The Recall Desk

State

Nevada product recalls

73,100 recalls have nationwide distribution and so reach Nevada. 5,696 additional recalls listed Nevada specifically in their distribution scope.

What the numbers show

Total
5,696
Critical
951
Severe
1,479
Most recent
2026-09-25

Of the 5,696 recalls naming Nevada we have scored against our rubric, 951 (17%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,479 (26%) are Severe.

These figures cover only the 5,696 recalls whose distribution notice names Nevada specifically. The 73,100 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

10176–10200 of 78796

  • HighFDA (Devices)·Z-2948-2024·2024-09-11

    BD Pyxis QFill Medication Cabinet Software Bug Causes Incorrect Restock Labels

    The BD Pyxis QFill Replenishment Station medication cabinet has a software issue that may print incorrect bin information on restock labels for medications stored in non-CUBIE locations.

    Product
    BKIT BD Pyxis QFill Replenishment Station, REF: 155197-01, medication cabinet system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2980-2024·2024-09-11

    Beckman Power Express Centrifuge Sample Holder May Detach During Operation

    An adhesive joint failure in the PE Centrifuge Temperature Controlled component can cause the metal part to detach inside the centrifuge, risking sample destruction and potential exposure of laboratory technicians to biohazardous material.

    Product
    PE Centrifuge Temperature Controlled, REF: B36366, a component of the Power Express.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0650-2024·2024-09-11

    Compounded semaglutide injection recalled due to sterility concerns

    ProRx LLC is recalling compounded semaglutide injections due to lack of assurance of sterility. The recall affects 2,490 vials distributed nationwide.

    Product
    Semaglutide, 2 mL (2.5mg/mL), Compounded RX Product, Multidose SC inj, glass vial, ProRx, 267-565-7008, NDC 84139-225-01
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2964-2024·2024-09-11

    Pump 381 Pump Set lacks labeling for Shockwave catheter interaction risk

    Abiomed's Pump 381 Pump Set labeling lacks information about potential interactions with Shockwave Coronary IVL Catheters during coronary interventions. The manufacturer is updating instructions for use to address this gap.

    Product
    Pump 381 Pump Set (US); Product Code: 1000080;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2956-2024·2024-09-11

    Impella CP Pump Set Recalled for Potential Device Interaction

    Abiomed is recalling the Impella CP Pump Set due to a potential device interaction with the Shockwave Coronary IVL Catheter during coronary interventions. The manufacturer will update device instructions to address this interaction.

    Product
    Impella CP Pump Set, Japan; Product Code: 0048-0034-JP;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2979-2024·2024-09-11

    Power Express PE Centrifuge adhesive joint failure may cause component detachment

    The adhesive joint in this medical device component can fail, causing the metal part to detach. This may damage the centrifuge, destroy patient samples, and potentially expose lab staff to biohazardous material.

    Product
    PE Centrifuge, REF: B36365, a component of the Power Express
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2955-2024·2024-09-11

    Impella CP Smart Assist Set Lacks Labeling for Potential Device Interaction

    Abiomed is updating labeling for the Impella CP Smart Assist Set to warn about a potential interaction with the Shockwave Coronary IVL Catheter when used during coronary interventions. The interaction was previously undocumented in the device instructions.

    Product
    Impella CP Smart Assist Set, JP; Product Code: 0048-0024-JP;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2965-2024·2024-09-11

    Impella 5.5 Device Recalled for Missing Labeling on Catheter Interaction

    Abiomed is updating labeling for Impella 5.5 cardiac support pumps to include information about a potential device interaction with Shockwave Coronary IVL Catheters during coronary interventions.

    Product
    Impella 5.5 with SmartAssist S2 Set, US; Product Code: 1000100;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2947-2024·2024-09-11

    BD Pyxis QFill Medication Cabinet Software Issue Causes Incorrect Bin Labeling

    A software bug in BD Pyxis QFill medication cabinet systems may print incorrect medication bin labels during restocking, potentially causing medication errors. Three units are affected.

    Product
    BD Pyxis QFill Replenishment Station, REF: 138904-01, medication cabinet system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2961-2024·2024-09-11

    Impella 5.5 with SmartAssist Set: Potential Device Interaction During Coronary Interventions

    Abiomed is updating labeling for Impella 5.5 with SmartAssist Set due to a potential device interaction with Shockwave Coronary IVL Catheter during coronary interventions. The product labeling currently lacks information about this potential interaction.

    Product
    Impella 5.5 with SmartAssist Set, EU; Product Code: 0550-0002;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2954-2024·2024-09-11

    Impella CP Smart Assist Set: Device interaction safety labeling update

    Abiomed is updating labeling for the Impella CP Smart Assist Set to address a potential device interaction with the Shockwave Coronary IVL Catheter during coronary procedures. No illnesses or injuries have been reported.

    Product
    Impella CP Smart Assist Set, EU; Product Code: 0048-0014;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2962-2024·2024-09-11

    Impella 5.5 Cardiac Pump Labeling Updated for Device Interaction Risk

    Abiomed is updating documentation for the Impella 5.5 cardiac pump to address a potential device interaction with the Shockwave Coronary IVL Catheter during coronary procedures. The notice affects 21 units distributed worldwide.

    Product
    Impella 5.5 with SmartAssist Set, CA; Product Code: 0550-0004;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2959-2024·2024-09-11

    Abiomed Impella Pump Recall for Potential Shockwave Catheter Interaction

    Abiomed is recalling 43,636 Impella Pumps to update instructions for use regarding a potential interaction with Shockwave Coronary IVL Catheters.

    Product
    Pump 371 14F LT CMR Set; Product Code: 0048-0045;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2963-2024·2024-09-11

    Abiomed Impella 5.5 Recall for Potential Shockwave Catheter Interaction

    Abiomed is recalling 2,916 Impella 5.5 units to update labeling regarding a potential interaction with Shockwave Coronary IVL Catheters during coronary interventions.

    Product
    Impella 5.5 with SmartAssist Set, US; Product Code: 0550-0008;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2953-2024·2024-09-11

    Philips Azurion 7M20 Fluoroscopic X-Ray System FlexArm Movement Recall

    Philips Azurion 7M20 interventional fluoroscopic X-ray systems with FlexArm ceiling-mounted stands may experience inconsistent or unavailable longitudinal movement due to bearing grease leakage affecting device mobility. Approximately 927 systems worldwide are affected.

    Product
    Philips Azurion 7M20 systems with FlexArm ceiling-mounted system, Interventional Fluoroscopic X-Ray System, Model Numbers 722079 and 722224
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2967-2024·2024-09-11

    Impella CP Smart Assist Set Recalled for Device Interaction Labeling Update

    Abiomed is updating labeling for ImpellaCP SmartAssistSetAPAC to address a potential interaction with Shockwave Coronary IVL Catheters during coronary interventions. Eight units were distributed worldwide.

    Product
    ImpellaCP SmartAssistSetAPAC, Delo1895; Product Code: 1000302;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2960-2024·2024-09-11

    Impella CP Cardiac Assist Pump Lacks Shockwave Catheter Interaction Warning

    Abiomed is updating labeling for Impella CP Smart Assist pumps to address a potential interaction with Shockwave Coronary IVL Catheters during coronary interventions. The interaction was previously undocumented in device labeling.

    Product
    Impella CP Smart Assist Set APAC; Product Code: 0048-0047;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2969-2024·2024-09-11

    Impella CP Smart Assist Set: Potential Device Interaction with Coronary Catheter

    Abiomed is updating labeling for the Impella CP Smart Assist Set to address a potential device interaction with the Shockwave Coronary IVL Catheter during coronary procedures.

    Product
    Impella CP Smart Assist Set; Product Code: 1000402;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2971-2024·2024-09-11

    Impella 5.5 Cardiac Pump Recalled for Undocumented Device Interaction

    Abiomed recalled 413 units of Impella 5.5 with SmartAssist S2 pumps worldwide due to a potential undocumented interaction with Shockwave coronary catheters during cardiac procedures. The company will update product labeling to disclose this interaction.

    Product
    Impella 5.5 with SmartAssist S2 Set, EU; Product Code: 1000482;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2957-2024·2024-09-11

    Abiomed updates Impella CP labeling for Shockwave coronary catheter interaction

    Abiomed is recalling the Impella CP Pump 371 Set due to a potential device interaction with the Shockwave Coronary IVL Catheter. The manufacturer is updating labeling to address this interaction. No illnesses or injuries have been reported.

    Product
    Impella CP Pump 371 Set, Clinical Trial; Product Code: 0048-0040;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V666000·2024-09-10

    Thor Motor Coach Recalls 2024 Motorhomes Due to Overheating Propane Tank Risk

    Thor Motor Coach is recalling 2024 Palladium and Talavera motorhomes because the liquid propane tank is located too close to the chassis exhaust, creating a fire risk.

    Product
    THOR MOTOR COACH — THOR MOTOR COACH TALAVERA, PALLADIUM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V668000·2024-09-10

    Freightliner and Western Star brake lights may fail during emergency braking

    Daimler Trucks is recalling certain Freightliner and Western Star trucks because brake lights may fail to illuminate during automatic emergency braking, increasing crash risk. Dealers will update software at no cost.

    Product
    FREIGHTLINER — FREIGHTLINER, WESTERN STAR EM2, 57X, 47X, 108SD
    Category
    Vehicle
    Distribution
    Distributed nationwide