5401–5425 of 76011

  • HighFDA (Devices)·Z-2519-2025·2025-09-10

    Sterile cover kits recalled because elastic bands may detach during surgery

    Sterile Cover 10-Pack Shipper Box Assemblies are recalled because elastic bands in the kit may detach or fracture during surgery, risking retained foreign bodies and surgical site infection. 200 units are affected.

    Product
    Brand Name: 900-00218 Sterile Cover 10-Pack Shipper Box Assembly Product Name: 900-00218 Sterile Cover 10-Pack Shipper Box Assembly Model/Catalog Number: 900-00218 Sterile Cover 10-Pack Shipper Box Assembly Software Version: Not Applicable Product Description: Sterile Cover
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2510-2025·2025-09-10

    MediHoney hydrogel adhesive sheets recalled over sterile barrier packaging failures

    MediHoney Hydrogel Adhesive Sheet dressings, catalog numbers 31722 and 31744, are recalled after packaging failures were identified that could breach the sterile barrier. 1,147 units are affected.

    Product
    Brand Name: MediHoney¿ Product Name: MediHoney¿ Hydrogel Adhesive Sheet Model/Catalog Number: 31722, 31744 Product Description: MEDIHONEY¿ HCS ADHESIVE SHEET DRESSING with LEPTOSPERMUM HONEY is a moist wound dressing made of Leptospermum Honey (+15) in combination with a hydro
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2507-2025·2025-09-10

    MediHoney HCS sheet dressings recalled over packaging failures breaching sterility

    MediHoney HCS Sheet Dressings, catalog numbers 31612, 31622 and 31644, are recalled after packaging failures were identified that could breach the sterile barrier. 3,583 units are affected.

    Product
    Brand Name: MediHoney¿ Product Name: MediHoney¿ HCS Sheet Dressing with Leptospermum Model/Catalog Number: 31612, 31622, 31644 Product Description: MEDIHONEY¿ HCS SHEET DRESSING with LEPTOSPERMUM HONEY is a moist wound dressing made of Leptospermum Honey (+15) in combination w
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2502-2025·2025-09-10

    Azurion imaging systems recalled because single phase UPS may fail on power loss

    Philips Azurion systems configured with a 1 Phase UPS are recalled because they may shut down and/or fail to start up if power to the system is lost. 1,861 units are affected.

    Product
    Philips Azurion System configured with a 1 Phase UPS. Azurion family (R1.x, R2.x). Labeled as the following with corresponding model numbers: 1. Azurion 3 M12, Model Number 722063. 2. Azurion 3 M15, Model Number 722064. 3. Azurion 7 B12, Model Number 722067. 4. Az
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2511-2025·2025-09-10

    MediHoney surgical adhesive sheets recalled over sterile barrier packaging failures

    MediHoney HCS Surgical Adhesive Sheet dressings, catalog number 31738, lot 53824, are recalled after packaging failures were identified that could breach the sterile barrier. 4 units are affected.

    Product
    Brand Name: MediHoney¿ Product Name: MediHoney¿ HCS Surgical Adhesive Sheet Model/Catalog Number: 31738 Product Description: MEDIHONEY¿ HCS SURGICAL ADHESIVE SHEET DRESSINGS with LEPTOSPERMUM HONEY is a moist wound dressing made of Leptospermum Honey (+15) in combination with
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2509-2025·2025-09-10

    MediHoney non-adhesive hydrogel dressings recalled over sterile barrier packaging failures

    MediHoney Non-Adhesive Hydrogel Sheet Dressings, catalog numbers 31620 and 31640, are recalled after packaging failures were identified that could breach the sterile barrier. 5,374 units are affected.

    Product
    Brand Name: MediHoney¿ Product Name: MediHoney¿ Hydrogel Model/Catalog Number: 31620, 31640 Product Description: MEDIHONEY¿ Non-Adhesive Hydrogel Sheet Dressing with Leptospermum Honey is a moist wound dressing made of Leptospermum Honey (+15) in combination with a hydrogel ge
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V589000·2025-09-10

    Volvo Recalls 2026 Models Due to Damaged Front Seat Belt Retractors

    Volvo is recalling 2026 V60, V90, XC60, and XC90 models because damaged seat belt retractors may fail to restrain occupants in a crash.

    Product
    VOLVO — VOLVO V60CCMHEV, V90CCMHEV, XC60MHEV, redundant XC90MHEV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2508-2025·2025-09-10

    MediHoney hydrogel sheet dressings recalled over packaging failures compromising sterility

    MediHoney Adhesive Hydrogel Sheet Dressings, catalog numbers 31720 and 31740, are recalled after packaging failures were identified that could breach the sterile barrier. 994 units are affected.

    Product
    Brand Name: MediHoney¿ Product Name: MediHoney¿ Adhesive Hydrogel Sheet Dressing Model/Catalog Number: 31720, 31740 Product Description: MEDIHONEY¿ Adhesive Hydrogel Sheet Dressing with Leptospermum Honey is a moist wound dressing made of Leptospermum Honey (+15) in combinat
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2486-2025·2025-09-10

    Radiotherapy systems recalled over software allowing more than two daily fractions

    RefleXion X1 systems are recalled because an incorrect software configuration potentially allows more than two treatment fractions within a 12-hour period, which could lead to toxicity. 11 units are affected.

    Product
    RefleXion X1 Model RXM1000 UDI Codes: (01)00860003983812(11)230504(21)X11001 (01)00860003983812(11)230518(21)X11002 (01)00860003983812(11)230505(21)X11003 (01)00860003983812(11)230530(21)X11004 (01)00860003983812(11)230811(21)X11006 (01)00860003983812(11)230410(21)X11007
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0608-2025·2025-09-10

    Compounded semaglutide 0.8 mL vials recalled after testing subpotent

    Semaglutide 2.5 mg/mL injection, 0.8 mL, from Boothwyn Pharmacy is recalled nationwide as a subpotent drug. 186 vials are affected.

    Product
    Semaglutide, 2.5 mg/mL injection, 0.8 mL, Boothwyn Pharmacy
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2505-2025·2025-09-10

    MediHoney paste tubes 31505 recalled over packaging failures affecting sterility

    MediHoney Paste, catalog number 31505, is recalled after packaging failures were identified that could lead to a breach in the sterile barrier. 15,441 units are affected.

    Product
    Brand Name: MediHoney ¿ Product Name: MediHoney¿ Paste Model/Catalog Number: 31505 Product Description: MediHoney¿ Paste with Active Leptospermum Honey is a moist dressing made of 100% Active Leptospermum medical grade Honey. The dressing helps maintain a moist environment con
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0614-2025·2025-09-10

    KIMMTRAK injection recalled after testing subpotent in three affected lots

    KIMMTRAK (tebentafusp-tebn) Injection, 100 mcg/0.5 mL, is recalled nationwide as a subpotent drug. 7,572 vials are affected.

    Product
    KIMMTRAK (tebentafusp-tebn) Injection, 100 mcg/0.5 mL, For intravenous Infusion After Dilution, Single-Does vial. Mfd by: Immunocore Limited, 92 Park Drive, Abingdon, Oxfordshire, OX14 4RY, United Kingdom, For: Immunocore Commercial LLC, 181 Washington St, Conshohocken, PA, 19428
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2513-2025·2025-09-10

    External fixation universal joints recalled because pins may become dislodged

    Medshape Universal Joints, REF DNE-9000-UJ, are recalled because a pin in the bone external fixation system can become dislodged, causing frame instability. 849 units are affected.

    Product
    Medshape Universal Joints, REF: DNE-9000-UJ
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2485-2025·2025-09-10

    Spinal decompression implants recalled after review found instrument and device breakage

    Superion Indirect Decompression System implants and kits are recalled because a product performance review found the device and instruments are not consistently meeting expected performance, including breakage. 70,516 units are affected.

    Product
    Superion IDS Kit Superion Indirect Decompression System 8MM, VF Implant 101-9808 00884662000529 Superion Indirect Decompression System 10MM, VF Implant 101-9810 00884662000536 Superion Indirect Decompression System 12MM, VF Implant 101-9812 00884662000543 Superion
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2506-2025·2025-09-10

    MediHoney paste tubes recalled over packaging failures breaching the sterile barrier

    MediHoney Paste tubes, catalog numbers 31515 and 31535, are recalled after packaging failures were identified that could lead to a breach in the sterile barrier. 141,620 units are affected.

    Product
    Brand Name: MediHoney ¿ Product Name: MediHoney ¿ Tube Model/Catalog Number: 31515 and 31535 Product Description: MediHoney¿ Paste with Active Leptospermum Honey is a moist dressing made of 100% Active Leptospermum medical grade Honey. The dressing helps maintain a moist envir
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0617-2025·2025-09-10

    Chlorpromazine 50 mg tablets recalled over micro-organism on packaging coil

    Amneal chlorpromazine hydrochloride tablets, 50 mg, are recalled because a micro-organism was detected on a lot of auxiliary polyester coil used in packaging. No micro-organism was found on any tablets.

    Product
    CHLORPROMAZINE HYDROCHLORIDE — CHLORPROMAZINE HYDROCHLORIDE (CHLORPROMAZINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0615-2025·2025-09-10

    Sulfamethoxazole and trimethoprim tablets recalled over micro-organism on packaging coil

    Amneal sulfamethoxazole and trimethoprim double strength tablets are recalled because a micro-organism was detected on a lot of auxiliary polyester coil used in packaging. No micro-organism was found on any tablets.

    Product
    SULFAMETHOXAZOLE AND TRIMETHOPRIM — SULFAMETHOXAZOLE AND TRIMETHOPRIM (SULFAMETHOXAZOLE AND TRIMETHOPRIM)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2504-2025·2025-09-10

    Fluoroscopic X-ray systems recalled over air baffle missing from internal PCs

    Philips Allura Xper interventional fluoroscopic X-ray systems are recalled because an air baffle component may be missing in some Nehalem FlexVision-2 PCs. 192 units are affected.

    Product
    Interventional Fluoroscopic X-Ray System - Philips Allura Xper Series. Labeled as the following with corresponding model numbers: 1. Allura Xper FD10, Model Number 722003. 2. Allura Xper FD10/10, Model Number 722005. 3. Allura Xper FD20, Model Number 722006. 4. All
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2516-2025·2025-09-10

    Spinal implant inserters recalled over potential missing pins at the tip

    TOPS Inserters, model 82889, part of the TOPS System Instrument Set, are recalled because of the potential for missing pins at the tip of the inserter. 30 units are affected.

    Product
    TOPS Inserter, part of the TOPS System Instrument Set used for implantation of the TOPS System. Model Number: 82889.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2493-2025·2025-09-10

    RayStation 12A planning software recalled over duplicate DICOM instance identifier risk

    RayStation 12A and its service packs are recalled because DICOM instance identifiers from the RayGateway interface to Accuray's iDMS are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 12A, Software Version: 13.0.0.1547. 2. RayStation 12A Service Pack 1, Software Version: 13.1.0.144. 3. RayStation 12A Service Pack 2, Software Version: 13.1.1.89. Product Description: Radiation Thera
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2514-2025·2025-09-10

    Dental titanium bases recalled because the post is oriented 180 degrees off

    NobelBiocare Tri-Lobe-compatible WP 6.0mm engaging titanium bases, lot 277097, are recalled because the base was manufactured 180 degrees around the post from the correct position. 11 units are affected.

    Product
    NobelBiocare Tri-Lobe-compatible WP X 6.0mm Engaging Titanium Base, REF: 9000662
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2491-2025·2025-09-10

    RayStation 11A planning software recalled over non-unique DICOM instance identifiers

    RayStation 11A and its service packs are recalled because DICOM instance identifiers from the RayGateway interface to Accuray's iDMS are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 11A, Software Version: 11.0.0.951. 2. RayStation 11A Service Pack 1, Software Version: 11.0.1.29. 3. RayStation 11A Service Pack 2, Software Version: 11.0.3.116. 4. RayStation 11A Service Pack 3, Softw
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2499-2025·2025-09-10

    Defibrillator recalled because required post-service inspections were not performed

    One LIFEPAK CR2 defibrillator is recalled because required inspections were not performed on units that had gone through servicing.

    Product
    LIFEPAK CR2 Part / Catalog Numbers / UDI-DI code: CR2-2-001451 99512-001434 883873785911 LIFEPAK CR2: The LIFEPAK CR2 defibrillator is indicated for use on patients 1 year of age or older in cardiopulmonary arrest. The patient must be unresponsive (unconscious), not breathin
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2492-2025·2025-09-10

    RayStation 11B software recalled over non-unique DICOM instance identifiers

    RayStation 11B and its service packs are recalled because DICOM instance identifiers from the RayGateway interface to Accuray's iDMS are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 11B, Software Version: 12.0.0.932. 2. RayStation 11B Service Pack 1, Software Version: 12.1.0.1221. 3. RayStation 11B Service Pack 2, Software Version: 12.0.3.68. 4. RayStation 11B Service Pack 3, Soft
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2490-2025·2025-09-10

    RayStation 10B planning software recalled over DICOM identifiers not guaranteed unique

    RayStation 10B and 10B Service Pack 1 radiation therapy treatment planning software is recalled because DICOM instance identifiers from the RayGateway interface are not guaranteed to be unique.

    Product
    RayStation with the following product descriptions: 1. RayStation 10B, Software Version: 10.1.0.613. 2. RayStation 10B Service Pack 1, Software Version: 10.1.1.54. Product Description: Radiation Therapy Treatment Planning System.
    Category
    Medical Device
    Distribution
    Distributed nationwide