The Recall Desk

State

Vermont product recalls

72,940 recalls have nationwide distribution and so reach Vermont. 1,983 additional recalls listed Vermont specifically in their distribution scope.

What the numbers show

Total
1,983
Critical
199
Severe
409
Most recent
2026-09-02

Of the 1,983 recalls naming Vermont we have scored against our rubric, 199 (10%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 409 (21%) are Severe.

These figures cover only the 1,983 recalls whose distribution notice names Vermont specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

5401–5425 of 74923

  • HighFDA (Devices)·Z-2341-2025·2025-09-03

    OEC 9800 C-arm systems recalled over missing collimator cover lead tape

    GE HealthCare OEC 9800 C-arm systems are recalled because impacted units are missing the full layer of lead tape in the collimator covers, slightly increasing radiation exposure.

    Product
    GE HealthCare OEC 9800.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0604-2025·2025-09-03

    Good Neighbor alcohol prep pads recalled for alcohol below labeled concentration

    Good Neighbor Pharmacy Alcohol Prep Pads, distributed by AmerisourceBergen, are recalled nationwide because isopropyl alcohol levels fall below the labeled concentration. 66,000 pads are affected.

    Product
    GOOD NEIGHBOR PHARMACY ALCOHOL ANTISEPTIC SKIN CLEANSER — GOOD NEIGHBOR PHARMACY ALCOHOL ANTISEPTIC SKIN CLEANSER (ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighNHTSA·25V572000·2025-09-03

    Ford Recalls Vehicles Due to Rearview Camera Display Issues

    Ford is recalling specific 2015-2019 vehicles because the rearview camera may display a distorted, inverted, or blank image, increasing crash risk.

    Product
    FORD — FORD, LINCOLN F-250 SD, F-450 SD, MUSTANG, EDGE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0603-2025·2025-09-03

    H-E-B alcohol pads recalled for isopropyl alcohol below labeled concentration

    H-E-B inControl Sterile Alcohol Pads, 100 per container, are recalled nationwide because isopropyl alcohol levels fall below the labeled concentration. The recall covers 300,000 pads.

    Product
    INCONTROL ALCOHOL — INCONTROL ALCOHOL (ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0599-2025·2025-09-03

    Lisdexamfetamine 40 mg bottles recalled after being filled with 30 mg capsules

    Lisdexamfetamine Dimesylate Capsules 40 mg, lot 25280726A, distributed by Lannett, are recalled because a bottle labeled 40 mg contained 30 mg capsules. 8,544 bottles are affected.

    Product
    LISDEXAMFETAMINE DIMESYLATE — LISDEXAMFETAMINE DIMESYLATE (LISDEXAMFETAMINE DIMESYLATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0598-2025·2025-09-03

    Sucralfate tablets recalled after bankruptcy left quality program unmonitored

    Sucralfate Tablets USP 1 gram from American Health Packaging are recalled because the firm's Chapter 11 filing left it unable to monitor its quality program. 26,992 blister packs are affected.

    Product
    Sucralfate Tablets, USP 1 gram, 100 Tablets, (10x10), Rx Only, Distributed by: American Health Packaging, Columbus, Ohio 43217 NDC 60687-695-01 - Carton NDC [60687-695-11- Unit Dose]
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2442-2025·2025-09-03

    Dragonfly Essentials loupe kits recalled because nickel nose pads may cause allergy

    Orascoptic Dragonfly Essentials Kits are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 32 kits are affected.

    Product
    Orascoptic Superior Visualization Dragonfly Essentials Kit ( Nose pad, a screw, lens cleaning wipe, side shields, head strap, and a screwdriver)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2452-2025·2025-09-03

    Surgery trays recalled because they contain recalled tourniquet cuffs

    Medline General Surgery Trays are recalled because they contain recalled Stryker Color Cuff tourniquet cuffs whose flange may detach, compromising air pressure and risking tourniquet failure. 1,145 units are affected.

    Product
    The Medline General Surgery Tray is customized to meet requirements of the hospitals and health care professionals utilizing them. The kit is provided sterile, single-use and includes a range of components dependent upon the specific procedure. These kits will be assembled using
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25E054000·2025-09-03

    Magna Recalls Rearview Cameras on Ford and Chrysler Vehicles

    Magna International is recalling rearview cameras installed on certain Ford and Chrysler vehicles because they may display a blank or inverted image, increasing crash risk.

    Product
    BACK OVER PREVENTION: SENSING SYSTEM: CAMERA recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2440-2025·2025-09-03

    Custom loupes with Dragonfly frames recalled over nickel nose pad allergy risk

    Orascoptic custom loupes with Dragonfly frames are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 15,245 units are affected.

    Product
    Orascoptic Superior Visualization Custom loupes with Dragonfly frames
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V570000·2025-09-03

    Ducati Motorcycles Recalled for Defective Rear Wheel Axle

    Ducati is recalling certain 2018-2025 motorcycles because the rear wheel axle may lose structural integrity and break during riding, risking loss of control. Dealers will replace the axle free of charge.

    Product
    DUCATI — DUCATI STREETFIGHTER, STREETFIGHTER V2, PANIGALE V4 S, STREETFIGHTER V4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2443-2025·2025-09-03

    Phantom Essential loupe kits recalled because nickel nose pads may cause allergy

    Orascoptic Phantom Essential Kits are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 74 kits are affected.

    Product
    Orascoptic Superior Visualization Phantom Essential kit ( Nose pad, a screw, lens cleaning wipe, side shields, head strap, and a screwdriver)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2441-2025·2025-09-03

    Custom loupes with Phantom frames recalled over nickel nose pad allergy risk

    Orascoptic custom loupes configured with Phantom frames are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 10,611 units are affected.

    Product
    Orascoptic Superior Visualization Custom loupes configured with Phantom Frames
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2423-2025·2025-09-03

    Limb salvage canal filling stems recalled after unidentified substance found on devices

    ELEOS Bowed Canal Filling Stems are recalled because an unidentified substance of unknown impact was found on devices during a retrospective evaluation. 30 units are affected.

    Product
    ELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS BOWED CANAL FILLING STEMS. Canal filling stem implants.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2462-2025·2025-09-03

    Foley catheters recalled because obstructed lumen may prevent bladder drainage

    Bardex Lubri-Sil I.C. Foley catheters and related tray systems are recalled because the catheter may have an obstructed lumen, which may prevent the bladder from draining. 175,158 units are affected.

    Product
    Bardex Lubri-Sil I.C. 400-series Temperature Sensing Silver/Hydrogel Coated All-Silicone Foley Catheter 5cc Balloon, REF: 119314; SureStep Foley Tray System Lubri-Sil I.C. Complete Care, REF: A319514A; Bard Silver Lubri-Sil Foley Tray Temperature Sensing with Bard Hydrogel and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2420-2025·2025-09-03

    Operating tables recalled because interference can leave them unresponsive to controls

    Corin Operating Tables are recalled because interference, such as from high-frequency surgical equipment used at the same time, can leave the table unresponsive to both the remote control and the override panel.

    Product
    Corin Operating Tables Model Numbers: (1) 770001A0, (2) 770001A2, (3) 770001B0, (4) 770001B2, (5) 770001F0, (6) 770001F2; All Software Versions.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2425-2025·2025-09-03

    Limb salvage stem extensions recalled after unidentified substance found on devices

    ELEOS Segmental Limb Salvage System straight splined slotted stem extensions are recalled because an unidentified substance of unknown impact was found on devices during a retrospective evaluation. 554 units are affected.

    Product
    ELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS STEM EXTENSION, STRAIGHT, SPLINED, SLOTTED. Canal filling stem implants.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0600-2025·2025-09-03

    Medline alcohol prep pads recalled for alcohol below labeled concentration

    Medline Alcohol Prep Pads, 70% isopropyl alcohol, are recalled nationwide because isopropyl alcohol levels fall below the labeled concentration. The recall covers 6,669,874 swabs.

    Product
    MEDLINE ALCOHOL PREP — MEDLINE ALCOHOL PREP (ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0601-2025·2025-09-03

    CURAD alcohol prep pads recalled for isopropyl alcohol below labeled strength

    CURAD Sterile Alcohol Prep Pads, medium 2-ply, are recalled nationwide because isopropyl alcohol levels fall below the labeled concentration. The recall covers 1,639,996 pads.

    Product
    CURAD ALCOHOL PREP PADS — CURAD ALCOHOL PREP PADS (ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2445-2025·2025-09-03

    Phantom nose pad kits recalled because nickel content may cause allergic reaction

    Orascoptic Phantom Nose Pad Accessory Kits are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 22 kits are affected.

    Product
    Orascoptic Superior Visualization Phantom Nose Pad Accessory Kit ( nose pad and screw) 1 pk. and 20 pk.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2444-2025·2025-09-03

    Loupe nose pad kits recalled because nickel content may cause allergic reaction

    Orascoptic Dragonfly Nose Pad Accessory Kits are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 743 kits are affected.

    Product
    Orascoptic Superior Visualization Dragonfly Nose Pad Accessory Kit ( nose pad and screw) 1 pk and 20 pk.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2342-2025·2025-09-03

    C-arm imaging systems recalled over missing lead tape in collimator covers

    GE HealthCare OEC 9800 and OEC 9900 Elite C-arm systems are recalled because impacted units are missing the full layer of lead tape in the collimator covers, slightly increasing radiation exposure.

    Product
    GE HealthCare OEC 9900 Elite C-arm Systems.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2424-2025·2025-09-03

    Canal filling stems recalled after unidentified substance found during retrospective evaluation

    ELEOS Segmental Stem Canal Filling straight slotted splined 2/3 plasma implants are recalled because an unidentified substance of unknown impact was found on devices. 15 units are affected.

    Product
    ELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS SEGMENTAL STEM CANAL FILLING STRAIGHT SLOTTED SPLINED 2/3 PLASMA. Canal filling stem implants.
    Category
    Medical Device
    Distribution
    Distributed nationwide