The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

38526–38550 of 88304

  • ModerateFDA (Food)·F-2148-2019·2019-09-18

    Chicken of the Sea Salmon Pouches Recalled for Microbial Spoilage

    Tri-Union Frozen Products is recalling specific Chicken of the Sea salmon pouches due to microbial activity causing bloating. The product was distributed in four states.

    Product
    Lemon Chive Chicken of the Sea Wild-Caught Pink Salmon Skinless and Boneless, 2.5 oz (70 g) pouch: Shelf Stable UPC 0 48000 01179 4 and 0 480000 11817 7 individual pouch; UPC 1 00 48000 01179 1 - Case Chicken of the Sea International El Segundo, CA Product of…
    Category
    Food
    Distribution
    4 states
  • ModerateFDA (Food)·F-2153-2019·2019-09-18

    Abbott Recalls Similac Pro-Sensitive Bottles Due to Packaging Error

    Abbott Nutrition is recalling specific cartons of Similac Pro-Sensitive that may contain Similac Pro-Advance bottles due to a packaging error.

    Product
    Similac Pro-Sensitive, 2 fl. oz. plastic bottles packed 12 per carton.
    Category
    Food
    Distribution
    8 states
  • ModerateFDA (Food)·F-2147-2019·2019-09-18

    Cracked Pepper Chicken of the Sea Salmon Recalled for Bloating

    Tri-Union Frozen Products is recalling Cracked Pepper Chicken of the Sea Wild-Caught Pink Salmon pouches due to microbial spoilage causing bloating.

    Product
    Cracked Pepper Chicken of the Sea Wild-Caught Pink Salmon Skinless and Boneless, 2.5 oz (70 g) pouch: Shelf Stable UPC 0 48000 01179 4 and 0 480000 11817 7 individual pouch; UPC 1 00 48000 01179 1 - Case Chicken of the Sea International El Segundo, CA Product of…
    Category
    Food
    Distribution
    4 states
  • ModerateFDA (Food)·F-2144-2019·2019-09-18

    Calcium Supplement Recalled for Lacking Declared Vitamin D Content

    Jivan Shakti Inc. is recalling 790 bottles of Dr. Naram's Rasayana D Tablet because FDA testing found no Vitamin D in the product.

    Product
    Plastic Bottles labeled with: "Ancient Youth Secret - Since 500 B.C., DR. NARAM'S RASAYANA D TABLET, Calcium Supplement with Vitamin D*, Dietary Supplement, 60 Tablets, FOR EXPORT ONLY, Imported & Distributed by: Jivan Shakti INC, 933 South Street, Peekskill, NY 10566…
    Category
    Food
    Distribution
    20 states
  • ModerateFDA (Food)·F-2152-2019·2019-09-18

    Stonyfield Kids Strawberry Beet Berry Tubes Recalled for Misbranding

    Stonyfield Farm is recalling 4,064 cartons of Kids Strawberry Beet Berry Tubes because the outer carton labeling does not match the product.

    Product
    Stonyfield Kids Strawberry Beet Berry Tubes, 8 count-2oz each; 453g/package; Keep Refrigerated
    Category
    Food
    Distribution
    6 states
  • LowFDA (Drugs)·D-1848-2019·2019-09-18

    Mylan Recalls Gatifloxacin Ophthalmic Solution Due to Unknown Impurity

    Mylan Pharmaceuticals is recalling Gatifloxacin Ophthalmic Solution 0.5% due to an out-of-specification result for an unknown impurity.

    Product
    Gatifloxacin Ophthalmic Solution 0.5%, 2.5 mL per bottle, Rx Only, Mfd. for: Mylan Pharmaceuticals Inc., Morgantown, WV 26505. Made in India. NDC: 0378-5431-35
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2490-2019·2019-09-18

    Randox Calibration Serum Recalled for Incorrect Analyte Targets

    Randox Laboratories is recalling calibration sera due to realigned targets for AST and ALT. The recall affects 307 kits distributed nationwide and in several foreign locations.

