  • CriticalFDA (Devices)·Z-0830-2025·2025-01-22

    Impella RP Flex Devices Recalled Due to Optical Sensor Damage Risk

    Abiomed is recalling 2,364 units of the Impella RP Flex with SmartAssist due to risk of optical sensor damage from device interaction. Damage may cause temporary or permanent pump stop and loss of vital monitoring signals.

    Product
    Impella RP Flex with SmartAssist; Product Number: 1000323;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0825-2025·2025-01-22

    ALTRUA 2 DR Pacemaker Models S702 and S722 Safety Mode Risk

    Boston Scientific ALTRUA 2 DR Pacemakers may unexpectedly enter Safety Mode during normal operation due to high battery impedance, potentially affecting device functionality.

    Product
    ALTRUA 2 DR Pacemaker, SL (Model Number S702) and EL (Model Number S722)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0887-2025·2025-01-22

    Life2000 Ventilation System battery charger defect causes device inoperability

    Baxter Healthcare is recalling the Life2000 Ventilation System due to a battery charger defect that can trigger an alarm, rendering the ventilator inoperable and unable to support patients' breathing.

    Product
    Breathe Technologies, Inc., Life2000 Ventilation System, REF BT-20-0002AP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0200-2025·2025-01-22

    Systane Lubricant Eye Drops Recalled for Non-Sterility Risk

    Alcon Research is voluntarily recalling Systane Lubricant Eye Drops, Ultra PF, due to non-sterility concerns. The recall affects 55,960 boxes distributed nationwide.

    Product
    Systane Lubricant Eye Drops, Ultra PF, Sterile, 25 Vials (0.7mL Each), Manufactured for: Alcon Laboratories, Inc. Forth Worth, TX 76134
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0829-2025·2025-01-22

    Impella RP Heart Pump Recalled Due to Optical Sensor Damage Risk

    Abiomed is recalling 1,560 units of the Impella RP with SmartAssist pump due to risk of optical sensor damage from device interactions. Damaged sensors may cause temporary or permanent pump malfunction.

    Product
    Impella RP with SmartAssist; Product Number: 0046-0035;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0905-2025·2025-01-22

    Olympus MAJ-891 Forceps Recalled for Potential Biomaterial Retention During Reprocessing

    Olympus recalls the MAJ-891 endoscope forceps/irrigation plug nationwide because improper reprocessing may leave biomaterial inside the device, creating a contamination risk.

    Product
    Olympus MAJ-891 Forceps/Irrigation Plug (Isolated Type). Model/Catalog Number: MAJ-891. This instrument is designed to be attached to the instrument channel port of Olympus endoscopes to allow both irrigation and the use of endo-therapy accessories.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0831-2025·2025-01-22

    Dialysis Blood Circuit May Cause Excessive Fluid Removal

    The AquaFlexFlow UF 500 Plus blood circuit may malfunction and remove excessive fluid from patients, causing a dangerous drop in blood volume. This risk is especially dangerous for pediatric patients.

    Product
    nuwellis AquaFlexFlow UF 500 Plus, REF 114156, Catalog Number A06163, extracorporeal blood circuit which is used with the Aquadex SmartFlow or Aquadex FlexFlow System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0885-2025·2025-01-22

    Welch Allyn Life2000 Ventilator Battery Charger May Cause Device Inoperability

    Baxter Healthcare is recalling 946 Welch Allyn Life2000 ventilators due to a battery charger defect that can trigger an alarm and render the device inoperable.

    Product
    Welch Allyn, Inc., Life2000 Ventilation System, REF BT-20-0002A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0886-2025·2025-01-22

    Welch Allyn Life2000 Ventilator Battery Charger Malfunction Recall

    Baxter Healthcare Corporation is recalling Welch Allyn Life2000 Ventilation Systems due to a battery charger malfunction that triggers an alarm and renders the ventilator inoperable.

    Product
    Welch Allyn, Inc., Life2000 Ventilation System, REF BT-20-0002AP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0821-2025·2025-01-22

    Neo-Tee Resuscitator Spring Defect May Impair Pediatric Ventilation

    Mercury Medical is recalling the Neo-Tee T-Piece Resuscitator due to an undersized spring in the circuit flow controller that may prevent reaching proper pressure ranges, potentially impairing emergency ventilation.

    Product
    Neo-Tee T-Piece Resuscitator, for pediatric emergency respiratory support, Part: 1050805, 1050808, 1050809, 1050810, 1050811, 1050814, 1050832, 1050839, 1050840, 1050841, 1050842
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0764-2025·2025-01-22

    Medline Fluid Delivery Sets incorrectly assembled with wrong drip chamber

    Medline fluid delivery sets were assembled with a macro drip chamber instead of the required micro drip chamber, delivering three times more fluid per drop and risking patient fluid overload.

    Product
    Medline Fluid Delivery Set with Drip Chamber: 1) FDS,135,CHMN,W/F,MLL,RC(2),PG, Item Number 99000069; 2) FDS,135,NV,MICRO-CHAMBER,W/FILTER,BLUE, Item Number 949000222; 3) FDS,135,NV,MICRO-CHAMBER,W/FILTER,GREEN, Item Number 949000224; 4) FDS,135,NV,MICRO-CHAMBER,W/FILTER,RE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0822-2025·2025-01-22

    ACCOLADE DR Pacemakers Recalled for Unintended Safety Mode Activation

    Boston Scientific is recalling ACCOLADE DR Pacemakers built before September 2018 due to risk of unintended Safety Mode activation caused by battery impedance issues. The devices may enter Safety Mode during normal telemetry operations.

    Product
    ACCOLADE DR Pacemaker, SL (Model Number L301), SL MRI (Model Number L311), EL (Model Number L321), and EL MRI (Model Number L331)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0824-2025·2025-01-22

    ESSENTIO DR Pacemakers May Malfunction Due to Battery Impedance Issue

    Boston Scientific is recalling certain ESSENTIO DR Pacemakers manufactured before September 2018 due to latent battery impedance that may cause Safety Mode malfunction during normal operations.

    Product
    ESSENTIO DR Pacemaker, SL (Model Number L101, SL MRI (Model Number L111), EL (Model Number L121), and EL MRI (Model Number L131)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0827-2025·2025-01-22

    VISIONIST CRT-P Pacemakers Recalled Due to Battery Impedance Risk

    Certain VISIONIST CRT-P pacemakers with latent high battery impedance may initiate Safety Mode unexpectedly during normal operations. Manufactured before September 2018, 156,329 units were distributed worldwide.

    Product
    VISIONIST CRT-P, EL (Model Number U225 and U226) and EL MRI (Model Number U228)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0765-2025·2025-01-22

    Medline Fluid Delivery Sets Recalled Due to Assembly Error

    Medline Fluid Delivery Sets were incorrectly assembled with macro drip chambers instead of required micro drip chambers. The macro chamber delivers three times more fluid per drop, creating a risk of dosing errors.

    Product
    Medline Fluid Delivery Set with Drip Chamber: 1) MTO,135,YELLOW,MICRO,SPK-MAIMONIDES, Item Number: 60130527; 2) MTO,ANGIO,DOUBLE,SPIKE,KIT,KENNEDY HLTH, Item Number: 65111341; 3) MTO,ANGIO,SINGLE,SPIKE,KIT, Item Number: 65232486; 4) MTO,ANGIO,SINGLE,SPIKE,KIT,GOOD,SAM, Item
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0398-2025·2025-01-22

    Daily Veggies Enoki Mushroom Recalled for Possible Listeria Contamination

    New Age International recalls Daily Veggies Enoki Mushrooms due to potential Listeria monocytogenes contamination. The product was distributed in New York and Maryland; consumers should not consume it.

    Product
    Daily Veggies Enoki Mushroom, 200g Product of Korea UPC Codes: 8809159458890
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Devices)·Z-0826-2025·2025-01-22

    CRT-P Pacemakers Recalled for Potential Safety Mode Initiation Risk

    Boston Scientific's ACCOLADE Family pacemakers, including VALITUDE CRT-P models, are recalled due to battery impedance defects that could trigger unintended Safety Mode during normal operation.

    Product
    VALITUDE CRT-P, EL (Model Number U125) and EL MRI (Model Number U128)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0907-2025·2025-01-22

    Panther Fusion GBS Assay Kits with Weak Cartridge Seals May Produce Invalid Results

    Hologic is recalling 380 Panther Fusion GBS Assay Kits due to potential weak pouch seals on the reagent cartridge. The seals may allow invalid or incorrect test results, potentially delaying necessary treatment.

    Product
    Panther Fusion GBS Assay REF PRD-04484 Kit containing Panther Fusion GBS Reagent Cartridge IVD.
    Category
    Medical Device
    Distribution
    20 states
  • HighFDA (Devices)·Z-0949-2025·2025-01-22

    Sklar Instruments ECONO STERILE surgical procedure kits recalled due to packaging defect

    Sklar Instruments is recalling ECONO STERILE ALFONSO INFANT SPEC STRL sterile surgical procedure kits nationwide due to packaging issues that may breach the sterile barrier.

    Product
    ECONO STERILE medical procedure kits labeled as: ECONO STERILE ALFONSO INFANT SPEC STRL CS/10, Model Number 96-3814; eyelid surgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0945-2025·2025-01-22

    Gynecological Procedure Kits Recalled for Potential Sterile Barrier Packaging Defects

    Sklar Instruments is recalling ECONO STERILE gynecological procedure kits due to packaging issues that may compromise the sterile barrier. The affected kits may no longer maintain their sterile condition.

    Product
    ECONO STERILE medical procedure kits labeled as: ECONO STERILE KOGAN ENDOCERV SPEC STER CS/5, Model Number 96-4142A, gynecological procedures
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0862-2025·2025-01-22

    Surgical Retractor Grip Cables May Fray or Break During Use

    Intuitive Surgical is recalling 738 units of the 8MM Atrial Retractor (Model 470246) due to reports of frayed or broken grip cables on reusable instruments. The defect could compromise instrument performance during surgical procedures.

    Product
    8MM,ATRIAL RETRACTOR SHORT RIGHT,IS4000¿ REF 470246
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0823-2025·2025-01-22

    PROPONENT DR Pacemaker Recalled for Unexpected Safety Mode Risk

    Boston Scientific is recalling certain PROPONENT DR pacemakers built before September 2018 due to latent battery impedance that could cause unexpected Safety Mode initiation during normal operation.

    Product
    PROPONENT DR Pacemaker, SL (Model Number L201), (VDD) SL (Model Number L209), SL MRI (Model Number L211), EL (Model Number L221), and EL MRI (Model Number L231).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0874-2025·2025-01-22

    ProGrasp Forceps Recalled Due to Frayed or Broken Grip Cables

    Intuitive Surgical recalls ProGrasp Forceps instruments due to increased complaints of frayed or broken grip cables. Approximately 99,249 units distributed in the U.S. and internationally are affected.

    Product
    8MM,PROGRASP FORCEPS,IS4000 REF 471093
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0914-2025·2025-01-22

    Cardinal Health Fetal Surgery Kits Recalled for Endotoxin Contamination Risk

    Cardinal Health is recalling Presource fetal surgery kits due to potential endotoxin contamination in non-sterile surgical strips and patties, which could pose infection risk.

    Product
    Cardinal Health Presource Kits: 1 ) KIT, FETAL SURGERY, Catalog Number PB11FSC10 2 ) KIT, FETAL SURGERY , Catalog Number PB11FSCH5 3 ) KIT, FETAL SURGERY , Catalog Number PB11FSCH6 4 ) KIT, FETAL SURGERY , Catalog Number PB11FSCH7 5 ) KIT, FETAL SURGERY , Catalog Number PB11
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0923-2025·2025-01-22

    Tenaculum Forceps for da Vinci Surgical Systems Recalled Due to Pitch Cable Failures

    Intuitive Surgical is recalling 8MM Tenaculum Forceps used with da Vinci X/Xi Surgical Systems due to pitch cable failures. These instruments are used for tissue manipulation and retraction during surgical procedures.

    Product
    8MM, Tenaculum Forceps REF 470207 Instrument used with the da Vinci X/Xi Surgical Systems in a wide variety of procedures to perform a variety of surgical tasks including manipulation and retraction of tissue.
    Category
    Medical Device
    Distribution
    Distributed nationwide