The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

27701–27725 of 88183

  • HighFDA (Devices)·Z-2466-2021·2021-09-22

    BD Alaris Infusion Pump Buerette Set Connector Valve Occlusion Issues

    BD Alaris needle-free connector valves in Buerette Sets may develop occlusions, difficulty flushing, or flow issues that could delay patient therapy. The product was distributed worldwide across all US states and multiple countries.

    Product
    BD Alaris Pump Infusion Buerette Set Smallbore Tubing Smartsite Port (Burette) 3 SmartSite Y-Sites, REF: 2441-0006
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2453-2021·2021-09-22

    Configura Advance Mobility Chairs Recalled for Potential Backrest Detachment

    Accora Inc is recalling multiple Configura Advance Chair models due to a potential defect where the backrest may detach, creating a fall risk for users.

    Product
    Configura Advance Chair, Model Number: CHAIR-0-SC1-030; Advance Chair, 100mm Castors, Std Backrest, Manual; Serial Numbers: 10001-SC1-20 to 10483-SC1-20; 10001-SC1-21 to 10224-SC1-21; 10231-SC1-21 to 10456-SC1-21; 10481-SC1-21 to 10570-SC1-21. Model Number: CHAIR-0-SC2-030…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0794-2021·2021-09-22

    Oxycodone Hydrochloride Tablets Recalled for Foreign Tablet Contamination

    Rhodes Pharmaceuticals is recalling Oxycodone Hydrochloride 10 mg tablets (Lot # WP5K0Y) distributed nationwide after a foreign Hydrochlorothiazide/Lisinopril tablet was found in one bottle.

    Product
    OXYCODONE HYDROCHLORIDE — OXYCODONE HYDROCHLORIDE (OXYCODONE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0984-2021·2021-09-22

    Albanese Mini Gummi Butterflies recalled for undeclared dietary supplement

    Albanese World's Best Mini Gummi Butterflies (7.5oz) contain comingled Olly Sleep dietary supplement that may cause drowsiness. Consumers should not eat the product.

    Product
    Albanese World's Best Mini Gummi Butterflies 7.5oz UPC 634418523525
    Category
    Food
    Distribution
    2 states
  • HighFDA (Food)·F-0964-2021·2021-09-22

    Full Tilt Ice Cream Backyard Mint Chip Recall for Pasteurization Issue

    Full Tilt Ice Cream is recalling Backyard Mint Chip ice cream in 16oz pints and 3-gallon tubs because the ice cream mix did not meet pasteurization specifications. The product was distributed in Washington.

    Product
    Backyard mint chip, Full Tilt Ice Cream brand, packaged in 16oz pre packed pints and and 3 gallon tubs. UPC on pint container: 00856962005054.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-0980-2021·2021-09-22

    Vita Aid SynerClear Chocolate Powder Recalled for Undeclared Milk

    Naturo Aid Pharmaceutical Inc. is recalling Vita Aid SynerClear (Chocolate) powder because it may contain undeclared milk residue, which poses a hazard to consumers with milk allergies.

    Product
    Vita Aid SynerClear (Chocolate), VA-012. The product is a powder, packaged in a plastic bottle and a white cap, with a net weight of 650g.
    Category
    Food
    Distribution
    10 states
  • HighFDA (Devices)·Z-2447-2021·2021-09-22

    MR MAGNETOM Imaging Systems Risk Data Loss in Treatment Planning

    Siemens MR MAGNETOM imaging systems may lose treatment planning data when editing structure sets after reopening a saved study, resulting in incomplete treatment plans being transmitted to planning systems.

    Product
    MR MAGNETOM Systems with RT Image Suite with syngo MR VA20A, VA30A and VA31A with license SW-Key CT_RT_IMA_SUITE_SYNTHETIC_CT Material Numbers: 11060815
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2464-2021·2021-09-22

    Needle-Free Burette Set Valves Recalled for Occlusion and Flow Issues

    BD ADD-ON Burette Set V/NV Needle-Free Valves may experience occlusions or flow issues that could delay therapy. CAREFUSION recalled 44,120 units with this defect.

    Product
    BD ADD-ON Burette Set V/NV Needle-Free Valve, REF: 82113E-0006
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2459-2021·2021-09-22

    BD Alaris Infusion Pump Buerette Sets Needle-Free Connector Valve Issues

    BD Alaris Pump Infusion Buerette Sets with needle-free connector valves may experience flushing difficulties, flow issues, or occlusions that could delay therapy delivery. No illnesses or injuries have been reported.

    Product
    BD Alaris Pump Infusion Buerette Set 0.2 Micron Filter Smallbore Tubing SmartSite Port (Burette) SmartSite Y-Site, REF: 10015012; BD Alaris Pump Infusion Buerette Set Ball Valve Smallbore Tubing Smartsite Port (Burette) SmartSite Y-Site, REF: 10817920; BD Alaris Pump Infusion…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2448-2021·2021-09-22

    Pentax Medical Colonoscopes and Upper GI Scopes Updated Reprocessing Instructions

    Pentax is updating reprocessing instructions for over 28,000 colonoscopes and Upper GI scopes distributed nationwide between 2014 and 2021. Healthcare facilities should implement the updated procedures provided by the manufacturer.

    Product
    Colonoscope Family # 1-Pentax Video Colonoscopes (EC Family) with One Instrument Channel and a Water Jet Channel Models: EC-2990Li, EC-3490Li, EC-3890Li, EC-3490TLi, EC-3490LK, EC-3890LK, EC3890LZi, EC34-i10L, EC38-i10L; Colonoscope Family # 2-Pentax Video Colonoscopes with…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2477-2021·2021-09-22

    Lyra Direct SARS-CoV-2 Assay Instructions Revised for False Negative Risk

    The Lyra Direct SARS-CoV-2 assay can produce false negatives on certain PCR machines when specimens have high viral loads. Revised instructions address this diagnostic failure risk affecting approximately 81,910 kits distributed worldwide.

    Product
    Lyra Direct SARS-CoV-2 Assay Emergency Use Authorization- Ref: M124. The Lyra Direct SARS-CoV-2 Assay is a real-time RT-PCR assay intended for the qualitative detection of nucleic acid from SARS-CoV-2 in nasal (NS), nasopharyngeal (NP), or oropharyngeal (OP) direct swab…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2452-2021·2021-09-22

    Cellex COVID-19 Antigen Test kits recalled for lacking FDA emergency use authorization

    Cellex is recalling approximately 44,821 units of its qSARS-CoV-2 Antigen Rapid Test due to lack of FDA emergency use authorization. The test was distributed nationwide in California, Florida, Texas, and Wisconsin.

    Product
    Cellex qSARS-Cov-2 Antigen Rapid Test, 25 tests/box, submitted as EUA202955 "declined to issue"
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2454-2021·2021-09-22

    Extension Set SMALLBORE Tubing with SmartSite Valves Recalled for Flushing Issues

    BD Extension Set SMALLBORE Tubing with SmartSite Valves (REF: 20019E) is being recalled due to flushing difficulties, flow issues, and occlusions that could delay therapy. Over 1.4 million units distributed worldwide are affected.

    Product
    BD Extension Set SMALLBORE Tubing with 2 SmartSite VALVES, REF: 20019E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2462-2021·2021-09-22

    BD Gravity Burette Set Needle-Free Connector Valves Recalled for Flow Issues

    CAREFUSION is recalling BD Gravity Burette Sets with needle-free connector valves that may develop flow restrictions and blockages, potentially delaying medication delivery. Approximately 29,130 units were distributed.

    Product
    BD Gravity Burette Set 60 DP 3 SmartSite VALVES BALL VALVE DRIP CHAMBER, REF: 10012564
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2463-2021·2021-09-22

    BD Gravity IV needle-free connector valve occlusion risk

    BD Gravity IV needle-free connector valves may develop flow issues and partial or total occlusions that could delay therapy. The recall affects 24,360 units distributed worldwide.

    Product
    BD Gravity IV Set 3-port Closed Manifold Back Check Valve 3 Needle-Free Y-sites, REF: CM42500E-07; BD Gravity IV Set 3-port Closed Stopock Manifold Back Check Valve 2 Needle-Free Y-sites, REF: CS42522E-07; BD GRAVITY 10 DP V/NV CHECK VALVE 3-WAY STOPCOCK 4 Smartsite VALVES &…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2445-2021·2021-09-22

    Radiation Therapy Software Risk: Data Loss in Treatment Planning

    Siemens radiation therapy planning software may lose data when editing treatment structures. Incomplete structure sets could be sent to the treatment planning system, affecting treatment plan accuracy.

