The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

29026–29050 of 88304

  • HighFDA (Devices)·Z-1726-2021·2021-06-09

    ZVplasty Directional Cement Cannula recalled for inadequate sterilization

    Zavation is recalling 11 units of ZVplasty Directional Cement Cannula from lot 20061366 because products distributed as sterile may not have been adequately sterilized. The affected devices were distributed nationwide.

    Product
    ZVplasty Directional Cement Cannula (4 pieces per pack), REF VCF-1080-S4. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1779-2021·2021-06-09

    Oral surgery scrapers recalled due to possible inadequate sterilization

    Meta C.G.M. Spa recalls 27 units of REF 4890 SMARTSCRAPER oral surgery instruments distributed in Texas and Florida. The sterile-labeled devices may not have been adequately sterilized.

    Product
    REF 4890 SMARTSCRAPER CE0123, STERILE EO. Used in oral surgery.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1752-2021·2021-06-09

    InterV Kyphoplasty Spinal Devices Recalled for Inadequate Sterilization

    Zavation's InterV 10G FLEX Kyphoplasty spinal devices are recalled because they may not have been adequately sterilized. The recall affects 178 units distributed nationwide.

    Product
    InterV, 10G FLEX Kyphoplasty, REF Number: a) INTVM-15-FLDSK b) INTVM-20-FLDSK. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1738-2021·2021-06-09

    Zavation 10G Direct Double Bone Access Kit May Not Be Properly Sterilized

    Zavation recalled its 10G Direct Double Bone Access Kit used in orthopedic surgery because products distributed as sterile may not have been adequately sterilized, potentially exposing patients to infection.

    Product
    10G DIRECT DOUBLE BONE ACCESS KIT. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1739-2021·2021-06-09

    11G Direct Double Bone Access Kit May Not Be Adequately Sterilized

    Zavation's 11G Direct Double Bone Access Kit for spinal and orthopedic procedures may not have been adequately sterilized during manufacturing. Distributed nationwide, the non-sterile devices may pose infection risks to patients.

    Product
    11G DIRECT DOUBLE BONE ACCESS KIT. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0643-2021·2021-06-09

    Clio Yogurt Bars Recalled for Possible Metal Fragments

    Clio LLC is recalling Clio Yogurt Bar Mixed Berry Low Sugar Bar 50g x 10 retail 10-packs nationwide due to possible metal fragments in the product.

    Product
    Clio Yogurt Bar Mixed Berry Low Sugar Bar 50g x 10 Clio Retail 10-pack. UPC Code:854021008190
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1788-2021·2021-06-09

    Nimbus alternating-pressure mattress overlay system recall for inflation malfunction

    Getinge is recalling approximately 13,042 units of Nimbus 4 and Nimbus Professional alternating-pressure mattress overlays due to potential abnormal inflation that could impair pressure relief function.

    Product
    Nimbus 4 and Nimbus Professional Alternating-pressure bed mattress overlay system
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1736-2021·2021-06-09

    11G Beveled Trocars and Cannulas Recalled for Possible Inadequate Sterilization

    Zavation is recalling 11G Beveled Trocars/Cannulas for orthopedic and spinal procedures. These surgical instruments may not have been adequately sterilized, posing a potential safety risk.

    Product
    11G BEVELED TROCAR/CANNULA. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1755-2021·2021-06-09

    InterV 11G Kyphoplasty Kit Recall: Sterilization Defect May Increase Infection Risk

    Zavation is recalling 119 InterV 11G Kyphoplasty Kits distributed nationwide because they may not have been adequately sterilized, which could increase the risk of infection during spinal surgery.

    Product
    InterV 11G Kyphoplasty Kit, REF Numbers: a) INTVMN-10-DSK b) INTVMN-15-DSK c) INTVMN-15-DSKC d) INTVMN-20-DSK. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1694-2021·2021-06-09

    Hip implant cup liner recalled for mislabeling and wrong product in package

    Signature Orthopedics is recalling Logical cup liners (hip implants) due to mislabeling with incorrect products in the package. Affected devices may not be suitable for implantation.

    Product
    Logical cup liner - Product Usage: intended to replace a hip joint where bone stock is sufficient to support the implant.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1721-2021·2021-06-09

    Spinal Surgery Cement Delivery Cannula Kits Recalled for Potential Sterilization Failure

    Zavation is recalling ZVplasty Unipedicular Cement Delivery Cannula Kits distributed nationwide due to potential inadequate sterilization of sterile surgical devices.

    Product
    ZVplasty Unipedicular Cement Delivery Cannula Kit, 10 Gauge, REF VCF-SCDK. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1713-2021·2021-06-09

    Zavation surgical bone access kit recalled due to inadequate sterilization

    Zavation is recalling ZVplasty Direct Bipedicular Bone Access Kits because products distributed as sterile may not have been adequately sterilized. Patients who received these devices should contact their healthcare provider.

