The Recall Desk

State

Wyoming product recalls

72,940 recalls have nationwide distribution and so reach Wyoming. 3,219 additional recalls listed Wyoming specifically in their distribution scope.

What the numbers show

Total
3,219
Critical
762
Severe
543
Most recent
2026-09-02

Of the 3,219 recalls naming Wyoming we have scored against our rubric, 762 (24%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 543 (17%) are Severe.

These figures cover only the 3,219 recalls whose distribution notice names Wyoming specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

3326–3350 of 76159

  • ModerateFDA (Devices)·Z-1226-2026·2026-02-11

    Oxiris sets recalled over a deaeration chamber that may dislodge

    Vantive US Healthcare is recalling 2,724 Oxiris Sets because the Prismaflex Set deaeration chamber may dislodge from the Prismaflex Control Unit.

    Product
    OXIRIS SET, Product Code 112016; Dialyzer, High Permeability With Or Without Sealed Dialysate System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1294-2026·2026-02-11

    Triple lumen sphincterotomes recalled over a skipped thermoforming step

    Olympus is recalling the Disposable Triple Lumen Sphincterotome, model KD-401Q-0725, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Disposable Triple Lumen Sphincterotome Model/Catalog Number: KD-401Q-0725 Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·H-0442-2026·2026-02-11

    Collagen supplement recalled over manganese below the labeled quantity

    Optiwize is recalling 78 units of OptiWize Collagen Plus, 320 count, after NSF testing showed the manganese level was below the label quantity.

    Product
    OptiWize Health OptiWize Collagen Plus 320 count bottle; White bottle with black lid.
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1227-2026·2026-02-11

    Prismaflex M100 sets recalled over a deaeration chamber that may dislodge

    Vantive US Healthcare is recalling 230,596 Prismaflex M100 Sets because the Prismaflex Set deaeration chamber may dislodge from the Prismaflex Control Unit.

    Product
    PRIMSAFLEX M100 SET, Product Code 106697; Dialyzer, High Permeability With Or Without Sealed Dialysate System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1276-2026·2026-02-11

    Sphincterotome KD-V431M-0730 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V, model KD-V431M-0730, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V Model/Catalog Number: KD-V431M-0730; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1282-2026·2026-02-11

    Sphincterotome KD-VC412Q-0215 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V (Distal Wire guided), model KD-VC412Q-0215, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V (Distal Wire guided) Model/Catalog Number: KD-VC412Q-0215; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1275-2026·2026-02-11

    Sphincterotome KD-V431M-0720 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V, model KD-V431M-0720, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V Model/Catalog Number: KD-V431M-0720; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1240-2026·2026-02-11

    NAEOTOM Alpha software applications recalled because they lack FDA clearance

    Siemens is removing three software applications from 88 NAEOTOM Alpha CT systems because the applications have not received FDA 510(k) clearance.

    Product
    NAEOTOM Alpha Software applications: syngo.CT Brain Quantification syngo.CT Vessel Hyperdensities syngo.CT ASPECTS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1288-2026·2026-02-11

    Sphincterotome KD-401Q-0720 recalled over a skipped thermoforming step

    Olympus is recalling the Disposable Triple Lumen Sphincterotome, model KD-401Q-0720, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Disposable Triple Lumen Sphincterotome Model/Catalog Number: KD-401Q-0720 Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1277-2026·2026-02-11

    Sphincterotome KD-VC431Q-0730 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V (Distal Wire guided), model KD-VC431Q-0730, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V (Distal Wire guided) Model/Catalog Number: KD-VC431Q-0730; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1242-2026·2026-02-11

    NAEOTOM Alpha.Pro software applications recalled over missing FDA clearance

    Siemens is removing three software applications from two NAEOTOM Alpha.Pro CT systems because the applications have not received FDA 510(k) clearance.

    Product
    NAEOTOM Alpha.Pro Software applications: syngo.CT Brain Quantification syngo.CT Vessel Hyperdensities syngo.CT ASPECTS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1270-2026·2026-02-11

    Sphincterotome KD-431Q-0720 recalled over a skipped thermoforming step

    Olympus is recalling the Disposable Triple Lumen Sphincterotome, model KD-431Q-0720, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Disposable Triple Lumen Sphincterotome Model/Catalog Number: KD-431Q-0720 Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1221-2026·2026-02-11

    Hematology diluents recalled over elevated platelet background check counts

    Beckman Coulter is recalling 76,098 units of COULTER DxH Diluent and DxH ECO Diluent because specific lots contribute to elevated platelet Daily Checks background counts.

    Product
    COULTER DxH Diluent, REF 628017 COULTER DxH ECO Diluent REF C67250 For use as an isotonic buffered diluent in conjunction with a cyanide-free lytic agent for counting and sizing blood cells on all UniCel DxH Coulter Cellular Analysis Systems. For use as a rinsing agent on the
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1268-2026·2026-02-11

    CleverCut sphincterotomes recalled over a skipped thermoforming step

    Olympus is recalling the CleverCut Single Use 3-Lumen Sphincterotome V, model KD-V411M-0320, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Brand Name: CleverCut Product Name: Single Use 3-Lumen Sphincterotome V Model/Catalog Number: KD-V411M-0320; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1269-2026·2026-02-11

    Sphincterotome KD-VC431Q-0720 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use Sphincterotome V (Distal Wire guided), model KD-VC431Q-0720, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use Sphincterotome V (Distal Wire guided) Model/Catalog Number: KD-VC431Q-0720 Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1231-2026·2026-02-11

    Prismaflex TPE2000 sets recalled over a deaeration chamber that may dislodge

    Vantive US Healthcare is recalling 13,760 units of the PRISMAFLEX TPE2000 SET because the Prismaflex Set deaeration chamber may dislodge from the Prismaflex Control Unit.

    Product
    PRISMAFLEX TPE2000 SET, Product Code 114093; Dialyzer, High Permeability With Or Without Sealed Dialysate System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1285-2026·2026-02-11

    Sphincterotome KD-411Q-0720 recalled over a skipped thermoforming step

    Olympus is recalling the Disposable Triple Lumen Sphincterotome, model KD-411Q-0720, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Disposable Triple Lumen Sphincterotome Model/Catalog Number: KD-411Q-0720 Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1281-2026·2026-02-11

    Sphincterotome KD-VC411Q-0330 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V (Distal Wire guided), model KD-VC411Q-0330, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V (Distal Wire guided) Model/Catalog Number: KD-VC411Q-0330; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·H-0441-2026·2026-02-11

    Energy drink recalled over a label understating its caffeine content

    Fazt & Loud is recalling Lost and Found Energy, Sour Gummy Bear, because a label misprint states 150mg of caffeine when the product contains 300mg.

    Product
    Lost and Found Energy, Sour Gummy Bear, 12pck, 16oz Cans Case UPC: 850075595655 Can UPC: 850075595662 Aluminum Can Packaged
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1280-2026·2026-02-11

    Sphincterotome KD-VC411Q-0320 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V (Distal Wire guided), model KD-VC411Q-0320, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V (Distal Wire guided) Model/Catalog Number: KD-VC411Q-0320; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1228-2026·2026-02-11

    Prismaflex M150 sets recalled over a deaeration chamber that may dislodge

    Vantive US Healthcare is recalling 137,576 units of the PRISMAFLEX M150 SET because the Prismaflex Set deaeration chamber may dislodge from the Prismaflex Control Unit.

    Product
    PRISMAFLEX M150 SET, Product Code 109990; Dialyzer, High Permeability With Or Without Sealed Dialysate System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1254-2026·2026-02-11

    Illuminated depressors recalled with no reason given in the record

    Vortex Surgical is recalling the TID Pharos Illuminated Depressor, VS0801B. The reason field in the enforcement record reads only "XXX", so no hazard is stated.

    Product
    Vortex Surgical TID Pharos Illuminated Depressor, VS0801B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1295-2026·2026-02-11

    Sphincterotome KD-V411M-3020 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V, model KD-V411M-3020, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V Model/Catalog Number: KD-V411M-3020 Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1274-2026·2026-02-11

    Sphincterotome KD-V411M-0730 recalled over a skipped thermoforming step

    Olympus is recalling the Single Use 3-Lumen Sphincterotome V, model KD-V411M-0730, because devices which did not undergo thermoforming could deform and lose performance.

    Product
    Product Name: Single Use 3-Lumen Sphincterotome V Model/Catalog Number: KD-V411M-0730; Software Version: N/A Product Description: These instruments have been designed to be used with an Olympus endoscope and guidewire for papillotomy using high-frequency current.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1225-2026·2026-02-11

    Prismaflex ST150 sets recalled over a deaeration chamber that may dislodge

    Vantive US Healthcare is recalling 264,040 units of the PRISMAFLEX ST150 SET US because the Prismaflex Set deaeration chamber may dislodge from the Prismaflex Control Unit.

    Product
    PRISMAFLEX ST150 SET US, Product Code 107640US; Dialyzer, High Permeability With Or Without Sealed Dialysate System
    Category
    Medical Device
    Distribution
    Distributed nationwide