    Product
    syngo.via RT Image Suite with syngo.via VB30, VB40, VB50 and VB60- Intended for Radiation Therapy Treatment Material Number: 10496180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0974-2021·2021-09-22

    Full Tilt Coffee Oreo Ice Cream Recall for Inadequate Pasteurization

    Full Tilt Ice Cream, LLC is recalling Coffee Oreo ice cream in 3-gallon tubs distributed in Washington because the ice cream mix did not meet pasteurization specifications.

    Product
    Coffee Oreo, Full Tilt Ice Cream brand, packaged in 3 gallon tubs. No UPC.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-0968-2021·2021-09-22

    Full Tilt Huckleberry Chip Ice Cream Recall Due to Pasteurization Failure

    Full Tilt Ice Cream is recalling Huckleberry Chip ice cream in 3-gallon tubs distributed in Washington because the ice cream mix did not meet pasteurization specifications, posing a food safety risk.

    Product
    Huckleberry Chip, Full Tilt Ice Cream brand, packaged in 3 gallon tubs. No UPC.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Devices)·Z-2473-2021·2021-09-22

    McKesson Lap Sponges Recalled for Failed Sterilization Indicator

    Cypress Medical Products is recalling one case of McKesson Lap Sponges due to a failed sterilization indicator that did not change from red to blue, compromising verification of proper sterilization.

    Product
    McKesson Lap Sponge, X-Ray Detectable 12"x 12", 5/pack, Sterile McKesson Part # 16-2112121
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2471-2021·2021-09-22

    Siemens ACUSON Juniper ultrasound system recalled for intermittent power supply failure

    Siemens Medical Solutions USA is recalling 15 ACUSON Juniper Diagnostic Ultrasound Systems worldwide due to intermittent power supply failures that render the devices inoperable. No injuries or illnesses have been reported.

    Product
    ACUSON Juniper Diagnostic Ultrasound System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0983-2021·2021-09-22

    Trader Joe's Raw California Walnut Baking Pieces Mispackaging Recall

    Trader Joe's Raw California Walnut Baking Pieces have been recalled due to mispackaging. Bags labeled as walnut pieces contain a mix of cashews, macadamia nuts, and walnuts.

    Product
    Trader Joe's Nuts Raw California Walnut Baking Pieces NET WT. 16 OZ (1 LB) 454g SKU# 51934-89685 UPC 0051 9342 Contains Walnuts Dist & Sold Exclusive By: Trader Joe's, Monrovia, CA 91016
    Category
    Food
    Distribution
    7 states
  • HighFDA (Devices)·Z-2474-2021·2021-09-22

    Philips Allura Xper X-ray imaging system failures at 480V power supply

    Four Philips Allura Xper X-ray imaging systems may fail prematurely when powered at 480V hospital mains, causing coil overheating and reduced imaging performance.

    Product
    The Allura Xper series is intended for use on human patients to perform: "Vascular, cardiovascular and neurovascular imaging applications, including diagnostic, interventional and minimally invasive procedures. This includes, e.g., peripheral, cerebral, thoracic and abdominal…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0981-2021·2021-09-22

    Roasted Red Pepper Flour Wraps Recall Due to Undeclared Wheat

    Tortilleria Sonora is recalling Roasted Red Pepper 12" Supreme Flour Wraps because the product contains undeclared wheat. The case label lists enriched flour but fails to disclose wheat presence, posing a risk to consumers with wheat allergies.

    Product
    Roasted Red Pepper 12" Supreme Flour Wraps, Tortilleria Sonora, Inc.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Devices)·Z-2468-2021·2021-09-22

    BD Needle-Free Bag Access Valves Recalled for Flow Obstruction

    BD SmartSite needle-free valves may become obstructed, preventing proper fluid flow in medical infusions. The FDA recalls over 295,000 units due to risk of therapy delays.

    Product
    BD SmartSite Bag Access Device Needle-Free Valve, REF: 2300E; BD Bag access Device with 1 Check Valve And Needle Free Valve, REF: 2309E-0006
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2475-2021·2021-09-22

    Philips Allura Xper Imaging System Overheating and Malfunction Recall

    Philips Allura Xper imaging systems may fail early when supplied with 480V, causing coil overheating and burning smell. When the system fails, X-ray imaging capability is reduced to emergency mode only.

    Product
    The Allura Xper series is intended for use on human patients to perform: "Vascular, cardiovascular and neurovascular imaging applications, including diagnostic, interventional and minimally invasive procedures. This includes, e.g., peripheral, cerebral, thoracic and abdominal…
    Category
    Medical Device
    Distribution
    Distributed nationwide