The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

32976–33000 of 88304

  • ModerateFDA (Drugs)·D-1411-2020·2020-08-05

    Hand Sanitizer Recalled for Subpotent Alcohol and High pH Levels

    World Event Promotions, LLC is recalling Handese Advanced Instant Hand Sanitizer because the product was found to be subpotent and has high pH levels.

    Product
    Handese Advanced Instant Hand Sanitizer (Ethyl Alcohol 70%), 12 FL OZ (354 mL) bottles, www.handeseclean.com UPC 612520481094
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1445-2020·2020-08-05

    Sun Pharmaceutical Recalls Clonazepam Tablets Due to Cross-Contamination

    Sun Pharmaceutical is recalling Clonazepam Orally Disintegrating Tablets because routine stability testing detected cross-contamination with clozapine.

    Product
    Clonazepam Orally Disintegrating Tablets, USP, 0.125 mg, 60-count bottle, Rx only, Mfg by: Sun Pharmaceutical Industries, Inc. Cranbury, NJ 08512, NDC 57664-783-86
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1421-2020·2020-08-05

    MasterPharm Recalls Estriol 8 mg Capsules Due to Processing Control Deficiencies

    MasterPharm LLC is recalling Estriol 8 mg capsules nationwide due to a lack of processing controls that ensures conformity to specifications.

    Product
    Estriol 8 mg Capsule, 90 capsules per bottle, MasterPharm, 115-02 Liberty Ave, Richmond Hill, NY 11419, (866) 630-5600
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2702-2020·2020-08-05

    Smith & Nephew T-F1X0 RCG Drill Pac Recalled for Missing Sleeve

    Smith & Nephew is recalling T-F1X0 RCG Drill Pacs because some sterile packages contain only one sleeve instead of two, preventing the device from performing as intended for the second bone tunnel.

    Product
    Smith & Nephew T-F1X0 RCG Drill Pac, 2 mm Drill & (2) Sleeves - Product Usage: indicated for use in surgical arthroscopic rotator cuff repair procedures. REF/ Catalog Number : 014771
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1422-2020·2020-08-05

    MasterPharm Recalls Finasteride Plus Capsules Due to Processing Control Deficiencies

    MasterPharm LLC is recalling Finasteride Plus 1.25mg capsules nationwide because the product lacked processing controls to ensure it met specifications.

    Product
    Finasteride Plus 1.25mg Capsule, 90 capsules per bottle, MasterPharm, 115-02 Liberty Ave, Richmond Hill, NY 11419, (866) 630-5600
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1433-2020·2020-08-05

    MasterPharm Recalls Progesterone Capsules Due to Processing Control Deficiencies

    MasterPharm LLC is recalling 600 capsules of Progesterone Modified Release 100 mg due to a lack of processing controls that ensures conformity to specifications.

    Product
    Progesterone Modified Release 100 mg Capsule, 90 capsules per bottle, MasterPharm, 115-02 Liberty Ave, Richmond Hill, NY 11419, (866) 630-5600
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2698-2020·2020-08-05

    Synthes Recalls MatrixNEURO Screws Due to Incorrect Body Clip Labeling

    Synthes, Inc. is recalling 104 units of MatrixNEURO 5mm screws because the body clip is etched with '4', incorrectly indicating a 4mm screw, despite correct outer packaging.

    Product
    MatrixNEURO Screws - Product Usage: The intended use for this device is in fixation of cranial bones and facial skeleton in procedures such as craniotomies, reconstructive procedures, fracture repair, osteotomies, and selective orthognathic surgery of the maxilla and chin.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Drugs)·D-1441-2020·2020-08-05

    MasterPharm Recalls Testosterone/Anastrozole Pellets Due to Processing Control Deficiencies

    MasterPharm LLC is recalling Testosterone/Anastrozole Pellets 100/6 mg due to a lack of processing controls that ensures conformity to specifications.