    Product
    ZVplasty Direct Bipedicular Bone Access Kit with Drill, 11 Gauge, REF VCF-DDBAK-11. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1704-2021·2021-06-09

    Zavation ZVplasty Direct Access Diamond Tip Trocar may not be sterile

    Zavation is recalling ZVplasty Direct Access Diamond Tip Trocar (REF VCF-1023) distributed nationwide because products marketed as sterile may not have been adequately sterilized. The device is used in orthopedic and spinal procedures.

    Product
    ZVplasty Direct Access Diamond Tip Trocar, 10 Gauge, REF VCF-1023. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0639-2021·2021-06-09

    Clio Yogurt Bars Recalled for Possible Metal Fragments

    Clio LLC is recalling Clio Yogurt Bar Berry Acai Less Sugar 10-packs due to the possible presence of metal fragments. The affected product was distributed nationwide.

    Product
    Clio Yogurt Bar Berry Acai Less Sugar 45g x 10 Clio Retail 10-pack. UPC Code: 854021008244
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1792-2021·2021-06-09

    Zimmer Natural Nail cephalomedullary device angle mismatch recall

    Zimmer GmbH is recalling its Cephalomedullary Short Nail due to potential mix-up between 125 and 130 degree CCD angle versions. Eight units with Lot 3020731 are affected and distributed to CA, GA, KY, MD, and internationally.

    Product
    Zimmer Natural Nail -ZNN Cephalomedullary Short Nail 11.5 mm X 21.5 cm 125 CCD Left Ti-6Al-4V Alloy- intended for temporary fracture fixation and stabilization of the bone Item Number: 47-2493-211-11
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1692-2021·2021-06-09

    Draeger Babylog VN600 Critical Care Ventilators Recalled for Software Defects

    Draeger Medical is recalling Babylog VN600 ventilators due to three software issues: unexpected unit restarts, incorrect oxygen-level alarms, and failure of the automated weaning protocol. These defects could affect patient care and safety.

    Product
    Critical Care Ventilator, Catalog Number(s): 8422200: Babylog VN600 - Product Usage: used for treating patients who require temporary or longer term respiratory support for different medical reasons.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1741-2021·2021-06-09

    Zavation Orthopedic Cement Delivery Kit Recalled for Inadequate Sterilization

    Zavation is recalling 10G Double Cement Delivery Kits used in orthopedic and spinal procedures due to potential inadequate sterilization, creating a risk of surgical site infection.

    Product
    10G DOUBLE CEMENT DELIVERY KIT (8 FILLERS). For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1723-2021·2021-06-09

    ZVplasty Biopsy Device Recalled Due to Inadequate Sterilization

    Zavation's ZVplasty Biopsy Device (11 Gauge, lot 20061370) is being recalled because distributed units may not have been adequately sterilized. The 34 affected units were distributed nationwide.

    Product
    ZVplasty Biopsy Device, 11 Gauge, REF VCF-1010-11. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1706-2021·2021-06-09

    ZVplasty Spinal Bone Access Kit Recall Due to Inadequate Sterilization

    Zavation is recalling ZVplasty Direct Bipedicular Bone Access Kits due to inadequate sterilization. Products distributed as sterile nationwide may pose infection risk if used in spinal procedures.

    Product
    ZVplasty Direct Bipedicular Bone Access Kit with Drill, 10 Gauge, VCF-DDBAK. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1757-2021·2021-06-09

    ZVplasty System spinal implant devices recalled for inadequate sterilization

    Zavation is recalling 31 ZVplasty System spinal implant devices that may not have been adequately sterilized. Patients who received these implants should contact their physician.

    Product
    ZVplasty System, 10mm, Pat# VCF-1010-2. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1735-2021·2021-06-09

    Orthopedic Cement Delivery Kits Recalled Due to Sterilization Concerns

    Zavation's 10G cement delivery kits for spinal procedures may not be adequately sterilized despite being marketed as sterile. Patients and healthcare providers should contact Zavation regarding potentially affected units.

    Product
    10G SINGLE CEMENT DELIVERY KIT (5 FILLERS). For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1725-2021·2021-06-09

    ZVplasty Directional Cement Cannula Long may lack adequate sterilization

    Zavation is recalling 27 units of ZVplasty Directional Cement Cannula Long (Lot 20061365) used in orthopedic and spinal procedures due to inadequate sterilization. Products were distributed nationwide as sterile but may not have undergone proper sterilization processing.

    Product
    ZVplasty Directional Cement Cannula Long, REF VCF-1080-L. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1747-2021·2021-06-09

    Zavation 10G Cement Delivery Cannula Recalled for Inadequate Sterilization

    Zavation is recalling its 10G Cement Delivery Cannula used in orthopedic and spinal procedures nationwide due to products distributed as sterile not being adequately sterilized.

    Product
    10G CEMENT DELIVERY CANNULA. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1707-2021·2021-06-09

    ZVplasty Surgical Bone Access Kit Recalled for Inadequate Sterilization

    Zavation is recalling ZVplasty Direct Bipedicular Bone Access Kits because products distributed as sterile may not have been adequately sterilized. Affected lot numbers 19113043 and 20041107 were distributed nationwide.

    Product
    ZVplasty, Direct Bipedicular, Bone Access Kit with Coxaial Cannula, REF VCF-DDSKbd. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide