  • HighFDA (Drugs)·D-0389-2026·2026-03-11

    Sodium iodide I-131 oral solution recalled over particulate matter

    Radnostix is recalling one batch of Sodium Iodide I-131 Therapeutic Oral Solution because of the presence of particulate matter caused by production issues.

    Product
    SODIUM IODIDE I-131 — SODIUM IODIDE I-131 (SODIUM IODIDE I-131)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0356-2026·2026-03-11

    Teva metoprolol succinate 100 mg tablets failed dissolution specifications

    Teva Pharmaceuticals is recalling six lots of Metoprolol Succinate Extended-Release Tablets 100 mg after the product failed dissolution specifications.

    Product
    METOPROLOL SUCCINATE — METOPROLOL SUCCINATE (METOPROLOL SUCCINATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1485-2026·2026-03-11

    Aesculap MINOP trocar shafts may be longer than specified

    Aesculap is recalling MINOP Trocar 150 mm with 6.0 mm working channel, model FF399R, because of the potential for the trocar shaft to be too long.

    Product
    Brand Name: AESCULAP Product Name: MINOP TROCAR 150MM 4 WKING CHANNEL6.0MM Model/Catalog Number: FF399R Software Version: N/A Product Description: MINOP TROCAR 150MM 4 WKING CHANNEL6.0MM Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0357-2026·2026-03-11

    Teva metoprolol succinate 200 mg tablets failed dissolution specifications

    Teva Pharmaceuticals is recalling three lots of Metoprolol Succinate Extended-Release Tablets 200 mg after the product failed dissolution specifications.

    Product
    METOPROLOL SUCCINATE — METOPROLOL SUCCINATE (METOPROLOL SUCCINATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0383-2026·2026-03-11

    Midodrine hydrochloride tablets recalled over inadequately sealed blister packaging

    The Harvard Drug Group is recalling one lot of Midodrine Hydrochloride Tablets 5 mg because of a defective container with inadequately sealed blister packaging.

    Product
    MIDODRINE HYDROCHLORIDE — MIDODRINE HYDROCHLORIDE (MIDODRINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0365-2026·2026-03-11

    Medi-First antiseptic wipes recalled over manufacturing practice deviations

    Acme United Corporation is recalling Medi-First Antiseptic Wipes over current good manufacturing practice deviations.

    Product
    MEDI-FIRST ANTISEPTIC WIPES — MEDI-FIRST ANTISEPTIC WIPES (BENZALKONIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0367-2026·2026-03-11

    Med-Nap BZK antiseptic towelettes recalled over manufacturing practice deviations

    Acme United Corporation is recalling Med-Nap BZK Antiseptic Towelettes in bulk packs over current good manufacturing practice deviations.

    Product
    MED NAP BENZALKONIUM CHLORIDE ANTISEPTIC — MED NAP BENZALKONIUM CHLORIDE ANTISEPTIC (BENZALKONIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0362-2026·2026-03-11

    Bulk BZK antiseptic towelette brands recalled over manufacturing practice deviations

    Acme United Corporation is recalling BZK Antiseptic Towelettes sold under the Piedmont, Touchpoint, Wellstar Cobb and FSR names over current good manufacturing practice deviations.

    Product
    1) BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%) 5"x7" Piedmont Sanitizing Hand Wipes, 1,000 ea Bulk, Made in USA for: Food Service Resources, Flowery Branch, GA 30542, NDC 0924-7130-00. 2) BZK Antiseptic Towelettes (Benzalkonium Chloride 0.13%) 5" x 7" Touchpoint, 1
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1492-2026·2026-03-11

    Vascular grafts recalled after expiry dates were calculated from packaging

    Vascutek is recalling Gelsoft Plus and Gelweave vascular prostheses because they were labeled with an additional month of shelf life, expiry having been calculated from packaging rather than gel impregnation.

    Product
    Gelsoft Plus, REF: 635024PE, 631514PE, 631222PE, 633008PE, 633010PE, 633007PE, 636010PE, 632522PE, 633012PE, 635018PE, 631516PE, 636016PE, 631220PE, 631608PE, 631206PE, 631407P50E, 631508PE, 636008PE, 636006PE, 632518PE, 634008PE, 634006PE, 631218PE, 632211PE, 634007PE, 633006PE,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0370-2026·2026-03-11

    Med-Nap cleansing towelette bulk packs recalled over manufacturing deviations

    Acme United Corporation is recalling Med-Nap Cleansing Towelettes in bulk cases over current good manufacturing practice deviations.

    Product
    MED NAP CLEANSING TOWELETTE — MED NAP CLEANSING TOWELETTE (BENZALKONIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0368-2026·2026-03-11

    WipesPlus alcohol free BZK wipes recalled over manufacturing practice deviations

    Acme United Corporation is recalling Wipes Plus Hand Sanitizing Alcohol Free BZK Wipes over current good manufacturing practice deviations.

    Product
    Wipes Plus, Hand Sanitizing Alcohol Free BZK Wipes (Benzalkonium Chloride 0.13%), Manufactured for: CFS Brands DBA WipesPlus, 4711 E. Heiner Rd. Oklahoma City, OK 73331, NDC 67151-333-01.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0379-2026·2026-03-11

    Semaglutide compounding ingredient lot recalled over incomplete validation before distribution

    Harbin Jixianglong Biotech is recalling a further lot of Semaglutide for prescription compounding because process validation and bacterial endotoxin method validation were not completed before distribution.

    Product
    Semaglutide, For Rx compounding use only, packaged in a) 1g, NDC 84385-106-01; b) 5g, NDC 84385-106-02; c) 10g, NDC 84385-106-06; d) 25g, NDC 84385-106-03; d) 50g, NDC 84385-106-04 Manufacturer: Harbin Jixianglong Biotech Co., Ltd., North of Baoan Road, East of Changqing Street,
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0377-2026·2026-03-11

    Instant hand sanitizing wipes recalled over manufacturing practice deviations

    Acme United Corporation is recalling Children's Healthcare of Atlanta Instant Hand Sanitizing Wipes over current good manufacturing practice deviations.

    Product
    Children's Healthcare of Atlanta, Instant Hand Sanitizing Wipe(Benzalkonium Chloride 0.13%), 1000 per case, Made in USA for Food Service Resources, Flowery Branch, GA 30542, NDC 0924-7130-00
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0387-2026·2026-03-11

    Zone 2 lidocaine cream recalled because stability data does not support expiry

    HTO Nevada, trading as Kirkman, is recalling one lot of Maximum Zone 2 4% Lidocaine Cream because the stability data does not support the labeled expiry date.

    Product
    MAXIMUM, ZONE 2, 4% Lidocaine Cream, (Lidocaine 4% and Epinephrine 0.01%), 1 oz bottles, Distributed By: Dermal Source, Portland, OR 97232, NDC 80069-015.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0358-2026·2026-03-11

    First Aid Only BZK antiseptic wipes recalled over manufacturing deviations

    Acme United Corporation is recalling First Aid Only BZK Antiseptic Towelettes in 100-count packs over current good manufacturing practice deviations.

    Product
    FIRST AID ONLY BZK ANTISEPTIC — FIRST AID ONLY BZK ANTISEPTIC (BENZALKONIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0386-2026·2026-03-11

    Zone 1 lidocaine cream recalled because stability data does not support expiry

    HTO Nevada, trading as Kirkman, is recalling one lot of Maximum Zone 1 4% Lidocaine Cream because the stability data does not support the labeled expiry date.

    Product
    MAXIMUM, ZONE 1, 4% Lidocaine Cream, 1/2 oz bottles, Distributed By: Dermal Source, Portland, OR 97232, NDC 80069-014.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1486-2026·2026-03-11

    Datascope CS100 balloon pump manual recalled for outdated battery specifications

    Datascope is recalling the CS100 IABP running software version Q.01 because the battery runtime and cycle specifications in the device's Instructions for Use need to be updated.

    Product
    CS100 IABP. Software Version CS100 IABP Q.01.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0385-2026·2026-03-11

    Vasocaine lidocaine spray recalled because stability data does not support expiry

    HTO Nevada, trading as Kirkman, is recalling Five-Star Vasocaine Spray because the stability data does not support the labeled expiry date.

    Product
    FIVE-STAR, VASOCAINE Spray, (Lidocaine HCl 4%, Racepinephrine HCl 0.01%), 4oz bottles, Distributed By: Dermal Source, Portland, OR 97232, NDC 80069-016.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0366-2026·2026-03-11

    Med-Nap BZK antiseptic towelettes recalled over manufacturing practice deviations

    Acme United Corporation is recalling Med Nap BZK Antiseptic Towelettes in 100-count packs over current good manufacturing practice deviations.

    Product
    MED NAP BENZALKONIUM CHLORIDE ANTISEPTIC — MED NAP BENZALKONIUM CHLORIDE ANTISEPTIC (BENZALKONIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1487-2026·2026-03-11

    Datascope CS300 balloon pump manual recalled for outdated battery specifications

    Datascope is recalling the CS300 IABP running software version C.01 because the battery runtime and cycle specifications in the device's Instructions for Use need to be updated.

    Product
    CS300 IABP. Software Version CS300 IABP C.01.
    Category
    Medical Device
    Distribution
    Distributed nationwide