  • HighFDA (Devices)·Z-0721-2024·2024-01-24

    Curaplex Cricothyrotomy Field Kit Recalled for Incompatible Tube Holder

    Sarnova HC recalls 15 Curaplex Cricothyrotomy Field Kits nationwide due to an incompatible endotracheal tube holder that prevents proper tube securement during cricothyrotomy procedures.

    Product
    Curaplex Cricothyrotomy Field Kit with Instruments, Kwik Cric MVP, 6.0mm, Item Number 351631i-A. The kit provides healthcare professionals with an assortment of supplies to perform a cricothyrotomy.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0727-2024·2024-01-24

    Organic Chicken Broth Recalled for Potential Microbial Contamination

    TreeHouse Foods is recalling Organic Low/Reduced Sodium Chicken Broth sold under multiple brands due to potential microbial contamination. The recall affects 439,240 cases distributed across 37 states.

    Product
    Organic Low/Reduced Sodium Chicken Broth sold under: O Organics 32oz Organic Low Sodium Chicken Broth Central Market, 32oz Organic Low Sodium Chicken Broth Lidl, 32oz Organic Low Sodium Chicken Broth
    Category
    Food
    Distribution
    37 states
  • HighFDA (Devices)·Z-0751-2024·2024-01-24

    Medical Device Calibration Serums Recalled Due to Instructional Transcription Errors

    Randox Laboratories has recalled multiple calibration serum products due to transcription errors in the Instructions for Use, which contain incorrect target values for several analytes.

    Product
    Calibration Serum Level 3. CAL 3, REF CAL2351. Human Assayed Multi-Sera Level 2 (HN1530) Human Assayed Multi-Sera Level 3 (HE 1532)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0247-2024·2024-01-24

    Secret OUTLAST Dry Spray Antiperspirant recalled for potential benzene contamination

    Procter & Gamble is recalling Secret OUTLAST Dry Spray Antiperspirant due to a manufacturing facility deviation where other lots were found contaminated with benzene. The recalled product was manufactured at the affected facility.

    Product
    Secret, OUTLAST, Dry Spray, (Aluminum chlorohydrate 23.5%), Antiperspirant, Completely Clean, Topical spray can 3.8 oz (107 g), Dist. by: Procter & Gamble, Cincinnati, OH 45202. NDC: 69423-384-10, UPC 0 37000 74764 2
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0741-2024·2024-01-24

    FDA Recalls Medical Pressure Tubing With Defective O-Ring Seals

    Smiths Medical is recalling 31,685 units of pressure tubing with defective O-rings that may not seal properly during medication infusion, potentially causing medication leaks and underdosing. The defect affects specific lot numbers with worldwide distribution.

    Product
    6IN PRESSURE TUBING, List Number MX20617
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0730-2024·2024-01-24

    Ultrasound Examination Table Recalled for Backrest Stress Fracture

    Oakworks Inc is recalling 28 Ultrasound EA examination tables due to backrest platform stress fractures that prevent operation in an inclined position.

    Product
    Ultrasound EA (Ergonomic Advantage) table version; V2 (Vascular 2 Section) Echocardiography -An Ultrasound examination table
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0770-2024·2024-01-24

    Maquet Blueline Series OR Light Systems Recalled Due to Fall Risk

    Getinge Usa Sales Inc is recalling Maquet Blueline Series 30/80 operating room light systems that may fall in the operating room. No injuries have been reported.

    Product
    Maquet Blueline Series 30/80 OR Light Systems, Model Numbers and Catalog Numbers BLUE 30 - ARD569015111A, BLUE 30 - ARD569015111C, BLUE 30 - ARD569015131C, BLUE 30 - ARD569025111C, BLUE 30 - ARD569025131C, BLUE 30 - ARD569035111C, BLUE 30 - ARD569035131C, BLUE 30…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0746-2024·2024-01-24

    Medex Injection Line Rotating Adapter Recalled Due to O-Ring Defect

    Smiths Medical is recalling Medex injection line rotating adapters due to a manufacturing defect where the O-ring inner diameter may be oversized, potentially causing medication leaks during infusion.

    Product
    Medex 20IN (50.8CM) INJ LINE ROTATING ADAPT, List Number MX682R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0731-2024·2024-01-24

    Philips Patient Information Center iX: Push Notifications May Fail to Send

    Philips Patient Information Center iX devices may fail to send push notifications under certain conditions, potentially delaying detection of patient condition changes. A total of 814 units have been recalled worldwide.

    Product
    (1) Patient Information Center iX, Model No. 866389 (2) Patient Information Center iX Expand, Model No. 866390 (3) PIC iX Hardware, Model No. 866424
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0749-2024·2024-01-24

    Link Patella Glide Resection Guide recalled due to size mislabeling

    A surgical guide used in knee replacement is recalled due to mislabeling showing incorrect dimensions. This could result in improper bone resection and implant fit, potentially extending surgery time.

    Product
    Link Patella Glide Resection Guide- For the implantation of the Endo-Model Knee System as part of a total knee arthroplasty procedure. Product Code: 15-2530/05
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0727-2024·2024-01-24

    Ultrasound examination table recalled due to backrest platform stress fracture

    Oakworks Inc is recalling 212 Ultrasound EA G2 examination tables nationwide due to stress fractures in the backrest platform that make the equipment non-operational in an inclined position.

    Product
    Ultrasound EA (Ergonomic Advantage) table versions; G2 (GENERAL 2) -An Ultrasound examination table
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0251-2024·2024-01-24

    Old Spice Anti-Perspirant Spray Recalled for Potential Benzene Contamination

    The FDA has recalled Old Spice SWEAT DEFENSE PURE SPORT PLUS anti-perspirant spray due to potential benzene contamination found at the manufacturing facility. All lots through September 2023 are affected.

    Product
    Old Spice, SWEAT DEFENSE PURE SPORT PLUS, (Aluminum Chlorohydrate 23.5%), Anti-Perspirant, Topical spray can, Net WT 3.8 oz (107 g) cans, Distr. by: Procter & Gamble, Cincinnati, OH 45202. NDC: 69423-387-10, UPC 0 37000 72974 7
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0733-2024·2024-01-24

    VACUETTE Blood Collection Tubes Missing Critical Anticoagulant Additive

    VACUETTE blood collection tubes are missing an anticoagulant additive, causing samples to clot and producing inaccurate or absent lab results. This can delay diagnosis or lead to inappropriate treatment.

    Product
    VACUETTE TUBE 4 ml FX Sodium Fluoride/Potassium Oxalate, Item #454297, 13x75 grey cap-black ring, non-ridged.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0767-2024·2024-01-24

    Maquet Prismalix OR Light Systems recalled due to fall hazard

    Getinge has recalled 236,793 Maquet Prismalix operating room light systems because the systems could potentially fall. The recall affects units distributed nationwide in the U.S. and globally.

    Product
    Maquet Prismalix OR Light Systems, Model Numbers and Catalog Numbers 3001 - ARD567424001C, 3001 HMS07 - ARD567722001C, 3001 HXS12 - ARD567703001C, 4001 S/DF - ARD567211211C, 4001 SAD/DF - ARD567221211C, 4001 SAD/DF - ARD567221241C, 4001 SAD/SF - ARD567221141C, 4001 SAI/DF…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0232-2024·2024-01-24

    FDA Recalls Vasostrict Injection for Exceeding Potency Specifications

    Par Sterile Products recalled Vasostrict (vasopressin) injection because stability testing showed the drug exceeded its upper potency specification limit. The recall involves 1,721 cartons distributed nationwide.

    Product
    VASOSTRICT — VASOSTRICT (VASOPRESSIN)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0739-2024·2024-01-24

    Medex LOGICAL CATH LAB KIT Recalled for Oversized O-Ring Defect

    Smiths Medical is recalling the Medex LOGICAL CATH LAB KIT due to a manufacturing defect where the O-ring inner diameter may be oversized, affecting seal integrity and potentially leading to medication under-infusion.

    Product
    Medex LOGICAL CATH LAB KIT, List Number M20754
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0728-2024·2024-01-24

    Ultrasound Examination Table Recall Due to Backrest Platform Stress Fracture

    Oakworks Inc is recalling Ultrasound EA examination tables because the backrest platform can develop stress fractures, making the table inoperable in inclined positions. Approximately 104 units distributed nationwide are affected.

    Product
    Ultrasound EA (Ergonomic Advantage) table versions; G3 (General 3 Section) Echocardiography -An Ultrasound examination table
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0734-2024·2024-01-24

    FreeStyle Libre 3 App may lose signal on Android 13 devices

    Abbott is recalling FreeStyle Libre 3 App on Android 13 devices due to signal loss that may prevent users from receiving glucose readings and alarms, potentially delaying necessary treatment.

    Product
    FreeStyle Libre 3 App, part of Continuous Glucose Monitoring System, when used on the Android 13 Operating System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0250-2024·2024-01-24

    Old Spice Pure Sport Deodorant Spray Recalled for Benzene Contamination Risk

    Procter & Gamble is recalling Old Spice Pure Sport Anti-Perspirant & Deodorant Spray (6.0 oz) due to potential benzene contamination risk from manufacturing facility CGMP deviations. All affected lots expire through September 2023.

    Product
    Old Spice, PURE SPORT, (Aluminum Chlorohydrate 23.5%), Anti-Perspirant & Deodorant Spray, Topical spray can, Net WT 6.0 OZ (170g), Distributed by Procter & Gamble, Cincinnati, OH 45202. NDC: 37000-199-60, UPC 0 12044 00191 2
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0745-2024·2024-01-24

    Braided Injection Line Recalled for Potential Medication Leaks

    Smiths Medical is recalling approximately 31,685 units of a braided injection line due to manufacturing defects in the O-ring seal. The defect may cause medication leaks that reduce drug delivery.

    Product
    20IN (50.8CM) BRAIDED INJ LINE, ROTATING ADAPT, List Number MX682BR
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0738-2024·2024-01-24

    COVID-19 Rapid Antigen Test Recalled for Incorrect Expiration Date Labeling

    INDICAID COVID-19 Rapid Antigen At-Home Tests were released with an incorrect expiration date (05 April 2024) instead of the correct date (21 February 2024). Expired tests may produce inaccurate or invalid results.

    Product
    INDICAID COVID-19 Rapid Antigen At-Home Test, REF: P0040
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0742-2024·2024-01-24

    Medex 700PSI Stopcock with Rotator Recalled Due to Seal Defect

    Smiths Medical is recalling Medex 700PSI stopcocks with rotators due to a manufacturing defect affecting the O-ring seal. The defect may cause medication leakage and under-infusion during patient treatment.

    Product
    Medex 700PSI STOPCOCK W/ROTATOR, List Number MX4331R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0761-2024·2024-01-24

    Maquet Operating Room Light Systems Recalled Due to Fall Risk

    Getinge USA Sales Inc is recalling Maquet Equipment OR Light Systems due to a potential risk that the light systems could fall in the operating room. Approximately 236,793 units have been distributed.

    Product
    Maquet Equipment OR Light Systems, Model Numbers and Catalog Numbers BRAINLAB CAMERA - ARDEQT269000A, BRAINLAB CAMERA - ARDEQT269000C, BRAINLAB CAMERA - ARDEQT269001A, BRAINLAB CAMERA - ARDEQT269001C, BRAINLAB CAMERA - ARDEQT269004A, BRAINLAB CAMERA - ARDEQT269004C, BRAINLAB…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0768-2024·2024-01-24

    Maquet Hanaulux HLX2000 Operating Room Lights Recalled Due to Fall Hazard

    Getinge Usa Sales Inc is recalling Maquet Hanaulux HLX2000 OR Light Systems because the light fixture may fall from its mounting in the operating room. Nearly 237,000 units are affected.

    Product
    Maquet Hanaulux HLX2000 OR Light Systems, Model Numbers and Catalog Numbers 3001 - ARD567424001C, 3001 HMS07 - ARD567722001C, 3001 HXS12 - ARD567703001C, 4001 S/DF - ARD567211211C, 4001 SAD/DF - ARD567221211C, 4001 SAD/DF - ARD567221241C, 4001 SAD/SF - ARD567221141C, 4001 SAI/DF…
    Category
    Medical Device
    Distribution