The Recall Desk

State

Oklahoma product recalls

73,213 recalls have nationwide distribution and so reach Oklahoma. 5,816 additional recalls listed Oklahoma specifically in their distribution scope.

What the numbers show

Total
5,816
Critical
1,043
Severe
1,250
Most recent
2026-09-23

Of the 5,816 recalls naming Oklahoma we have scored against our rubric, 1,043 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,250 (21%) are Severe.

These figures cover only the 5,816 recalls whose distribution notice names Oklahoma specifically. The 73,213 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

13876–13900 of 79029

  • SevereFDA (Drugs)·D-0209-2024·2024-01-03

    Sure Regular Antiperspirant Deodorant Aerosol Recalled for Benzene Contamination

    Sure Regular Antiperspirant Deodorant Aerosol (6 oz cans) sold nationwide in the US and Canada is being recalled due to benzene contamination. All lots expiring on or before August 2023 are affected.

    Product
    Sure Regular Antiperspirant Deodorant Aerosol (Aluminum Chlorohydrate 10%), packaged in 6 oz (170 g) aerosol cans, Distributed by Idelle Labs, Ltd., El Paso, TX 79912, NDC 41595-5518-06
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0561-2024·2024-01-03

    Medline Tracheostomy Care Kits Recalled for Sharp Brush and Bristle Detachment

    Medline is recalling 620,735 tracheostomy care kits because the brush component has a sharp edge that can puncture tubing and injure users, and bristles can detach during use.

    Product
    Tracheostomy care kits: (1) Medline Tracheostomy Clean and Care Tray with 14 Fr Suction Catheter, REF DYND40580, Sterile; (2) Medline Tracheostomy Clean and Care Tray, REF DYND4061030, Sterile; (3) Medline Basic Tracheostomy Care Kit, REF CC3T4691A, Sterile; (4)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0562-2024·2024-01-03

    Medline Nursing Skills Kit: Tracheostomy Brush Sharp Edge and Bristle Defect

    Medline is recalling 172 Nursing Skills kits due to defects in the tracheostomy brush component. The brush has a sharp edge that can puncture tubing and cause user injury, and bristles may detach during use.

    Product
    (1) Nursing Skills kit, SKU #EDUC05038B, Case UPC 40195327019878, Non-sterile, For Training Purposes Only, Not For Human Use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0563-2024·2024-01-03

    Medline Nurse Training Kits Recalled for Sharp Tracheostomy Brush

    Medline Industries recalls 550 educational nurse training kits due to sharp edges on tracheostomy brush components that can puncture tubing or cause injury, and bristles that may detach during or before use.

    Product
    (1) Nurse Kit, SKU #EDUC1025, Case UPC 40195327196647, Non-sterile, For Training Purposes Only, Not For Human Use.; and (2) Nursing Tote Kit, SKU #EDUC5056A, Case UPC 40195327153695, Non-sterile, For Training Purposes Only, Not For Human Use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E001000·2024-01-03

    Spektrum Brakes Recalls Dynamic Friction R1 Brake Rotors Due to Fracture Risk

    Spektrum Brakes is recalling Dynamic Friction R1 brake rotors because the hub can fracture, causing a loss of braking ability and increasing crash risk.

    Product
    SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DISC:ROTOR recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0207-2024·2024-01-03

    Brut Classic Antiperspirant and Deodorant Recalled for Benzene Contamination

    Brut Classic Antiperspirant & Deodorant in 4 oz and 6 oz aerosol cans is being recalled due to benzene contamination. The recall affects all lots distributed in the United States and Canada.

    Product
    Brut Classic Antiperspirant & Deodorant (aluminum chlorohydrate 20.9%) packaged in a) 4 oz. (113g) aerosol cans (UPC 00827755070085, NDC 41595-7103-1) and b) 6 oz. (170g) aerosol cans (UPC 00827755070108, NDC 41595-7103-2), Distributed by Idelle Labs, Ltd. El Paso, TX 79912 USA
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0598-2024·2024-01-03

    Megadyne Patient Return Electrodes Recalled Due to Serious Burn Risk

    Megadyne Medical Products recalls its MEGA SOFT Universal Dual Patient Return Electrode due to reports of severe burn injuries, including third-degree burns requiring medical intervention. Use is now restricted to patients age 12 and older.

