The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

31226–31250 of 88304

  • ModerateFDA (Food)·F-0156-2021·2020-12-16

    Chef Myron's Tangy Teriyaki Sauce Recalled for Gluten Mislabeling

    JMH International is recalling Chef Myron's Tangy Teriyaki Sauce because it contains wheat-derived ingredients despite a gluten-free claim.

    Product
    Chef Myron's Tangy Teriyaki Sauce, 64 FL OZ (1.89 L), Item # 400023221, 4 bottles/case
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0538-2021·2020-12-16

    Chromsystems Recalls MassChrom Amino Acid Analysis Plasma Control Level II

    Chromsystems Instruments & Chemicals GmbH is voluntarily recalling 363 vials of MassChrom Amino Acid Analysis Plasma Control Level II due to a Class II device defect.

    Product
    MassChrom Amino Acid Analysis Plasma Control Level II, Order No. 0472 - Product Usage: The kit is intended for amino acid metabolic screening, confirmation of a tentative diagnosis, and monitoring of treatment in individuals diagnosed with a metabolic disorder.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-0127-2021·2020-12-16

    Novocol Recalls Scandonest 3% Plain Due to Labeling Mix-Up

    Novocol Pharmaceutical is recalling 15,398 cartridges of Scandonest 3% Plain (Mepivacaine Hydrochloride) due to a label mix-up. The product is distributed nationwide.

    Product
    SCANDONEST 3% PLAIN — SCANDONEST 3% PLAIN (MEPIVACAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-0144-2021·2020-12-09

    Dole Organic Romaine Hearts Recalled Due to E. coli Contamination

    Dole Fresh Vegetables Inc. is recalling specific lots of Organic Romaine Hearts because pathogenic non-O157 E. coli STEC was found during routine sampling.

    Product
    Dole" Organic Romaine Hearts 3pk Organic Biologique) (UPC 0-71430-90061-1), Wild Harvest Organic Romaine Hearts, Net Wt 12 oz. (UPC 7-11535-50201-2),
    Category
    Food
    Distribution
    14 states
  • CriticalFDA (Drugs)·D-0111-2021·2020-12-09

    Lohxa Recalls Chlorhexidine Gluconate Oral Rinse Due to Bacterial Contamination

    Lohxa LLC is recalling Chlorhexidine Gluconate Oral Rinse USP, 0.12%, due to contamination with Burkholderia lata bacteria.

    Product
    Chlorhexidine Gluconate Oral Rinse USP, 0.12%, Alcohol Free, packaged in 15 mL unit does cups (barcode 7016602715), packaged in 50-count unit dose cups per carton, Rx only, Distributed by: Lohxa, Worcester, MA 01608, NDC 70166-027-15
    Category
    Drug
    Distribution
    2 states
  • CriticalFDA (Drugs)·D-0118-2021·2020-12-09

    MPM Medical Recalls REGENECARE HA Topical Anesthetic Due to Bacteria

    MPM Medical LLC is recalling REGENECARE HA topical anesthetic hydrogel because it was found to be contaminated with Burkholderia cepacia bacteria.

    Product
    REGENECARE HA — REGENECARE HA (LIDOCAINE HCL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0514-2021·2020-12-09

    Invacare PerfectO2 V Oxygen Concentrator Recalled for Fire and Explosion Risk

    Invacare is recalling 384,767 PerfectO2 V oxygen concentrators worldwide due to a defect that may cause self-extinguishing fires or cap explosions.

    Product
    Invacare PerfectO2 V Oxygen Concentrator- intended for patients with respiratory disorders requiring supplemental oxygen Model Numbers: IRC5PO2V (US), IRC5PO2VC (Canada), All World: IRC5PO2VAW, IRC5PO2VAWL2, IRC5PO2VAWL3, IRC5PO2VAWL4, IRC5PO2VAWL5
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0526-2021·2020-12-09

    CME America Recalls NeoThrive Syringe Pumps Due to Motor Wear

    CME America is recalling 4,182 NeoThrive syringe pumps because motor wear may cause under-infusion without alarms, and cleaning fluids may damage hardware.