    Product
    This is an in vitro diagnostic product intended for use as a calibration serum in clinical chemistry assays. Randox calibration sera contain 42 analytes and are based on lyophilized human serum. The concentrations and activities are suitable for calibration of clinical chemistry…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2492-2019·2019-09-18

    Medtronic Micra Pacemaker Documentation Update for Tether Removal

    Medtronic is updating the Micra Pacemaker Instructions for Use and Implant Procedure Tip Card to include specific information on tether removal during implant.

    Product
    Medtronic Micra MC1VR01, Single chamber transcatheter pacing system, REF MC1VR01US (US only). Cardiac pacemaker.
    Category
    Medical Device
    Distribution
    0 states
  • LowFDA (Drugs)·D-1847-2019·2019-09-18

    Lamivudine Tablets Recalled for Incorrect Package Insert Labeling

    American Health Packaging is recalling Lamivudine Tablets due to an error in the package insert that incorrectly lists tablet description coding.

    Product
    Lamivudine Tablets, USP, 150 mg, 30 (3x10) count Unit Dose Blisters Carton, NDC 60687-362-21 (Individual Dose NDC: 60687-362-11), Distributed by American Health Packaging, Columbus, OH
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2493-2019·2019-09-18

    Medtronic Micra Pacemaker Documentation Update for Tether Removal

    Medtronic is updating the Micra Pacemaker Instructions for Use and Implant Procedure Tip Card to clarify tether removal during implant.

    Product
    Medtronic Micra MC1VR01, REF MC1VR01 (OUS only). Cardiac pacemaker.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2481-2019·2019-09-11

    OMNIlife ApeX Acetabular Liner Recalled for Oxidation Test Failure

    OMNIlife science Inc. is recalling six ApeX acetabular liners that failed oxidation testing. The defect may cause higher wear rates, potentially leading to revision surgery.

    Product
    OMNIlife science, Inc. ApeX acetabular liner hip prosthesis component ApeX-LNK crosslinked Acetabular Insert, 10 deg hood; Product Code : H5-54840
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-2098-2019·2019-09-11

    Mountain Mel's Herbal Tea Recalled for Potential Salmonella Contamination

    Mountain Mel's Essential Goods LLC is recalling The Milk Lady's Herbal Tea due to potential Salmonella contamination. The product was distributed in California, Oregon, and Washington.

    Product
    The Milk Lady's Herbal Tea, packaged loose leaf in aluminum tin, net weight 2 oz or 56.5 grams. UPC: 7 99632 05658 4. The label is read in parts: "***The Milk Lady s FOR GREATER MILK FLOW & CALM NERVES***CAFFEINE-FREE HERBAL TEA*** Mountain Mel s Essential Goods, LLC…
    Category
    Food
    Distribution
    3 states
  • SevereFDA (Food)·F-2096-2019·2019-09-11

    Mountain Mel's Diges-Teas Herbal Tea Recalled for Salmonella Contamination

    Mountain Mel's Essential Goods LLC is recalling Diges-Teas Herbal Tea due to potential Salmonella contamination. The product was distributed in California, Oregon, and Washington.

    Product
    Diges-Teas Herbal Tea, packaged loose leaf in aluminum tin, net weight 2 oz or 56.5 grams. UPC: 7 99632 05665 2. The label is read in parts: "***Diges-Teas ***CAFFEINE-FREE HERBAL TEA*** Mountain Mels Essential Goods, LLC Welches, OR 97067***Supplement Facts***Fennel***…
    Category
    Food
    Distribution
    3 states
  • SevereFDA (Devices)·Z-2446-2019·2019-09-11

    Stryker Recalls Berchtold Chromophare Monitor Carrier Arms Due to Weld Defects

    Stryker Communications is recalling 52 Berchtold Chromophare Dual Monitor Carrier Arms or Dual Flat Panels because the mounts may have insufficient welds.

