  • CriticalFDA (Devices)·Z-0825-2025·2025-01-22

    ALTRUA 2 DR Pacemaker Models S702 and S722 Safety Mode Risk

    Boston Scientific ALTRUA 2 DR Pacemakers may unexpectedly enter Safety Mode during normal operation due to high battery impedance, potentially affecting device functionality.

    Product
    ALTRUA 2 DR Pacemaker, SL (Model Number S702) and EL (Model Number S722)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0830-2025·2025-01-22

    Impella RP Flex Devices Recalled Due to Optical Sensor Damage Risk

    Abiomed is recalling 2,364 units of the Impella RP Flex with SmartAssist due to risk of optical sensor damage from device interaction. Damage may cause temporary or permanent pump stop and loss of vital monitoring signals.

    Product
    Impella RP Flex with SmartAssist; Product Number: 1000323;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0887-2025·2025-01-22

    Life2000 Ventilation System battery charger defect causes device inoperability

    Baxter Healthcare is recalling the Life2000 Ventilation System due to a battery charger defect that can trigger an alarm, rendering the ventilator inoperable and unable to support patients' breathing.

    Product
    Breathe Technologies, Inc., Life2000 Ventilation System, REF BT-20-0002AP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0884-2025·2025-01-22

    Welch Allyn Life 2000 Ventilator Battery Charger Defect Causes Inoperability

    The Welch Allyn Life 2000 Ventilator has a battery charger defect that could cause an alarm, rendering it inoperable. 187 units nationwide are affected in this FDA Class I recall.

    Product
    Welch Allyn, Inc., Life 2000 Ventilation System, REF BT-20-0002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0886-2025·2025-01-22

    Welch Allyn Life2000 Ventilator Battery Charger Malfunction Recall

    Baxter Healthcare Corporation is recalling Welch Allyn Life2000 Ventilation Systems due to a battery charger malfunction that triggers an alarm and renders the ventilator inoperable.

    Product
    Welch Allyn, Inc., Life2000 Ventilation System, REF BT-20-0002AP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0831-2025·2025-01-22

    Dialysis Blood Circuit May Cause Excessive Fluid Removal

    The AquaFlexFlow UF 500 Plus blood circuit may malfunction and remove excessive fluid from patients, causing a dangerous drop in blood volume. This risk is especially dangerous for pediatric patients.

    Product
    nuwellis AquaFlexFlow UF 500 Plus, REF 114156, Catalog Number A06163, extracorporeal blood circuit which is used with the Aquadex SmartFlow or Aquadex FlexFlow System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0765-2025·2025-01-22

    Medline Fluid Delivery Sets Recalled Due to Assembly Error

    Medline Fluid Delivery Sets were incorrectly assembled with macro drip chambers instead of required micro drip chambers. The macro chamber delivers three times more fluid per drop, creating a risk of dosing errors.

    Product
    Medline Fluid Delivery Set with Drip Chamber: 1) MTO,135,YELLOW,MICRO,SPK-MAIMONIDES, Item Number: 60130527; 2) MTO,ANGIO,DOUBLE,SPIKE,KIT,KENNEDY HLTH, Item Number: 65111341; 3) MTO,ANGIO,SINGLE,SPIKE,KIT, Item Number: 65232486; 4) MTO,ANGIO,SINGLE,SPIKE,KIT,GOOD,SAM, Item
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0885-2025·2025-01-22

    Welch Allyn Life2000 Ventilator Battery Charger May Cause Device Inoperability

    Baxter Healthcare is recalling 946 Welch Allyn Life2000 ventilators due to a battery charger defect that can trigger an alarm and render the device inoperable.

    Product
    Welch Allyn, Inc., Life2000 Ventilation System, REF BT-20-0002A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0826-2025·2025-01-22

    CRT-P Pacemakers Recalled for Potential Safety Mode Initiation Risk

    Boston Scientific's ACCOLADE Family pacemakers, including VALITUDE CRT-P models, are recalled due to battery impedance defects that could trigger unintended Safety Mode during normal operation.

    Product
    VALITUDE CRT-P, EL (Model Number U125) and EL MRI (Model Number U128)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0827-2025·2025-01-22

    VISIONIST CRT-P Pacemakers Recalled Due to Battery Impedance Risk

    Certain VISIONIST CRT-P pacemakers with latent high battery impedance may initiate Safety Mode unexpectedly during normal operations. Manufactured before September 2018, 156,329 units were distributed worldwide.

    Product
    VISIONIST CRT-P, EL (Model Number U225 and U226) and EL MRI (Model Number U228)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0829-2025·2025-01-22

    Impella RP Heart Pump Recalled Due to Optical Sensor Damage Risk

    Abiomed is recalling 1,560 units of the Impella RP with SmartAssist pump due to risk of optical sensor damage from device interactions. Damaged sensors may cause temporary or permanent pump malfunction.

    Product
    Impella RP with SmartAssist; Product Number: 0046-0035;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0822-2025·2025-01-22

    ACCOLADE DR Pacemakers Recalled for Unintended Safety Mode Activation

    Boston Scientific is recalling ACCOLADE DR Pacemakers built before September 2018 due to risk of unintended Safety Mode activation caused by battery impedance issues. The devices may enter Safety Mode during normal telemetry operations.

    Product
    ACCOLADE DR Pacemaker, SL (Model Number L301), SL MRI (Model Number L311), EL (Model Number L321), and EL MRI (Model Number L331)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0821-2025·2025-01-22

    Neo-Tee Resuscitator Spring Defect May Impair Pediatric Ventilation

    Mercury Medical is recalling the Neo-Tee T-Piece Resuscitator due to an undersized spring in the circuit flow controller that may prevent reaching proper pressure ranges, potentially impairing emergency ventilation.

    Product
    Neo-Tee T-Piece Resuscitator, for pediatric emergency respiratory support, Part: 1050805, 1050808, 1050809, 1050810, 1050811, 1050814, 1050832, 1050839, 1050840, 1050841, 1050842
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0200-2025·2025-01-22

    Systane Lubricant Eye Drops Recalled for Non-Sterility Risk

    Alcon Research is voluntarily recalling Systane Lubricant Eye Drops, Ultra PF, due to non-sterility concerns. The recall affects 55,960 boxes distributed nationwide.

    Product
    Systane Lubricant Eye Drops, Ultra PF, Sterile, 25 Vials (0.7mL Each), Manufactured for: Alcon Laboratories, Inc. Forth Worth, TX 76134
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0824-2025·2025-01-22

    ESSENTIO DR Pacemakers May Malfunction Due to Battery Impedance Issue

    Boston Scientific is recalling certain ESSENTIO DR Pacemakers manufactured before September 2018 due to latent battery impedance that may cause Safety Mode malfunction during normal operations.

    Product
    ESSENTIO DR Pacemaker, SL (Model Number L101, SL MRI (Model Number L111), EL (Model Number L121), and EL MRI (Model Number L131)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0764-2025·2025-01-22

    Medline Fluid Delivery Sets incorrectly assembled with wrong drip chamber

    Medline fluid delivery sets were assembled with a macro drip chamber instead of the required micro drip chamber, delivering three times more fluid per drop and risking patient fluid overload.

    Product
    Medline Fluid Delivery Set with Drip Chamber: 1) FDS,135,CHMN,W/F,MLL,RC(2),PG, Item Number 99000069; 2) FDS,135,NV,MICRO-CHAMBER,W/FILTER,BLUE, Item Number 949000222; 3) FDS,135,NV,MICRO-CHAMBER,W/FILTER,GREEN, Item Number 949000224; 4) FDS,135,NV,MICRO-CHAMBER,W/FILTER,RE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0905-2025·2025-01-22

    Olympus MAJ-891 Forceps Recalled for Potential Biomaterial Retention During Reprocessing

    Olympus recalls the MAJ-891 endoscope forceps/irrigation plug nationwide because improper reprocessing may leave biomaterial inside the device, creating a contamination risk.

    Product
    Olympus MAJ-891 Forceps/Irrigation Plug (Isolated Type). Model/Catalog Number: MAJ-891. This instrument is designed to be attached to the instrument channel port of Olympus endoscopes to allow both irrigation and the use of endo-therapy accessories.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0878-2025·2025-01-22

    Fenestrated Bipolar Forceps Recalled Due to Frayed or Broken Grip Cables

    Intuitive Surgical is recalling 147,006 units of 8MM Fenestrated Bipolar Forceps due to increased complaints of frayed or broken grip cables, which could impair surgical control.

    Product
    8MM,FENESTRATED BIPOLAR FORCEPS,IS4000 REF 471205
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0958-2025·2025-01-22

    Change Healthcare Cardiology Hemo software autosave defect recall

    A software defect in Change Healthcare Cardiology Hemo software may cause clinicians to administer incorrect medications. The defect affects the autosave mechanism in affected versions.

    Product
    Change Healthcare Cardiology Hemo software
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0870-2025·2025-01-22

    Intuitive Surgical Clip Applier Recalled for Frayed or Broken Grip Cables

    Intuitive Surgical is recalling 5,576 units of the 8MM Horizon Small Clip Applier due to complaints of frayed or broken grip cables on the reusable instruments.

    Product
    8MM,HORIZON SMALL CLIP APPLIER,IS4000¿ REF 470401
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0943-2025·2025-01-22

    ECONO STERILE medical procedure kits recalled for potential sterile barrier breach

    Sklar Instruments is recalling three models of ECONO STERILE medical procedure kits nationwide due to packaging issues that may breach the sterile barrier. No injuries or illnesses have been reported.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE SIMS UTERINE CURETTE #3 STER25, Model Number 96-4113; 2) ECONO STERILE KEVORK ENDO CURET W/BAS STER25, Model Number 96-4144A; 3) ECONO STERILE KEVORKIAN CURET W/O BAS STER25, Model Number 96-4145A; cervical
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0944-2025·2025-01-22

    Gynecological Speculum Kits Recalled for Potential Sterile Barrier Breach

    Sklar Instruments is recalling ECONO STERILE gynecological speculum kits due to packaging issues that may compromise sterility. No injuries have been reported.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE GRAVES SPEC STRL SM BX/25, Model Number 96-2603; 2) ECONO STERILE GRAVES SPEC STRL MD BX/25, Model Number 96-2605; 3) ECONO STERILE GRAVES SPEC STRL LG BX/25, Model Number 96-2607; 4) ECONO STERILE PEDER
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0941-2025·2025-01-22

    Sklar Instruments Sterile Surgical Kits Recalled for Packaging Defects

    Sklar Instruments is recalling 252,865 sterile surgical kits nationwide due to packaging defects that may compromise the sterile barrier, risking instrument contamination.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE IRIS SCISS 4 1/2" CVD CASE/50,Model Number 941-0918; 2) ECONO STERILE METZENBAUM SCIS STR 9"STER C25,Model Number 941-1556; 3) ECONO STERILE MAYO SCISS STRT STRL 9" CS/25,Model Number 941-1613; 4) ECONO ST
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0947-2025·2025-01-22

    ECONO STERILE Gynecologic Biopsy Kits Recalled for Sterile Packaging Issues

    Sklar Instruments is recalling ECONO STERILE gynecologic biopsy procedure kits because of packaging issues that may breach the sterile barrier.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE MINI TISCH 2.3X4.2MM STER CS10, Model Number 96-4134M; 2) ECONO STERILE OVAL BIOPSY FCP 3X7MM STER10, Model Number 96-4137M; gynecologic biopsy
    Category
    Medical Device
    Distribution
    Distributed nationwide