    Product
    CME America T-Syringe Pump - NeoThrive - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0518-2021·2020-12-09

    Medtronic MiniMed 640G Insulin Pump Recalled for Missing Solder Battery Connection

    Medtronic is recalling MiniMed 640G insulin pumps because a missing solder battery connection could interrupt power. The recall covers specific serial numbers distributed in the U.S. and abroad.

    Product
    MiniMed 640G, insulin pump, Ref/Model # MMT-1711K, MMT-1752K, MMT-1752, Rx Only - Product Usage: indicated for the continuous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in persons requiring insulin.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0527-2021·2020-12-09

    CME America T-Syringe Pump Recall for Motor Wear and Fluid Damage

    CME America is recalling T34L PCA syringe pumps because motor wear may cause under-infusion without alarms, and cleaning fluids may damage hardware.

    Product
    CME America T-Syringe Pump - T34L PCA - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0145-2021·2020-12-09

    Tanimura & Antle Romaine Lettuce Recalled Due to E. coli O157:H7 Detection

    Tanimura & Antle is recalling specific lots of Romaine lettuce after Michigan state officials detected E. coli O157:H7 during routine sampling.

    Product
    Tanimura & Antle brand Romaine lettuce. 1 head 12,15,018 and 24 case Product of USA UPC: 2-27918 20314-9 Tanimura & Antle, Salinas, CA
    Category
    Food
    Distribution
    19 states
  • SevereFDA (Devices)·Z-0516-2021·2020-12-09

    Medtronic MiniMed 670G Insulin Pumps Recalled for Battery Connection Defect

    Medtronic is recalling 391 MiniMed 670G insulin pumps because a missing solder battery connection could interrupt power to the device.

    Product
    MiniMed 670G, insulin pump, Ref/Model # MMT-1760KPK, MMT-1762KCN, MMT-1762WWK - Product Usage: indicated for continuous or periodic monitoring of glucose levels in the fluid under the skin, and detecting possible low and high glucose episodes. When using a sensor and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0146-2021·2020-12-09

    Quantum Health Elderberry Liquid Extract Recalled for Salmonella Risk

    Quantum Inc. is recalling Quantum Health Elderberry liquid herbal extract due to potential Salmonella contamination. The product was distributed in Indiana, New Jersey, and New York.

    Product
    Quantum Health branded Elderberry liquid herbal extract dietary supplement is packaged in 2oz glass bottle, 12 bottles/case. Product is shelf stable with net wt. 2 fl oz/59 mL. UPC code: 0 46985 01625 4 Product is distributed by Quantum, Inc., Eugene, OR.
    Category
    Food
    Distribution
    3 states
  • HighFDA (Devices)·Z-0505-2021·2020-12-09

    Olympus Ultrasound Endoscope Recall for Updated Cleaning Instructions

    Olympus is recalling ultrasound endoscopes to update cleaning instructions and reduce the risk of patient infections.

    Product
    Olympus Ultrasound Endoscope, Model number: GF-UC160P-OL5 - Product Usage: used for diagnostic ultrasound imaging or fluid flow analysis of the human body.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0501-2021·2020-12-09

    Olympus Ultrasound Endoscope Recall for Updated Cleaning Instructions

    Olympus is recalling ultrasound endoscopes to update cleaning instructions and reduce the risk of patient infections.

    Product
    Olympus Ultrasound Endoscope, Model number :GF-UM20 - Product Usage: used with other supporting equipment for endoscopic real-time ultrasound imaging and endoscopic surgery within the gastrointestinal tract.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0141-2021·2020-12-09

    Minute Maid Watermelon Fruit Drink Recalled for Metal Contamination

    The Coca-Cola Company is recalling Minute Maid Watermelon Flavored Fruit Drink after a consumer reported a long piece of metal in the product.

    Product
    Minute Maid WATERMELON FLAVORED FRUIT DRINK WITH OTHER NATURAL FLAVORS 59 FL OZ (1.8 QT) 1.75 L PRODUCED FOR THE COCA-COLA COMPANY ATLANTA, GA Unit UPC 0 25000 04811 1, Case UPC 000-25000-04812-8
    Category
    Food
    Distribution
    9 states
  • HighFDA (Devices)·Z-0531-2021·2020-12-09

    Verathon BladderScan Prime Plus Probe Recall for Handle Cracking Risk

    Verathon is recalling 398 BladderScan Prime Plus Probes because a change in handle material and process may cause the handle to crack.

    Product
    BladderScan Prime Plus Probe REF 0570-0395 - Product Usage: intended to be used for measuring the urine volume in the bladder noninvasively.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0525-2021·2020-12-09

    CME America T-Syringe Pump Recalled for Motor Wear and Hardware Damage

    CME America is recalling T-Syringe Pumps because motor wear may cause silent under-infusion and cleaning fluids may crack hardware.

    Product
    CME America T-Syringe Pump -T34L - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous, subcutaneous, percutaneous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0510-2021·2020-12-09

    VEO Diagnostics Recalls ACCEL ELISA COVID-19 Antibody Test Kits

    VEO Diagnostics is recalling 15 ACCEL ELISA COVID-19 antibody test kits because the FDA removed their Emergency Use Authorization. Users should stop using the kits.

    Product
    ACCEL ELISA COVID-19 for the detection of total antibodies to SARS-CoV-2 Catalog AE301U Kit lots: PXCOV073020, PXCOV081220 Expiration dates: January 18, 2021 and January 26, 2021
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0147-2021·2020-12-09

    Tucson Tamale Blue Corn and Veggie Tamales Recalled for Plastic Contamination

    Tucson Tamale Wholesale Company is recalling Blue Corn & Veggie Tamales because plastic pieces were found in the tomato cans used to make them.

    Product
    Tucson Tamale Blue Corn & Veggie Tamales (2 Pack), 11 OZ (312g), plastic bag, UPC 8 53437 00234, Keep Frozen, 6 packs/box (case)
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0502-2021·2020-12-09

    Olympus Ultrasound Endoscope Recall for Updated Cleaning Instructions

    Olympus is recalling ultrasound endoscopes to update cleaning instructions and reduce the risk of patient infections.

    Product
    Olympus Ultrasound Endoscope, Model number: GF-UM130 - Product Usage: used with an Olympus Endoscopic Ultrasound Center, EVIS Video System Center, light source, documentation equipment, video monitor, Endo-Therapy accessories and other ancillary equipment for endoscopic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0517-2021·2020-12-09

    Medtronic MiniMed 630G Insulin Pump Recalled for Battery Connection Defect

    Medtronic is recalling 206 MiniMed 630G insulin pumps due to a missing solder battery connection that could interrupt power.

    Product
    MiniMed 630G with SmartGuard, insulin pump, Ref/Model # MMT-1754K, MMT-1714K, MMT-1755K - Product Usage: intended for continuous delivery of basal insulin (at user selectable rates) and administration of insulin boluses (in user selectable amounts) for the management of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0529-2021·2020-12-09

    CME America T-Syringe Pump Recalled for Motor Wear and Fluid Damage

    CME America is recalling 4,182 T-Syringe Pumps because motor wear may cause under-infusion without alarms, and cleaning fluids may crack hardware.

    Product
    CME America T-Syringe Pump - Ameritus 1st Enteral Pump - Product Usage: infusion of medications or fluids requiring continuous or intermittent delivery at precisely-controlled infusion rates through clinically acceptable routes of administration, including intravenous…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0148-2021·2020-12-09

    Tucson Tamale Blue Corn Veggie & Cheese Tamales Recalled for Plastic Contamination

    Tucson Tamale Wholesale Company is recalling specific lots of Blue Corn, Veggie & Cheese Tamales because plastic pieces were found in the tomato cans used to make them.

    Product
    Tucson Tamale Blue Corn, Veggie & Cheese Tamales (2 Pack), 11 OZ (312g), plastic bag, UPC 8 53437 00233, Keep Frozen, 6 packs/box (case)
    Category
    Food
    Distribution
    Distributed nationwide