The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

25326–25350 of 88183

  • SevereFDA (Food)·F-0778-2022·2022-03-02

    Kroger American Blend Lettuce Recalled for Listeria Contamination Risk

    Dole Fresh Vegetables recalls Kroger American Blend lettuce due to Listeria found on harvest equipment. Affected products distributed across the US and Canada have best-by dates from December 22, 2021 to January 9, 2022.

    Product
    Kroger 12 oz American Blend UPC: 0-11110-91041-7 SKU: 3003
    Category
    Food
    Distribution
    37 states
  • SevereFDA (Food)·F-0802-2022·2022-03-02

    Weis Original Potato Salad recalled for undeclared milk allergen

    Garden-Fresh Foods, Inc. is voluntarily recalling Weis Original Potato Salad due to undeclared milk. The product was distributed in six states; consumers with milk allergies should not consume affected packages.

    Product
    Weis Original Potato Salad, Net Wt 64 oz (4 lb) 1.81kg. UPC 41497-19347. Keep Refrigerated
    Category
    Food
    Distribution
    6 states
  • SevereFDA (Food)·F-0769-2022·2022-03-02

    Dole Garden Salad Recalled Due to Listeria Contamination in Harvest Equipment

    Dole Fresh Vegetables Inc is recalling multiple sizes of Dole Garden Salad due to Listeria monocytogenes found in harvest equipment used during lettuce harvesting.

    Product
    Dole 12 oz Garden Salad / Salade du Jardin UPC: 0-71430-01135-5 SKU: 2673 Dole 2 lb Garden Salad UPC: 0-71430-01137-9 SKU 2504 Dole 24 oz Value Size Garden Salad UPC: 0-71430-01136-2 SKU 2109
    Category
    Food
    Distribution
    37 states
  • SevereFDA (Food)·F-0779-2022·2022-03-02

    Dole Fresh Vegetables Recalls Kroger Salad Mix for Listeria

    Dole Fresh Vegetables recalled Kroger 12 oz Classic Garden salad mix after Listeria monocytogenes was found in harvest equipment. Affected products have codes beginning with W and best-by dates from December 22, 2021 through January 9, 2022.

    Product
    Kroger 12 oz Classic Garden UPC: 0-11110-91036-3 SKU: 3007
    Category
    Food
    Distribution
    37 states
  • SevereFDA (Food)·F-0751-2022·2022-03-02

    Dole Shredded Lettuce Recalled Due to Listeria Monocytogenes Contamination

    Dole Fresh Vegetables Inc is recalling 8oz packages of shredded lettuce because harvest equipment was found to contain Listeria monocytogenes. The recalled products have best-by dates from December 23, 2021 through January 8, 2022.

    Product
    Dole 8oz Shredded Lettuce UPC: 0-71430-01065-5 SKU: 2029
    Category
    Food
    Distribution
    37 states
  • SevereFDA (Food)·F-0777-2022·2022-03-02

    Dole Teriyaki Pineapple Kit recalled for Listeria contamination

    Dole is recalling certain Teriyaki Pineapple Kits due to Listeria monocytogenes detected in harvest equipment. Affected products have codes beginning with W and best-by dates from December 22, 2021 through January 9, 2022.

    Product
    Dole 9.8 oz Chopped Teriyaki Pineapple Kit UPC: 0-71430-00100-4 SKU: 791 Dole 9.8 oz Chopped Teriyaki Pineapple Kit / Teriyaki A L'ananas UPC: ¿0-71430-00182-0 SKU 1014
    Category
    Food
    Distribution
    37 states
  • HighFDA (Devices)·Z-0672-2022·2022-03-02

    Biomet Shoulder Implant Stem Recalled for Inadequate Coating Adhesion

    Biomet is recalling a Comprehensive Shoulder System implant component due to a defect in the porous plasma coating. The coating may not have sufficient adhesion strength, compromising the implant's structural integrity.

    Product
    Comprehensive Shoulder System Primary Shoulder Stem, Micro Length, Porous Plasma, 14 MM, 55 MM Long Item Number: 113614
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0665-2022·2022-03-02

    BD Vacutainer Luer Lok Access Device may shed particles causing false test results

    BD's Vacutainer Luer Lok Access Device may release contaminant particles that can be misidentified as red blood cells in laboratory analysis, potentially leading to false elevated RBC counts.