    Product
    Testosterone/Anastrozole Pellet 100/6 mg, 100 pellets per bottle, MasterPharm, 115-02 Liberty Ave, Richmond Hill, NY 11419 (866) 630-5600
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2706-2020·2020-08-05

    Richard Wolf Recalls Tube Set for Transanal Endoscopic Microsurgery

    Richard Wolf GmbH is recalling 338 Tube Sets for TEM because smaller diameter tube material was used. The affected units were distributed internationally.

    Product
    Tube Set for TEM - Product Usage: Transanal Endoscopic Microsurgery (TEM) combination system and the instrument set for the TEM procedure are designed to provide access to the rectal cavity and accessible part of the lower sigmoid colon using a stereo and/or monocular endoscope…
    Category
    Medical Device
    Distribution
    0 states
  • LowFDA (Drugs)·D-1410-2020·2020-08-05

    Allergan Recalls Skin Medica Acne System Kits for Subpotency

    Allergan is recalling 8,555 Skin Medica Acne System kits nationwide because the products failed potency tests at 12 and 24 months.

    Product
    Skin Medica Acne System, Contains: Purifying Foaming Wash (Salicylic Acid 2.0%), 5 fl oz.; Purifying Toner (Salicylic Acid 2.0%), 6 fl oz,; Acne Treatment Lotion (Benzoyl Peroxide 2.5%), 2 fl oz., Distributed in the U.S.A. by Allergan, Irvine, CA 92612, UPC 300234966005
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1408-2020·2020-07-29

    Mystic Shield Hand Sanitizer Recalled for Undeclared Methanol

    Transliquid Technologies is recalling Mystic Shield hand sanitizer bottles due to the presence of undeclared methanol.

    Product
    Mystic Shield PROTECTION, ALCOHOL ANTISEPTIC 70%, Topical Solution, Antiseptic Hand Rub, Non-sterile Solution, Extra strength Formula*, 8.45 fl. oz. (250 ml) bottle, Labeled with green or blue labels, Manufactured by Mystic Intl S.A. de C.V. UPC barcode: 7 87790 33952 6
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2667-2020·2020-07-29

    Becton Dickinson Recalls SafeStep Huber Needle Sets Due to Tubing Cracks

    Becton Dickinson is recalling SafeStep Huber Needle Sets because tubing may crack, risking chemical exposure, blood loss, or infection.

    Product
    SafeStep Huber Needle Set with GuardIVa Antimicrobial Hemostatic Dressing; Catalog Number CPA00040 (UDI 00801741143892)
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2663-2020·2020-07-29

    Becton Dickinson Recalls PowerLoc MAX Infusion Sets Due to Tubing Cracks

    Becton Dickinson is recalling PowerLoc MAX infusion sets because tubing may crack, risking leakage of chemicals or biohazard materials.

    Product
    PowerLoc MAX Power Injectable Infusion Set with GuardIVa Antimicrobial Hemostatic Dressing Port Access Kit; Catalog Numbers 2132010G (UDI 00801741095504), 2132015G (UDI 00801741095511), 2141910G (UDI 00801741095542), 2142010G (UDI 00801741085680), 2142015G (UDI 00801741085680)…
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2668-2020·2020-07-29

    Becton Dickinson SafeStep Huber Needle Set Recall for Tubing Cracks

    Becton Dickinson is recalling SafeStep Huber Needle Sets with GuardIVa Antimicrobial Hemostatic Dressing Port Access Kits due to potential tubing cracks that may cause leakage.

    Product
    SafeStep Huber Needle Set with GuardIVa Antimicrobial Hemostatic Dressing Port Access Kit; Catalog Numbers PA-0031G (UDI 00801741085666), PA-0031YNG (UDI 00801741085673), PA-0032G (UDI 00801741087639), PA-0033G (UDI 00801741096433)
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2665-2020·2020-07-29

    Becton Dickinson Recalls SafeStep Huber Needle Sets Due to Tubing Cracks

    Becton Dickinson is recalling SafeStep Huber Needle Sets because tubing may crack, risking leakage of chemicals or blood.

    Product
    SafeStep Huber Needle Set myPICK Port Access Kit; Catalog Numbers CPA00020A (UDI 00801741129827), CPA00042A (UDI 00801741182969), CPA00049 (UDI 00801741175695)
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2660-2020·2020-07-29

    Becton Dickinson Recalls PowerLoc MAX Infusion Sets Due to Tubing Cracks

    Becton Dickinson is recalling PowerLoc MAX infusion sets because tubing cracks may cause leakage of chemicals or biohazard materials.

    Product
    PowerLoc MAX Power Injectable Infusion Set AllPoints Port Access System; Catalog Numbers AN132075 (UDI 00801741118968), AN142010 (UDI 00801741119231), AN142010G (UDI 00801741119323), AN142075 (UDI 00801741119224)
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2664-2020·2020-07-29

    Becton Dickinson Recalls SafeStep Huber Needle Sets Due to Tubing Cracks

    Becton Dickinson is recalling SafeStep Huber Needle Sets because tubing may crack or break, risking leakage of chemicals or blood.

    Product
    SafeStep Huber Needle Set AllPoints Port Access System; Catalog Numbers AN152075 (UDI 00801741119484), AN152075G (UDI 00801741119583), AN162010 (UDI 00801741119682), AN162010G (UDI 00801741119446), AN162075 (UDI 00801741119675), AN162075G (UDI 00801741119439)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2676-2020·2020-07-29

    Boston Scientific Recalls IcePearl Cryoablation Needles Due to Surface Deterioration

    Boston Scientific is recalling 48 IcePearl 2.1 CX Cryoablation Needles because the needle surface deteriorated due to unexpected electrolysis during procedures.

    Product
    Ablation Galil Technology, IcePearl 2.1 CX Needle Cryoablation Needle, Prescription Only Galil Medicals 2.1 CX Cryoablation Needles are intended for cryoablative destruction of tissue during surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2670-2020·2020-07-29

    Becton Dickinson Recalls PowerLoc MAX Infusion Sets Due to Tubing Cracks

    Becton Dickinson is recalling PowerLoc MAX Power Injectable Infusion Sets because tubing may crack or break near the Luer or Y site, risking leakage of chemicals or blood.

    Product
    PowerLoc MAX Power Injectable Infusion Set; Catalog Numbers 0131910 (UDI 00801741047329), 0131915 (UDI 00801741047336), 0131975 (UDI 00801741047343), 0132010 (UDI 00801741047350), 0132015 (UDI 00801741047367), 0132075 (UDI 00801741047374), 0132210 (UDI 00801741047381), 0132215…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2643-2020·2020-07-29

    Wellspect Recalls LoFric Origo Urinary Catheters Due to Tip Defect

    Wellspect HealthCare is voluntarily recalling specific LoFric Origo urinary catheters because of a potential defect in the distal tip.

    Product
    LoFric Origo, Nelaton, 16in, FR10 urinary catheters
    Category
    Medical Device
    Distribution
    22 states
  • HighFDA (Devices)·Z-2674-2020·2020-07-29

    Boston Scientific Recalls IcePearl Cryoablation Needles Due to Surface Deterioration

    Boston Scientific is recalling IcePearl 2.0 CX 90 Cryoablation Needles because the needle surface deteriorated due to unexpected electrolysis during procedures.

    Product
    Ablation Galil Technology, IcePearl 2.0 CX 90 Cryoablation Needle, Prescription Only Galil Medicals 2.1 CX Cryoablation Needles are intended for cryoablative destruction of tissue during surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2673-2020·2020-07-29

    Medtronic Xomed IPC Software Upgrade Recalled for Speed Control Issue

    Medtronic Xomed is recalling IPC software upgrade v 2.7.3.0 because the M5 Microdebrider may rotate faster than the set value.

    Product
    Software 1898072 IPC upgrade v 2.7.3.0 - Product Usage: The IPC system is indicated for the incision/cutting removal, drilling and sawing of soft and hard tissue and bone in surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide