The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

28976–29000 of 88304

  • ModerateFDA (Food)·F-0657-2021·2021-06-16

    Garlic Alfredo Sauce Recall Due to Non-Food Grade Anti-Foamer

    Kerry Inc. is recalling Garlic Alfredo Sauce (product code 20607981) because the product was manufactured with a non-food grade anti-foamer ingredient. The affected sauce was distributed to AZ, CO, OK, TX, and WI.

    Product
    Garlic Alfredo Sauce. Product code 20607981. Keep Frozen. Net Wt. 30 lb. (13.61KG) Distributed By: Kerry Inc., Beloit, WI 53511.
    Category
    Food
    Distribution
    5 states
  • ModerateFDA (Drugs)·D-0605-2021·2021-06-16

    DELFLEX Peritoneal Dialysis Solution Recalled for Temperature Abuse

    Fresenius Medical Care is recalling DELFLEX Peritoneal Dialysis Solution nationwide because the product was exposed to temperatures outside specified limits during distribution, which may compromise sterility or safety.

    Product
    DELFLEX — DELFLEX (DEXTROSE MONOHYDRATE, SODIUM CHLORIDE, SODIUM LACTATE, CALCIUM CHLORIDE, MAGNESIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0603-2021·2021-06-16

    Sodium Chloride 0.9% USP 1000 mL Recall for Temperature Abuse

    Fresenius Medical Care is recalling Sodium Chloride 0.9% USP 1000 mL injection (Lot #20NG02095, expiration October 2021) because the product was exposed to temperatures outside specified limits, which may affect its sterility and safety.

    Product
    Sodium Chloride 0.9%, USP, 1000 mL, Mfg by: Fresenius Medical Care North America, Waltham, MA 02451, NDC 46163-0300-10
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0630-2021·2021-06-16

    Levetiracetam Tablets 250 mg Recalled for Incorrect Barcode

    McKesson Corporation is recalling Levetiracetam Tablets USP 250 mg due to a barcode error that could cause some units to be misread as Naproxen 500 mg, although the product label itself is correct.

    Product
    Levetiracetam Tablets USP, 250 mg UD 100 Tablets (10x10) boxes, Rx Only, Distributed By: McKesson Corporation 4971 Southridge Blvd., Suite 101 Memphis, TN 38141 Manufactured by: Aurobindo Pharma Limited Hyderabad-500 090, India NDC 63739-795-10
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0662-2021·2021-06-16

    Glaceau Vitaminwater XXX mislabeled; may contain sugar instead of zero sugar

    The Coca-Cola Company is recalling Glaceau Vitaminwater XXX acai-blueberry-pomegranate labeled as zero sugar because an incorrect label was used and the product may actually contain sugar.

    Product
    Glaceau Vitaminwater XXX labeled to be Glaceau Vitaminwater Zero Sugar XXX acai-blueberry-pomegranate, 16.9 FL OZ, made for glaceau, Atlanta, GA
    Category
    Food
    Distribution
    12 states
  • ModerateFDA (Devices)·Z-1835-2021·2021-06-16

    Medical microscope slide stainer recalled due to defective pump tubing

    Hardy Diagnostics is recalling the Quickslide GramPro 1 Automated Gram Stanier due to defective tubing in the pump mechanism that could cause device malfunction.

    Product
    Quickslide GramPro 1 Automated Gram Stanier is a microscope slide stainer.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1829-2021·2021-06-16

    VIA Microcatheter VIA 21 Recalled for International Labeling Error

    MICROVENTION INC. is recalling VIA Microcatheter VIA 21 units (Lot 19110403M) because they were shipped with international labeling instead of FDA-cleared US labeling.

    Product
    VIA Microcatheter VIA 21 REF VIA-21-154-01 - Product Usage: is a single lumen catheter designed to be introduced over a steerable guidewire into the vasculature.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-0607-2021·2021-06-16

    DELFLEX Peritoneal Dialysis Solution Recalled Due to Temperature Abuse

    Fresenius Medical Care is recalling DELFLEX Peritoneal Dialysis Solution (1.5% Dextrose with exchange set) distributed nationwide because the product was exposed to temperatures outside specified limits.

    Product
    DELFLEX — DELFLEX (DEXTROSE MONOHYDRATE, SODIUM CHLORIDE, SODIUM LACTATE, CALCIUM CHLORIDE, MAGNESIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1828-2021·2021-06-16

    VIA Microcatheter recalled due to incorrect international labeling shipped to US

    MicroVention is recalling certain VIA Microcatheter units that were shipped with international labeling instead of US-approved labeling. Affected units were distributed across six US states.

    Product
    VIA Microcatheter VIA 17 REF VIA-17-154-01 - Product Usage: is a single lumen catheter designed to be introduced over a steerable guidewire into the vasculature.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-0608-2021·2021-06-16

    DELFLEX Peritoneal Dialysis Solution Recalled for Temperature Exposure

    Fresenius Medical Care is recalling DELFLEX Peritoneal Dialysis Solution (39 cases nationwide) because the product was exposed to temperatures outside specified limits during storage or distribution.

    Product
    DELFLEX — DELFLEX (DEXTROSE MONOHYDRATE, SODIUM CHLORIDE, SODIUM LACTATE, CALCIUM CHLORIDE, MAGNESIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-0606-2021·2021-06-16

    DELFELX Peritoneal Dialysis Solution Recalled Due to Temperature Abuse

    Fresenius Medical Care is recalling 49 cases of DELFELX Peritoneal Dialysis Solution (5000 mL, 4.25% Dextrose) because the product was exposed to temperatures outside specified limits.

    Product
    DELFELX Peritoneal Dialysis Solution with 4.25% Dextrose, Low Magnesium, Low Calcium, 5000 mL, Fresenius Medical Care, Waltham, MA 02451, NDC 49230-0212-50
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1651-2021·2021-06-09

    Alaris Infusion Pump Module Bezel Repair Parts Recalled for Separation Risk

    FDA recalls 22 serviced Alaris Model 8100 infusion pump units with bezel components that may crack or separate, risking free flow, over-infusion, under-infusion, or treatment interruption. Units distributed to Indiana and Texas between September 2020 and February 2021.

    Product
    Alaris Infusion Pump Module, Model 8100, serviced/repaired by The Biomed Guys, with the impacted bezel repair part, TIPA-8100-4410 / Alaris 8100 Bezel.
    Category
    Medical Device
    Distribution
    2 states
  • CriticalFDA (Drugs)·D-0627-2021·2021-06-09

    Pfizer Lidocaine and Bupivacaine Injection Label Mix-Up Recall

    Pfizer has recalled 139,050 vials of injectable anesthetic medications due to a label mix-up: some vials labeled as Lidocaine contain Bupivacaine, and some labeled as Bupivacaine contain Lidocaine. Patients and healthcare providers should verify medication identity before use.

    Product
    LIDOCAINE HYDROCHLORIDE — LIDOCAINE HYDROCHLORIDE (LIDOCAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1620-2021·2021-06-09

    Leccurate SARS-CoV-2 Antigen Test Kit Recalled: Not FDA-Approved for U.S. Distribution

    The Leccurate SARS-CoV-2 Antigen Rapid Test Kit is being recalled because it was not authorized, cleared, or approved for marketing in the United States. Approximately 8.4 million units were distributed worldwide, including to U.S. states and territories.

    Product
    Leccurate SARS-CoV-2, Antigen Rapid Test Kit (Colloidal Gold Immunochromatography), 1 test, IVD. for the qualitative detection of antigen SARS-CoV-2 in clinical samples (nasal swab).
    Category
    Medical Device
    Distribution
    5 states
  • SevereFDA (Food)·F-0655-2021·2021-06-09

    Chicken Street Taco Kits Recalled for Undeclared Egg Allergen

    Reser's Fine Foods is recalling Chicken Street Taco Kits because the Chipotle Crema component contains egg that is not declared on the label, posing a risk to consumers with egg allergies.

    Product
    ***Chicken Street Taco Kit with Trays, item # 13454.38080, Refrigerated product, 2/4.985 lbs. kits in each case. Distributed by Reser's Fine Foods, Topeka, KS. ***Homechef Chicken Street Taco Kit with Trays, item # 40134.30435, Refrigerated product, 2/4.985 lbs. kits in each…
    Category
    Food
    Distribution
    24 states
  • SevereFDA (Drugs)·D-0626-2021·2021-06-09

    Bupivacaine and Lidocaine Injection Vials Recalled for Label Mix-Up

    Pfizer is recalling 163,957 vials of 0.5% Bupivacaine Hydrochloride Injection due to a label mix-up where some vials labeled as bupivacaine may contain lidocaine, and vials labeled as lidocaine may contain bupivacaine. The mix-up could lead to patients receiving the wrong local anesthetic.

    Product
    BUPIVACAINE HYDROCHLORIDE — BUPIVACAINE HYDROCHLORIDE (BUPIVACAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0645-2021·2021-06-09

    Peppa Pig Chocolate Chip Cookies Recalled for Undeclared Egg Allergen

    PRIMARY COLORS DESIGN CORP is recalling Peppa Pig brand chocolate chip cookies due to undeclared egg allergen on the packaging. The recall affects 294 boxes distributed in Georgia, lot number 091820.

    Product
    Peppa Pig brand chocolate chip cookies. One 7 oz bag per box- 6 boxes per case
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-0646-2021·2021-06-09

    Giant Eagle Chicken Street Taco Kit recalled for undeclared egg allergen

    Giant Eagle is recalling Chicken Street Taco Kit packages due to undeclared egg allergen. The affected product was distributed to stores in PA, WV, OH, and IN.

    Product
    Giant Eagle Chicken Street Taco Kit; 20 oz (1 lbs 4 oz) Individual Units, PLU Code beginning 256598 00000
    Category
    Food
    Distribution
    4 states
  • SevereFDA (Devices)·Z-1619-2021·2021-06-09

    Leccurate COVID-19 Antibody Test Kit Recalled for Unauthorized U.S. Distribution

    LEPU Medical has recalled the Leccurate SARS-CoV-2 Antibody Rapid Test Kit because it is not authorized, cleared, or approved for marketing in the U.S. Approximately 8.4 million units have been distributed worldwide.

    Product
    Leccurate SARS-CoV-2, Antibody Rapid Test Kit (Colloidal Gold Immunochromatography), 1 test, IVD. for qualitative detection of IgM and/or IgG antibodies to SARS-CoV-2 in human serum, plasma and venipuncture whole blood for use as an aid in identifying individuals with an…
    Category
    Medical Device
    Distribution
    5 states
  • SevereFDA (Food)·F-0633-2021·2021-06-09

    Mahayograj Guggulu Dietary Supplement Recalled for High Lead Contamination

    Garry N Sun USA Inc. is recalling Mahayograj Guggulu dietary supplement capsules and powder due to high lead levels detected in a consumer sample. The product was distributed across multiple U.S. states and Canada.

    Product
    Mahayograj Guggulu; 120 Vegetarian Capsules, 1/2 lb. bags of powder Dietary Supplement, 1030 Matley Lane, Unit A Reno, NV 89502 Serving size: 2 capsule Servings per container: 60 Proprietary Blend - 500 mg Certified Organic Distributed by Garry N Sun USA
    Category
    Food
    Distribution
    11 states
  • HighFDA (Devices)·Z-1712-2021·2021-06-09

    ZVplasty Direct Access Trocar Recalled for Inadequate Sterilization

    Zavation is recalling ZVplasty Direct Access Diamond Tip Trocars (11 Gauge) because some units may not be adequately sterilized. These surgical instruments are used in orthopedic and spinal procedures.

    Product
    ZVplasty Direct Access Diamond Tip Trocar, 11 Gauge, REF VCF-1023-11. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1753-2021·2021-06-09

    Orthopedic Spinal Surgery Kit Recalled for Inadequate Sterilization

    Zavation is recalling InterV CurvePlus surgical kits because products distributed as sterile may not have been adequately sterilized. 36 units were distributed nationwide.

    Product
    InterV CurvePlus Kit, REF Numbers: a) INTVMC-15-FLDSK b) INTVMC-20-FLDSK. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1789-2021·2021-06-09

    Terumo HX2 and TCM Temperature Management Systems Recalled for Cleaning Protocol Issues

    Terumo recalled the HX2 and TCM temperature management systems used in cardiac surgery due to inability to validate an updated cleaning protocol. Users should discontinue use and properly dispose of affected devices.

    Product
    The Terumo HX2 Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery. The system consists of a water tank, circulating pumps…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1775-2021·2021-06-09

    Synapse Cardiovascular software may incorrectly reuse patient database identifiers

    Fujifilm's Synapse Cardiovascular software versions 6.0.4 to 6.2.1 contain a defect in the Advanced Reporting function where previously assigned patient database identification numbers can be reused for new patients when specific patient merge operations are executed.

    Product
    Synapse Cardiovascular (Synapse CV). Software Versions: 6.0 to 6.2.1 The Synapse Cardiovascular image is a management and reporting system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1763-2021·2021-06-09

    ZVplasty 10G FLEX Kyphoplasty Spinal Device Recall Due to Sterilization Failure

    Zavation is recalling 19 units of ZVplasty 10G FLEX KYPHOPLASTY spinal devices because distributed units may not have been adequately sterilized, posing infection risk to patients.

    Product
    ZVplasty 10G, FLEX KYPHOPLASTY, REF VCF-1015-FLEX. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide