  • HighFDA (Devices)·Z-3201-2024·2024-10-02

    Philips MR 5300 MRI System Recalled for Loose Assembly Screws

    Philips is recalling 68 MR 5300 MRI diagnostic systems worldwide because loose screws in the RF carrier assembly could block equipment movement and delay patient diagnosis.

    Product
    MR 5300 - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3275-2024·2024-10-02

    Boston Scientific Esophageal Stents Recalled for Catheter Tip Detachment Risk

    Boston Scientific is recalling WallFlex and Agile Esophageal Stent Systems due to potential delivery catheter tip detachment. The recall affects 231 units distributed worldwide.

    Product
    WALLFLEX ESOPHAGEAL FC 18/23-25MMX10CM- Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent e
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3197-2024·2024-10-02

    MRI Device Ingenia Ambition S Screws May Loosen and Block Tabletop

    Assembly screws in Philips Ingenia Ambition S MRI systems may loosen and protrude, potentially blocking the patient tabletop and delaying diagnosis. Philips is recalling 64 affected units worldwide.

    Product
    Ingenia Ambition S - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782108 2) 781359 3) 782133
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3213-2024·2024-10-02

    Cervical disc implant recalled due to foreign contamination during assembly

    Centinel Spine is recalling the Prodisc C SK cervical disc implant due to blue discoloration identified as foreign contamination on the inlay during assembly. The contamination was not fully evaluated in manufacturing validations.

    Product
    prodisc C SK, Total cervical disc replacement, Model/Catalog Number: PDSM5
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3245-2024·2024-10-02

    FDA Recalls Surgical Instrument Handle That May Break During Use

    The FDA is recalling LINK Universal Handles due to risk of material failure when first used. The surgical instrument may break during surgery, compromising patient safety.

    Product
    LINK Universal Handle, with quick coupling, Stainless Steel, straight, Item Number 130-394/01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3290-2024·2024-10-02

    Esophageal stent systems recalled due to delivery catheter defect

    Boston Scientific has recalled AGILE and WallFlex esophageal stent systems due to potential delivery catheter tip detachment. This defect could occur during stent deployment and affect proper stent placement.

    Product
    AGILE ESO OTW PC 23MM X 15.0CM IN 18.5 F-Agile Esophageal Partially Covered (PC) and Fully Covered (FC) OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concu
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3258-2024·2024-10-02

    Biodesign Recto-Vaginal Fistula Plug expires before labeled expiration date

    Cook Biotech is recalling 3 units of Biodesign Recto-Vaginal Fistula Plug RVP-0.2 because the devices expire prior to the expiration date printed on the labeling.

    Product
    Biodesign Recto-Vaginal Fistula Plug RVP-0.2 - For implantation to reinforce soft tissue for repair of recto-vaginal fistulas. Order Number (GPN): G46601
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3247-2024·2024-10-02

    BD Phoenix diagnostic systems may misidentify E. coli in clinical samples

    The BD Phoenix 100 system may misidentify Escherichia coli in clinical samples, potentially leading to misdiagnosis and inappropriate patient treatment. Becton Dickinson is recalling 764 units distributed worldwide.

    Product
    BD Phoenix 100-Intended for the rapid identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria. The BD Phoenix System provides rapid results for most aerobic and facultative anaerobic Grampositive bacteria. Catalog Number: 448100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3199-2024·2024-10-02

    MRI Diagnostic Device Recalled for Loose Assembly Screws Blocking Equipment

    Philips Ingenia Elition S MRI machines (10 units) are recalled because assembly screws may come loose and interfere with the horizontal tabletop, potentially delaying diagnosis and causing patient anxiety.

    Product
    Ingenia Elition S -For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782150 2) 782106
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3209-2024·2024-10-02

    Ultrasonic Cleaner Solution Recalled for Bacterial Contamination and Infection Risk

    Ultrasonic cleaner solutions contaminated with pathogenic bacteria may cause serious infections if used in medical or dental procedures, and may leak or become bloated. Patients and healthcare workers handling the products are at risk.

    Product
    Good Vibrations Ultrasonic Cleaner Solution, JorVet J0382G Ultrasonic Instrument Cleaning Solution, SpecClean Ultrasonic Cleaner Solution, Models: GVUS128-1, GVUS128-1EA, GVUS550-1, GVUS24-1, GVUS24-1EA, JGVUS128-1, VGVUSNP128-1, VGVUSNP128-1EA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3226-2024·2024-10-02

    Medical Pacemaker Pack Recalled Due to Sterilization Assurance Failure

    American Contract Systems is recalling the PACEMAKER PACK (Lot 2405112) due to an inoperable chart recorder that prevented confirmation of sterilization requirements. Affected units were distributed in MO, MN, MA, OH, and NE.

    Product
    PACEMAKER PACK, SLCV01J; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3194-2024·2024-10-02

    Philips Ingenia 1.5T MRI Device Recall: Loose Screws May Block Tabletop

    Philips recalls certain Ingenia 1.5T MRI devices due to loose assembly screws that may block the patient tabletop, potentially delaying diagnosis and causing patient anxiety.

    Product
    Ingenia 1.5T -For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782115 2) 782101 3) 782140
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3276-2024·2024-10-02

    Boston Scientific Esophageal Stents Recalled for Delivery Catheter Tip Detachment

    Boston Scientific is recalling Wallflex and Agile Esophageal Stent Systems due to potential for delivery catheter tip detachment. The recall involves 124 units distributed worldwide.

    Product
    WALLFLEX ESOPHAGEAL FC 18/23-25MMX12CM-- Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0663-2024·2024-10-02

    Pyridoxine Injection Solution Recalled Due to Lack of Sterility Assurance

    Empower Pharmacy is recalling a pyridoxine (B6) injection solution because sterility assurance could not be confirmed. The recalled product is lot 609763 with a beyond-use date of 04/18/2025.

    Product
    Pyridoxine HCL (B6) Injection Solution, 100mg/mL, 30 mL Sterile Multiple-Dose Vial, For IM or IV use only, RX Only, Compounded by: Empower Pharmacy 5980 W Sam Houston Pkwy N Ste 300, Houston, TX 77041 NDC 72627-2424-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3244-2024·2024-10-02

    Pacemaker COPM11B Medical Kits Recalled for Sterilization Verification Issue

    American Contract Systems is recalling 3 units of the COPM11B pacemaker medical kits due to inability to confirm sterilization requirements were met. An inoperable chart recorder caused humidity readings to exceed specifications during manufacturing.

    Product
    Pacemaker, COPM11B; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3238-2024·2024-10-02

    Vaginal Delivery Medical Convenience Kit Recalled for Unconfirmed Sterilization Assurance

    American Contract Systems, Inc. is recalling the Vaginal Delivery ASDV25B medical convenience kit due to an inoperable chart recorder that prevented confirmation of sterilization assurance. The device may not meet required sterilization standards.

    Product
    Vaginal Delivery, ASDV25B; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3283-2024·2024-10-02

    Wallflex and Agile Esophageal Stent Systems Recalled for Potential Catheter Tip Detachment

    Boston Scientific is recalling WallFlex and Agile Esophageal Stent Systems due to the potential for delivery catheter tip detachment. The recall affects 39 units distributed worldwide.

    Product
    WALLFLEX PC ESOPH STENT 18/23MM X 153MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3251-2024·2024-10-02

    Cook Biotech Fistula Plug recalled for expiring before labeled date

    Cook Biotech is recalling 3 units of Biodesign Fistula Plug surgical implants because they expire before the printed expiration date. The devices were distributed worldwide.

    Product
    Biodesign Fistula Plug C-FPB-0.7 - For implantation to reinforce soft tissue for repair of recto-vaginal or anorectal fistulas. Order Number (GPN): G24668
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3264-2024·2024-10-02

    Stryker TMJ Unilateral Implant Recalled Due to Incorrect Components

    TMJ Solutions Inc is recalling the Stryker TMJ Unilateral Implant because patient-fitted prostheses contained incorrect components. Patients should contact their healthcare provider immediately.

    Product
    Stryker TMJ Unilateral Implant, REF: GHG010, consisting of the following components: Ref: CHG010AM, Anatomical Bone Model, Accessory, REF: CHG010RF, Glenoid Fossa Component, Right, REF: CHG010RM, Mandibular Component, Right.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3203-2024·2024-10-02

    MRI Diagnostic Device Screws May Loosen, Block Tabletop

    Philips SmartPath to dStream 1.5T MRI devices may have loose assembly screws that could block the diagnostic tabletop and delay imaging. 32 units distributed worldwide.

    Product
    SmartPath to dStream for 1.5T - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782112; 2) 781260
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3286-2024·2024-10-02

    WallFlex and Agile esophageal stent systems recalled for delivery catheter tip detachment

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems due to potential for delivery catheter tip detachment during insertion.

    Product
    WALLFLEX PC ESOPH STENT 23/28MM X 155MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3259-2024·2024-10-02

    Biodesign Recto-Vaginal Fistula Plug units expire before labeled date

    Cook Biotech recalls Biodesign Recto-Vaginal Fistula Plug RVP-0.4 units because they expire before their labeled expiration dates. Affected lots were distributed worldwide.

    Product
    Biodesign Recto-Vaginal Fistula Plug RVP-0.4 - For implantation to reinforce soft tissue for repair of recto-vaginal fistulas. Order Number (GPN): G46602
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3273-2024·2024-10-02

    Wallflex and Agile Esophageal Stent Systems Recalled Due to Catheter Tip Detachment Risk

    Boston Scientific is recalling the Wallflex Esophageal Stent System and Agile Esophageal Over the Wire Stent System due to potential delivery catheter tip detachment during placement. Wallflex devices totaling 115 units are affected.

    Product
    WALLFLEX FC ESO STENT RMV LL 23X125-Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esoph
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3246-2024·2024-10-02

    BD Phoenix M50 may misidentify E. coli bacteria in clinical samples

    The BD Phoenix M50 instruments may misidentify Escherichia coli (E. coli) in clinical samples, potentially causing misdiagnosis and inappropriate treatment. About 4,295 affected units were distributed worldwide.

    Product
    BD Phoenix M50 instrument -Intended for the rapid identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria. The BD Phoenix System provides rapid results for most aerobic and facultative anaerobic Grampositive bacteria. Catalog Number:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3217-2024·2024-10-02

    Siemens Diagnostic Ultrasound Systems Recalled for Incorrect Unit Conversion

    Siemens ACUSON Maple ultrasound systems may perform incorrect unit conversion in software, producing values 10 times smaller than actual. This could lead to misdiagnosis or inappropriate patient management.

    Product
    ACUSON Maple 1.0 Diagnostic Ultrasound System, REF: 11711750, with software. ACUSON Maple Select 1.0 Diagnostic Ultrasound System, REF: 11711779, with software
    Category
    Medical Device
    Distribution
    42 states