    Product
    BD Vacutainer Luer Lok Access Device - intended as a sterile, single use device designed to provide a connection to a catheter port equipped with a threaded female luer during blood or urine sample collection using evacuated BD Vacutainer Blood or Urine Collection Tubes Catalog…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0670-2022·2022-03-02

    Hip implant revision system recalled due to inadequate coating adhesion

    Biomet is recalling 19 units of the Arcos Modular Revision Hip System because an incorrect rework process may have weakened the coating's adhesion strength, posing a potential implant failure risk.

    Product
    Arcos Modular Revision Hip System, Standard Cone Prox Body, Porous Plasma,Size A, 60 MM Item Number: 11-301301
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0658-2022·2022-03-02

    NobelReplace dental implant components recalled for driver engagement defect

    Nobel Biocare is recalling 702 NobelReplace dental implant components due to a manufacturing defect that prevents proper driver engagement. The defect could result in aborted or delayed surgical procedures.

    Product
    NobelReplace Conical Connection RP 4.3x11.5 mm REF 36707 STERILE R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0669-2022·2022-03-02

    RESODURA Matrix Onlay Recalled Due to Unsealed Packaging

    Collagen Matrix is recalling RESODURA matrix onlay dural substitutes due to outer packaging that is not properly sealed, potentially compromising sterility and creating a risk of infection.

    Product
    RESODURA matrix onlay 10.0 cm x 12.5 cm - indicated as dural substitutes for the repair of dura matter. REF: DUMO10125
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0676-2022·2022-03-02

    Biomet Shoulder Implant Stem Recalled for Coating Adhesion Defect

    Biomet recalls 9 Comprehensive Shoulder System Mini Humeral Stems due to potential coating adhesion defects. An incorrect rework process may have compromised the porous plasma coating adhesion strength.

    Product
    Comprehensive Shoulder System Mini Humeral Stem, Porous Plasma, 13 MM, 83 MM Long Item Number: 113633
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0671-2022·2022-03-02

    Shoulder Implant Stem Coating Defect Due to Invalid Rework Process

    Biomet is recalling a shoulder implant stem due to a manufacturing defect in the porous plasma coating. Internal testing indicated the coating may not have sufficient adhesion strength after an unvalidated waterjet rework process.

    Product
    Comprehensive Shoulder System Primary Shoulder Stem, Micro Length, Porous Plasma, 11 MM, 55 MM Long Item Number: 113611
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0661-2022·2022-03-02

    Video Camera Ceiling Tile Kits May Fall in Some Installations

    Natus Neurology is recalling IPELA FHD PTZ tile kits that may not fit properly in thinner ceiling tile grids and could suddenly fall, creating a safety hazard.

    Product
    IPELA FHD PTZ TILE KITS with Axis cameras used in combination with Natus Neuroworks/Sleepworks software
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0677-2022·2022-03-02

    Shoulder Implant Stem Recalled for Defective Coating Adhesion

    Biomet is recalling Comprehensive Shoulder System Mini Humeral Stems due to defective porous plasma coating adhesion. Internal testing indicated affected parts may lack sufficient coating strength.

    Product
    Comprehensive Shoulder System Mini Humeral Stem, Porous Plasma, 15 MM, 83 MM Long Item Number: 113635
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0668-2022·2022-03-02

    Collagen Dura Substitute Membrane Recalled for Compromised Sterility

    Collagen Matrix is recalling 68 units of DuraMatrix-Onlay Collagen Dura Substitute Membrane due to unsealed outer packaging that may compromise product sterility and increase infection risk.

    Product
    DuraMatrix-Onlay Collagen Dura Substitute Membrane 4 inches x 5 inches (10.0cm x 12.5cm) REF: CDSLM45
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0673-2022·2022-03-02

    Biomet Shoulder Stem Implants Recalled for Coating Adhesion Defect

    Biomet is recalling certain shoulder stem implants due to potential insufficient adhesion strength in the porous plasma coating. An improper rework process may have compromised the coating's integrity.

    Product
    Comprehensive Shoulder System Primary Shoulder Stem, Micro Length, Porous Plasma, 18 MM, 55 MM Long Item Number: 113618
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0660-2022·2022-03-02

    Optima Coil System Recalled for Labeling and Packaging Mix-Up

    BALT USA recalls Optima Coil System embolization devices due to labeling/pouch mix-up that could result in incorrect device selection during surgical procedures. Potential harms include vessel damage and aneurysm rupture.

    Product
    The Optima Coil System consists of an implantable embolization coil comprised of a platinum-tungsten alloy attached to a proximal stainless steel hypo-tube and distal body coil delivery pusher with a radiopaque distal positioning marker and proximal fluorosafe marker. The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0667-2022·2022-03-02

    Bard Surestep Intermittent Catheter Tray Recalled for Connection Leaks

    C.R. Bard Inc recalled 1,620 units of Bard Surestep Intermittent Catheter Tray because the catheter may leak where it connects to the drain bag. No injuries have been reported.

    Product
    BARD SURESTEP INTERMITTENT CATHETER TRAY, 14Fr, REF INTS16C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0674-2022·2022-03-02

    Comprehensive Shoulder System Mini Humeral Stem Recalled for Coating Adhesion Defect

    Biomet recalls 11 units of its Comprehensive Shoulder System Mini Humeral Stem due to potential coating adhesion defects. An unvalidated rework process was applied to vendor-coated parts, risking implant failure.

    Product
    Comprehensive Shoulder System Mini Humeral Stem, Porous Plasma, 11 MM, 83 MM Long Item Number: 113631
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0666-2022·2022-03-02

    Bard SureStep Intermittent Catheter Tray recalled for potential leak defect

    C.R. Bard is recalling 2,120 units of the BARD SURESTEP INTERMITTENT CATHETER TRAY (14Fr) due to a potential leak at the catheter-to-drain-bag connection.

    Product
    BARD SURESTEP INTERMITTENT CATHETER TRAY, 14Fr, REF INTS14C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0740-2022·2022-03-02

    EpiGenius Kids Chocolate Superfood Recalled for Undeclared Milk

    Organic By Nature, Inc. is recalling Purim Health Brands EpiGenius Kids Chocolate: Daily Superfood pouches due to undeclared milk in an MCT powder ingredient. The product poses a risk to consumers with milk allergies.

    Product
    Purim Health Brands EpiGenius Kids Chocolate: Daily Superfood 630 g pouches Suggested Use: Mix approximately three tablespoons with 8-10 ounces of cold water. Shake vigorously or blend. For a creamier texture, mix with your favorite non-diary milk or in smoothie. This delicious…
    Category
    Food
    Distribution
    0 states
  • HighFDA (Devices)·Z-0657-2022·2022-03-02

    Medtronic Endurant Stent Graft Systems: Taper Tip Detachment Risk

    Certain Medtronic Endurant stent graft systems may have taper tips that detach from the delivery system during implant procedures, potentially requiring secondary surgical intervention.

    Product
    Endurant, Endurant II and Endurant IIs Stent Graft System: Medtronic Endurant Stent Graft System Model/REF ENBF2313C120EE; ENBF2313C120EE; ENBF2313C145EE; ENBF2313C170EE; ENBF2316C120EE; ENBF2316C145EE; ENBF2316C170EE; ENBF2513C120EE; ENBF2513C145EE; ENBF2513C170EE…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0664-2022·2022-03-02

    Stryker Color Cuff tourniquet cuff mislabeled as single-bladder when dual-bladder

    Stryker Sustainability Solutions is recalling 40 units of Color Cuff 18" tourniquet cuffs (Lot #12983349) because they are mislabeled as single-bladder when they are actually dual-bladder, creating a risk of incorrect clinical use.

    Product
    REF: 5921-018-135, Stryker Color Cuff, 18" (Red), Quick Connect Single Port, Single Bladder
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0675-2022·2022-03-02

    Biomet Shoulder Implant Stem Coating Adhesion Defect Recall

    Biomet is recalling shoulder implant stems due to improper rework of porous plasma coating, which may lack sufficient adhesion strength. Affected units may fail if the coating detaches.

    Product
    Comprehensive Shoulder System Mini Humeral Stem, Porous Plasma, 12 MM, 83 MM Long Item Number: 113632
    Category
    Medical Device
    Distribution
    Distributed nationwide