    Product
    Product Code 0846, MEGADYNE MEGA SOFT Universal Dual Patient Return Electrode, Reusable Patient Return Electrode, Mega Soft Universal Dual Cord
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0206-2024·2024-01-03

    Supplement Capsules Recalled for Undeclared Sildenafil Content Nationwide

    Magnum XXL 9800 capsules contain undeclared sildenafil and were marketed without FDA approval. The product was distributed nationwide via Amazon.

    Product
    Magnum XXL 9800, 2000 mg per capsule, 1 capsule per blister pack, Distributed by Magnum Los Angelas CA. UPC 6 45759 99300 7. Amazon's ASIN# B07P7ZH797, B07P94J3ZT, B07P6VK6N3, B076HNPZZZ
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0621-2024·2024-01-03

    Atrium Oasis surgical drain recalled for premature sterilization expiration

    Atrium Oasis surgical drain recalled due to sterilization nonconformance that shortened the product's shelf life. Affected units were distributed nationwide and may not maintain sterility if used after November 17, 2025.

    Product
    Atrium Oasis Drain Single W / AC, Part No. 3600-100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0192-2024·2024-01-03

    Topical antifungal Nyamyc recalled due to storage temperature deviations

    Cardinal Healthcare is recalling Nyamyc topical antifungal medication (Batch 400454) nationwide due to exposure to temperatures outside labeled storage conditions.

    Product
    Nyamyc, 100,000 USP units per gram, 60 grams, Rx only, Topical Use Only, Manufactured by: Upsher-Smith Laboratories, Inc, Minneapolis, MN 55447.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0180-2024·2024-01-03

    Estradiol 0.5mg Tablets Recalled Nationwide for Storage Temperature Deviation

    Cardinal Healthcare is recalling Estradiol 0.5mg tablets (Batch 100023687) nationwide due to exposure to temperatures outside labeled storage specifications. Temperature exposure may affect medication stability.

    Product
    ESTRADIOL — ESTRADIOL (ESTRADIOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0176-2024·2024-01-03

    Donepezil Hydrochloride tablets recalled for improper storage temperature

    Donepezil Hydrochloride 10mg tablets are recalled due to exposure to temperatures outside labeled storage conditions. The FDA classified this Class II recall due to potential effects on drug stability.

    Product
    DONEPEZIL HYDROCHLORIDE — DONEPEZIL HYDROCHLORIDE (DONEPEZIL HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0613-2024·2024-01-03

    Alinity ci-series System Control Module Software Performance Issues Recalled

    Abbott Laboratories is recalling 8,424 Alinity ci-series System Control Module units due to software performance issues that could produce erroneous test results. Affected systems are used in clinical laboratories throughout the United States and 90+ countries.

    Product
    Alinity ci-series System Control Module, REF: 03R70-01
    Category
    Medical Device
    Distribution
    46 states
  • HighFDA (Drugs)·D-0202-2024·2024-01-03

    Prescription Inhalation Powder Recalled for Storage Temperature Deviation

    Cardinal Healthcare recalls batch 62002532 of Wixela Inhub inhalation powder nationwide due to CGMP deviations. Products were exposed to temperatures outside labeled storage conditions, potentially affecting product stability.

    Product
    WIXELA INHUB — WIXELA INHUB (FLUTICASONE PROPIONATE AND SALMETEROL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0161-2024·2024-01-03

    Respiratory inhalation medication recalled for temperature storage deviation

    Cardinal Healthcare is recalling an ipratropium bromide and albuterol sulfate inhalation solution nationwide after the product was exposed to temperatures outside labeled storage conditions. The deviation may affect drug potency.

    Product
    IPRATROPIUM BROMIDE AND ALBUTEROL SULFATE — IPRATROPIUM BROMIDE AND ALBUTEROL SULFATE (IPRATROPIUM BROMIDE AND ALBUTEROL SULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0618-2024·2024-01-03

    Acumed RibLoc U Plus 90 Surgical Guide Recalled for Potential Breakage

    Acumed LLC recalls 513 RibLoc U Plus 90 surgical guides due to potential breakage during use. The device is used in orthopedic rib fixation procedures.

    Product
    RibLoc U Plus 90 Instrument PRIMARY GUIDE ASSY, LOW PROFILE REF RBL2320 The RBL2320, Low Profile Primary Guide is an instrument used with a power system to compress the RibLoc plates onto the bone, determine the length of the screw to install, locate the position of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0188-2024·2024-01-03

    FDA Recalls Lisinopril and Hydrochlorothiazide Tablets Due to Temperature Storage Deviations

    Cardinal Healthcare is recalling Lisinopril and Hydrochlorothiazide Tablets (10mg/12.5mg) manufactured by Lupin Limited because products were exposed to temperatures outside the labeled storage conditions. Affected batches are Q101699 and Q101981 distributed nationwide.

    Product
    LISINOPRIL AND HYDROCHLOROTHIAZIDE — LISINOPRIL AND HYDROCHLOROTHIAZIDE (LISINOPRIL AND HYDROCHLOROTHIAZIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0204-2024·2024-01-03

    FDA Recalls AnazaoHealth Injectable Vitamin Solution Due to Particulate Matter

    AnazaoHealth Corporation is recalling 3,363 vials of Thiamine HCl/Pyridoxine HCl injection solution nationwide due to the presence of particulate matter. Affected lots are identified by lot numbers and expiration dates listed by the FDA.

    Product
    Thiamine HCl/Pyridoxine HCl 20 mg/mL /100mg/ml Injection Solution, 30mL Amber Glass Vial, Rx only, AnazaoHealth, 7465 W. Sunset Road, Las Vegas, NV, NDC 72682-8721-3.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0179-2024·2024-01-03

    Enoxaparin Sodium Injection recalled due to improper storage conditions

    Sandoz Inc is recalling Enoxaparin Sodium Injection (batch SAH06821A) nationwide due to CGMP deviations: products were exposed to temperatures outside labeled storage conditions, potentially affecting drug stability.

    Product
    ENOXAPARIN SODIUM — ENOXAPARIN SODIUM (ENOXAPARIN SODIUM)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0177-2024·2024-01-03

    Donepezil Hydrochloride Tablets Recalled Due to Storage Temperature Deviations

    Cardinal Healthcare is recalling Donepezil Hydrochloride 5 mg tablets (Batch 17605) distributed nationwide because they were exposed to temperatures outside labeled storage conditions, which could affect drug stability.

    Product
    DONEPEZIL HYDROCHLORIDE — DONEPEZIL HYDROCHLORIDE (DONEPEZIL HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0203-2024·2024-01-03

    B-Complex Vitamin Injection Vials Recalled for Particulate Matter

    AnazaoHealth is recalling B-Complex injection vials due to particulate matter contamination. Affected patients should discontinue use and consult their healthcare provider.

    Product
    B-Complex, Thiamine HCI / Riboflavin / Niacinamide / Dexpanthenol / Pyridoxine HCI injection, 74/2/75/2/2 MG/ML, 30ML Sterile Multiple-Dose Vial, Rx only, AnazaoHealth, 7465 W Sunset Rd #1200, Las Vegas, NV 89113, NDC 72682-2230-3
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0163-2024·2024-01-03

    Albuterol Sulfate Inhaler Recalled Due to Temperature Storage Deviation

    Cardinal Healthcare is recalling Albuterol Sulfate inhalers (Batch K100715) due to CGMP deviations where products were exposed to temperatures outside labeled storage conditions. Approximately 11 cartons were distributed nationwide. Contact your pharmacist or doctor for a replacement.

    Product
    ALBUTEROL SULFATE — ALBUTEROL SULFATE (ALBUTEROL SULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0201-2024·2024-01-03

    Warfarin Sodium Tablets Recalled Due to Temperature Storage Deviation

    Cardinal Healthcare recalls Warfarin Sodium Tablets (5 mg) nationwide due to CGMP deviations: products were exposed to temperatures outside labeled storage conditions, potentially affecting drug stability.

    Product
    WARFARIN SODIUM — WARFARIN SODIUM (WARFARIN SODIUM)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0196-2024·2024-01-03

    Rivastigmine Transdermal Patch Recalled Due to Temperature Exposure

    Cardinal Healthcare is recalling Rivastigmine Transdermal System patches (4.6 mg/24 hours) distributed nationwide because they were exposed to temperatures outside labeled storage conditions during manufacturing.

    Product
    RIVASTIGMINE TRANSDERMAL SYSTEM, Delivers 4.6 mg/24 hours, 30 systems per box, Rx Only, Distributed by: Alvogen, Inc., Morristown, NJ 07960. NDC 47781-304-03
    Category
    Drug
    Distribution
    Distributed nationwide