    Product
    Berchtold Chromophare Dual Monitor Carrier Arm or Dual Flat Panel, a component of Berchtold Chromophare Ceiling Mounted Surgical Light System.
    Category
    Medical Device
    Distribution
    21 states
  • SevereFDA (Food)·F-2097-2019·2019-09-11

    Mountain Mel's Peaceful Baby Herbal Tea Recalled for Salmonella Risk

    Mountain Mel's Essential Goods LLC is recalling Peaceful Baby For Colic & Teething Discomfort Herbal Tea due to potential Salmonella contamination.

    Product
    Peaceful Baby For Colic & Teething Discomfort Herbal Tea, packaged loose leaf in aluminum tin, net weight 2 oz or 56.5 grams. UPC: 7 99632 05656 0 The label is read in parts: "***Peaceful Baby FOR COLIC & TEETHING DISCOMFORT ***CAFFEINE-FREE HERBAL TEA*** Mountain Mels…
    Category
    Food
    Distribution
    3 states
  • HighFDA (Devices)·Z-2470-2019·2019-09-11

    B. Braun Epidural Tray Recall Due to Filter Membrane Damage

    B. Braun Medical is recalling 960 epidural trays because filter membrane damage prevents the filter from achieving its intended capacity.

    Product
    CE17TKFCN EPID TRAY W/ 17GA TUOHY NRFIT Catalog # 339186
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-2479-2019·2019-09-11

    OMNIlife ApeX Acetabular Liner Recalled for Oxidation Testing Failure

    OMNIlife science Inc. is recalling 14 ApeX acetabular liners that failed oxidation testing. The defect may cause higher wear rates, potentially leading to revision surgery.

    Product
    OMNIlife science, Inc. ApeX acetabular liner hip prosthesis component Serf Dual Mobility Cup Liner 53-28; Product code: H6-25328
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2474-2019·2019-09-11

    B. Braun Medical Recalls Cont. Epidural Needles Due to Filter Damage

    B. Braun Medical is recalling 1,230 units of CE18TKSTN Cont. Epidural Needles because the filter membrane is damaged, preventing the device from achieving its intended filter capacity.

    Product
    CE18TKSTN CONT EPID W/SOFT TIP NRFIT Catalog # 339191
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-2356-2019·2019-09-11

    Norm-O-Temp 111W Medical Device Recalled for Missing Tissue Damage Warning

    Cincinnati Sub-Zero Products LLC is recalling Norm-O-Temp model 111W units because the manual lacks instructions warning that exceeding 40 Celsius for extended periods can cause tissue damage.

    Product
    Norm-O-Temp model 111W
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Food)·F-2101-2019·2019-09-11

    Schrock's Sugar 'N Spice Recalls Maple Iced Cinnamon Rolls for Undeclared Walnuts

    Schrock's Sugar 'N Spice LLC is recalling Maple Iced Cinnamon Rolls because they contain undeclared walnuts. The product was sold in one store in West Virginia and one in Ohio.

    Product
    Maple Iced Cinnamon Rolls, Net Wt. 1.33 lbs., Walnuts on top in see-through clamshells with clear plastic lids. 8 rolls per clamshell.
    Category
    Food
    Distribution
    2 states
  • HighFDA (Devices)·Z-2480-2019·2019-09-11

    OMNIlife ApeX Acetabular Liner Recalled for Oxidation Test Failure

    OMNIlife science Inc. is recalling 22 ApeX acetabular liners that failed oxidation testing. The defect may cause higher wear rates, potentially leading to revision surgery.

    Product
    OMNIlife science, Inc. ApeX acetabular liner hip prosthesis component Serf Dual Mobility Cup Insert Liner 51-28; Product code: H6-25128
    Category
    Medical Device
    Distribution
    Distributed nationwide