The Recall Desk

State

Pennsylvania product recalls

73,100 recalls have nationwide distribution and so reach Pennsylvania. 11,926 additional recalls listed Pennsylvania specifically in their distribution scope.

What the numbers show

Total
11,926
Critical
1,922
Severe
2,869
Most recent
2026-09-25

Of the 11,926 recalls naming Pennsylvania we have scored against our rubric, 1,922 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,869 (24%) are Severe.

These figures cover only the 11,926 recalls whose distribution notice names Pennsylvania specifically. The 73,100 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

8926–8950 of 85026

  • HighFDA (Devices)·Z-0868-2025·2025-01-22

    Intuitive Surgical Bipolar Dissectors Recalled for Frayed Grip Cables

    Intuitive Surgical is recalling 141 curved bipolar dissectors due to complaints of frayed or broken grip cables on the reusable surgical instruments.

    Product
    8MM,CURVED BIPOLAR DISSECTOR,IS4000¿ REF 470344
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0855-2025·2025-01-22

    Intuitive Surgical Recalls 8MM Micro Bipolar Forceps Due to Frayed Grip Cables

    Intuitive Surgical is recalling 178 units of its 8MM Micro Bipolar Forceps (Model 470171) due to increased complaints of frayed or broken grip cables on the reusable instruments. Affected devices have been distributed nationwide and internationally.

    Product
    8MM,MICRO BIPOLAR FORCEPS,IS4000 ¿ REF 470171
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0881-2025·2025-01-22

    Intuitive Surgical Bipolar Dissector Recalled for Frayed Grip Cables

    Intuitive Surgical is recalling 8MM curved bipolar dissectors due to frayed or broken grip cables that could affect surgical instrument performance. Approximately 3,869 units were distributed nationwide and internationally.

    Product
    8MM,CURVED BIPOLAR DISSECTOR,IS4000 REF 471344
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0865-2025·2025-01-22

    Reusable Surgical Instruments Recalled for Frayed or Broken Grip Cables

    Intuitive Surgical is recalling reusable surgical instruments due to reports of frayed or broken grip cables that may affect safe operation during procedures.

    Product
    8MM,MEGA SUTURECUT ND,IS4000¿ REF 470309
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0882-2025·2025-01-22

    Intuitive Surgical Bipolar Grasper Recall Due to Frayed or Broken Grip Cables

    Intuitive Surgical is recalling 14,507 8MM Long Bipolar Graspers due to increased complaints of frayed or broken grip cables that could impair surgical control during laparoscopic procedures.

    Product
    8MM,LONG BIPOLAR GRASPER,IS4000 REF 471400
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0854-2025·2025-01-22

    Prograsp Surgical Forceps Recalled Due to Frayed Grip Cables

    Intuitive Surgical is recalling 2,852 units of 8MM Prograsp Forceps due to complaints of frayed or broken grip cables. These reusable surgical instruments may lose grip control during use.

    Product
    8MM,PROGRASP FORCEPS,IS4000 ¿ REF 470093
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0925-2025·2025-01-22

    ECONO STERILE ear cleaning kits recalled for packaging sterile barrier issues

    Sklar Instruments is recalling ECONO STERILE medical procedure kits for ear cleaning due to packaging issues that may result in a breach of the sterile barrier. The kits have been distributed nationwide.

    Product
    ECONO STERILE brand medical procedure kits labeled as: 1) ECONO STERILE" BUCK EAR CUR BL STR#0STRLCS/25, Model Number 96-2273; 2) ECONO STERILE" BILLEAU EAR LOOP MD STRL CS/25, Model Number 96-2283; for ear cleaning
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0926-2025·2025-01-22

    ECONO STERILE Medical Procedure Kits Recalled for Packaging Defects

    Sklar Instruments is recalling ECONO STERILE medical procedure kits due to packaging issues that may compromise the sterile barrier and allow contamination.

    Product
    ECONO STERILE brand medical procedure kits labeled as: 1) ECONO STERILE FREER ELEV DE S/B 7.25" CS/25, Model Number 96-2483 (multiple purpose); 2) ECONO STERILE LOCKE ELEV #94 NARROW STER 25, Model Number 96-2484 (foot procedures)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0904-2025·2025-01-22

    Medtronic NanoCross Elite PTA Catheter Recall Due to Balloon Deflation

    Medtronic's NanoCross Elite PTA catheters in certain lots may not deflate properly during use. The FDA is recalling 5,189 units due to potential in-vivo balloon deflation issues.

    Product
    Medtronic NanoCross Elite PTA catheter, REF numbers amd sizes: 1) AB14W050020090, Size: 5MM X 20MM X 90CM; 2) AB14W050020150, Size: 5MM X 20MM X 150CM; 3) AB14W050040090, Size: 5MM X 40MM X 90CM; 4) AB14W050040150, Size: 5MM X 40MM X 150CM; 5) AB14W050060150,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0916-2025·2025-01-22

    Cardinal Health Presource Surgical Kits Recalled for Potential Endotoxin Contamination

    Cardinal Health is recalling Presource surgical kits due to potential endotoxin contamination in non-sterile surgical strips and patties. The recall affects 512,786 units distributed worldwide.

    Product
    Cardinal Health Presource Kits: 1) ORTHO PLASTIC MICROVASCULAR PK , Catalog Number: PGVMFFBLY; 2) ORTHO PLASTIC MICROVASCULAR PK , Catalog Number: PGVMFFBLZ; 3) KIT,NEURO SPINE,ANDERSON , Catalog Number: PN23SPAM5; 4) KIT, MAJOR SPINE , Catalog Number: PN33MSOC3; 5) KIT, MAJOR
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0853-2025·2025-01-22

    Surgical Forceps Recalled Due to Frayed or Broken Grip Cables

    Intuitive Surgical is recalling 8,578 units of Cadiere Forceps surgical instruments due to reports of frayed or broken grip cables. These reusable instruments were distributed throughout the United States and internationally.

    Product
    8MM,CADIERE FORCEPS,IS4000 ¿ REF 470049
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0932-2025·2025-01-22

    ECONO STERILE Nail Nippers and Tissue Nippers Recalled for Sterile Barrier Issues

    Sklar Instruments is recalling ECONO STERILE nail nipper and tissue nipper kits due to packaging defects that may compromise their sterile barrier. The affected kits were distributed nationwide.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE D/A NAIL NIPPER 5.75" STER CS5, Model Number 96-2424A; 2) ECONO STERILE TISS NIPPER 14MM CVX 5"CS/25, Model Number 96-2427; 3) ECONO STERILE NAIL NIPPER 4.5" STERILE 25, Model Number 96-2666; 4) ECONO STER
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0929-2025·2025-01-22

    Surgical Retractor Kits Recalled for Potential Sterile Barrier Breach

    Sklar Instruments is recalling ECONO STERILE surgical retractor kits due to packaging defects that may result in a breach of the sterile barrier. 75 units nationwide have been affected.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE WEITLANER RETR SH 2X3 4.5"CS25, Model Numbers: 96-2201A; 2) ECONO STERILE WEITLANER RETR BL 2X3 4.5"CS25, Model Numbers: 96-2203A; 3) ECONO STERILE WEITLANER RETR BL 3X4 5.5"CS25, Model Numbers: 96-2207A;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0874-2025·2025-01-22

    ProGrasp Forceps Recalled Due to Frayed or Broken Grip Cables

    Intuitive Surgical recalls ProGrasp Forceps instruments due to increased complaints of frayed or broken grip cables. Approximately 99,249 units distributed in the U.S. and internationally are affected.

    Product
    8MM,PROGRASP FORCEPS,IS4000 REF 471093
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0945-2025·2025-01-22

    Gynecological Procedure Kits Recalled for Potential Sterile Barrier Packaging Defects

    Sklar Instruments is recalling ECONO STERILE gynecological procedure kits due to packaging issues that may compromise the sterile barrier. The affected kits may no longer maintain their sterile condition.

    Product
    ECONO STERILE medical procedure kits labeled as: ECONO STERILE KOGAN ENDOCERV SPEC STER CS/5, Model Number 96-4142A, gynecological procedures
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0914-2025·2025-01-22

    Cardinal Health Fetal Surgery Kits Recalled for Endotoxin Contamination Risk

    Cardinal Health is recalling Presource fetal surgery kits due to potential endotoxin contamination in non-sterile surgical strips and patties, which could pose infection risk.

    Product
    Cardinal Health Presource Kits: 1 ) KIT, FETAL SURGERY, Catalog Number PB11FSC10 2 ) KIT, FETAL SURGERY , Catalog Number PB11FSCH5 3 ) KIT, FETAL SURGERY , Catalog Number PB11FSCH6 4 ) KIT, FETAL SURGERY , Catalog Number PB11FSCH7 5 ) KIT, FETAL SURGERY , Catalog Number PB11
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0949-2025·2025-01-22

    Sklar Instruments ECONO STERILE surgical procedure kits recalled due to packaging defect

    Sklar Instruments is recalling ECONO STERILE ALFONSO INFANT SPEC STRL sterile surgical procedure kits nationwide due to packaging issues that may breach the sterile barrier.

    Product
    ECONO STERILE medical procedure kits labeled as: ECONO STERILE ALFONSO INFANT SPEC STRL CS/10, Model Number 96-3814; eyelid surgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0928-2025·2025-01-22

    Sklar Instruments Recalls ECONO STERILE Gynecological Procedure Kits for Packaging Defects

    Sklar Instruments is recalling ECONO STERILE gynecological procedure kits (Model 96-2478) due to packaging issues that may breach the sterile barrier and create contamination risk.

    Product
    ECONO STERILE medical procedure kits labeled as: ECONO STERILE SIMS UTERINE SND GRD 13"STER25, Model Numbers: 96-2478 (gynecological use)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0953-2025·2025-01-22

    ECONO STERILE Orthopedic Probes Recalled for Sterile Barrier Breach Risk

    Sklar Instruments recalls 2,500 ECONO STERILE orthopedic probe kits due to packaging issues that may breach the sterile barrier. No illnesses or injuries have been reported.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE PROBE W/EYE CS/50, Model Number 94-5923; 2) ECONO STERIL" PROBE W/EYE 5.5" STERL CS/25, Model Number 96-2361; orthopedic probe
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0879-2025·2025-01-22

    Intuitive Surgical Needle Driver Recall Due to Grip Cable Failures

    Intuitive Surgical is recalling 8MM Large Suture Cut Needle Drivers (Model 471296) due to complaints of frayed or broken grip cables. Affected instruments may lose functionality during surgical use.

    Product
    8MM,LARGE SUTURECUT NEEDLE DRIVER,IS4000 REF 471296
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0923-2025·2025-01-22

    Tenaculum Forceps for da Vinci Surgical Systems Recalled Due to Pitch Cable Failures

    Intuitive Surgical is recalling 8MM Tenaculum Forceps used with da Vinci X/Xi Surgical Systems due to pitch cable failures. These instruments are used for tissue manipulation and retraction during surgical procedures.

    Product
    8MM, Tenaculum Forceps REF 470207 Instrument used with the da Vinci X/Xi Surgical Systems in a wide variety of procedures to perform a variety of surgical tasks including manipulation and retraction of tissue.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0924-2025·2025-01-22

    FDA Recalls Small Graptor Retractor Instruments Due to Cable Failures

    Intuitive Surgical is recalling 42,028 Small Graptor surgical retractor instruments used with da Vinci X/Xi systems due to pitch cable failures. The recalled devices affect surgical facilities nationwide and internationally.

    Product
    8MM, Small Graptor REF 470318 Is a grasping retractor Instrument used with the da Vinci X/Xi Surgical Systems in a wide variety of procedures to perform a variety of surgical tasks including manipulation and retraction of tissue.
    Category
    Medical Device
    Distribution
    Distributed nationwide