and 503)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0386-2024·2023-11-29

    Surgical implant anchor plugs may contain metal burrs affecting insertion

    Biomet's Compress Device Short Anchor Plugs may contain metal burrs in the transverse holes, which can prevent proper insertion of surgical tools and extend surgery time. The affected devices are distributed nationwide and internationally.

    Product
    Compress Device Short Anchor Plug, 24 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178566
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0326-2024·2023-11-29

    Alinity c Iron Reagent Recalled for Falsely Elevated Test Results

    The FDA is recalling Alinity c Iron Reagent lots due to inaccurate results. The reagent produces falsely elevated patient iron values and may prevent proper quality control verification.

    Product
    Alinity c Iron Reagent, Reference Number 08P3920
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0465-2024·2023-11-29

    Jeni's Splendid Ice Cream Recalled for Aluminum and Steel Contamination

    Jeni's Splendid Ice Cream Buttercream Birthday Cake is recalled for potential aluminum and stainless steel pieces in the product. Consumers should stop consuming and return all affected packages.

    Product
    Jeni's Splendid Ice Cream: Buttercream Birthday Cake Ice Cream packaged in paperboard pint cups with heat seals and paper lids - 8 pints per case
    Category
    Food
    Distribution
    0 states
  • HighFDA (Devices)·Z-0338-2024·2023-11-29

    Tracheal Fiberscope Airway Management Devices Recalled for Inadequate Channel Drying

    Aizu Olympus is recalling 65 tracheal fiberscope units worldwide due to an unvalidated air drying process. Moisture remaining in device channels after repair could allow contamination and pose an infection risk.

    Product
    Tracheal fiberscope-airway management, which includes observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Numbers: LF-DP, LF-GP, LF-TP.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0333-2024·2023-11-29

    Gastroscope Devices Recalled for Inadequate Channel Drying Process

    Aizu Olympus recalls 680 gastroscope-EUS devices due to unvalidated channel drying. Water remaining in the channels poses contamination and infection risks.

    Product
    Gastroscope-endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) and for endoscopic surgery within the upper digestive tract. Model Numbers: GF-UC140P-AL5, GF-UCT180, GF-UE160-AL5.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0397-2024·2023-11-29

    EXALT Model D Single-Use Duodenoscope Recalled for Lens Fluid Ingress

    Boston Scientific is recalling EXALT Model D Single-Use Duodenoscopes due to fluid ingress in the lens, which causes poor image quality during procedures.

    Product
    EXALT Model D Single-Use Duodenoscope, 2 pack: Outer box UPN# M00542421, Inner box UPN # M00542420 & Outer box UPN# M0054242CE1, Inner box UPN # M0054242CE0.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0328-2024·2023-11-29

    Ultrasonic Bronchoscopes Recalled Due to Inadequate Drying Validation

    Aizu Olympus is recalling 823 ultrasonic bronchoscopes (models BF-UC180F, BF-UC190F) because the channel air drying process was not validated, and some repaired units retained water that could cause contamination and infection.

    Product
    Bronchoscope - Ultrasonic: endoscopic real-time ultrasonic imaging, ultrasound guided needle aspiration and other endoscopic procedures within the airways, trancheobronchial tree, esophagus and surrounding organs Model Numbers: BF-UC180F, BF-UC190F.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0322-2024·2023-11-29

    Medtronic Mo.Ma Ultra Cerebral Protection Device manifold stickers mislabeled

    Medtronic has recalled the Mo.Ma Ultra Proximal Cerebral Protection Device due to mislabeled manifold stickers. Both sides of affected units were labeled identically, potentially causing confusion about which ports control the proximal versus distal balloons.

    Product
    Medtronic Mo.Ma Ultra Proximal Cerebral Protection Device, Model Number MOM0130068X5
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0332-2024·2023-11-29

    Rhinolaryngoscope Models Recalled for Unvalidated Air Drying Process

    Aizu Olympus rhinolaryngoscopes (models ENF-T3, ENF-VT2, ENF-VT3) are recalled. The air-drying process for the instrument channel was not validated, and water remaining in some devices after repair poses contamination and infection risk.

    Product
    Rhinolaryngoscope-for endoscopic diagnosis and treatment within the nasal lumens and airway anatomy (including nasopharyngeal and trachea). Model Numbers: ENF-T3, ENF-VT2, ENF-VT3.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0334-2024·2023-11-29

    Gastrointestinal videoscopes recalled due to unvalidated channel drying process

    Aizu Olympus is recalling 3,627 gastrointestinal videoscopes because the channel air drying process was not validated. A small percentage of devices returned after repair had wet channels, creating potential for contamination and risk of infection.

    Product
    Gastrointestinal videoscope-indicated for use within the upper digestive tract (including the esophagus, stomach, and duodenum). Model Numbers: GIF-1TH190, GIF-1TQ160, GIF-2T160, GIF-2TH180, GIF-H170, GIF-H180, GIF-H180J, GIF-H190, GIF-HQ190, GIF-LV1, GIF-N180, GIF-Q150, GIF-Q16
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0367-2024·2023-11-29

    V-Care manual resuscitators recalled for CO2 rebreathing defect

    SunMed's Ventlab V-Care manual resuscitators are being recalled due to a backwards leak in the integrated manometer that allows CO2 rebreathing. Affected devices were distributed nationwide.

    Product
    Ventlab, LLC V-Care manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. V-Care Child Resuscitator REF #s: VN4100MB, VN4100MCFB-3, VN4100MCP; 2. V-Care Infant Resuscitator REF #s: VN3100OB, VN3100MB-2, VN3100MB-M01, VNW3100MB-2, V
    Category
    Medical Device
    Distribution