The Recall Desk

State

New Jersey product recalls

73,100 recalls have nationwide distribution and so reach New Jersey. 9,767 additional recalls listed New Jersey specifically in their distribution scope.

What the numbers show

Total
9,767
Critical
1,249
Severe
2,486
Most recent
2026-09-25

Of the 9,767 recalls naming New Jersey we have scored against our rubric, 1,249 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,486 (25%) are Severe.

These figures cover only the 9,767 recalls whose distribution notice names New Jersey specifically. The 73,100 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

10251–10275 of 82867

  • HighFDA (Devices)·Z-3213-2024·2024-10-02

    Cervical disc implant recalled due to foreign contamination during assembly

    Centinel Spine is recalling the Prodisc C SK cervical disc implant due to blue discoloration identified as foreign contamination on the inlay during assembly. The contamination was not fully evaluated in manufacturing validations.

    Product
    prodisc C SK, Total cervical disc replacement, Model/Catalog Number: PDSM5
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3201-2024·2024-10-02

    Philips MR 5300 MRI System Recalled for Loose Assembly Screws

    Philips is recalling 68 MR 5300 MRI diagnostic systems worldwide because loose screws in the RF carrier assembly could block equipment movement and delay patient diagnosis.

    Product
    MR 5300 - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3197-2024·2024-10-02

    MRI Device Ingenia Ambition S Screws May Loosen and Block Tabletop

    Assembly screws in Philips Ingenia Ambition S MRI systems may loosen and protrude, potentially blocking the patient tabletop and delaying diagnosis. Philips is recalling 64 affected units worldwide.

    Product
    Ingenia Ambition S - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782108 2) 781359 3) 782133
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3248-2024·2024-10-02

    Hologic Recalls Selenia Dimensions and 3Dimensions Breast Imaging Software

    Hologic is recalling Selenia Dimensions and 3Dimensions software due to a defect that may cause blurry images and potential misdiagnosis.

    Product
    Selenia Dimensions/ 3Dimensions-Digital breast tomosynthesis Software Version Dimensions 1.12.0 and 3Dimensions 2.3.0 system software as follows Model/Catalog Number: 1. ASY-16824 FMI UPGRADE KIT, DIMENSIONS 1.12.0.3 SYSTEM SOFTWARE UPGRADE FOR 1.11.1 SYSTEMS 2. ASY-16825 FMI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3236-2024·2024-10-02

    Neuro Vascular Medical Kit Recalled for Sterilization Assurance Failure

    American Contract Systems recalls the Neuro Vascular ANKV91A medical convenience kit due to inability to confirm sterilization. Affected units were distributed across MO, MN, MA, OH, and NE.

    Product
    Neuro Vascular, ANKV91A; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3203-2024·2024-10-02

    MRI Diagnostic Device Screws May Loosen, Block Tabletop

    Philips SmartPath to dStream 1.5T MRI devices may have loose assembly screws that could block the diagnostic tabletop and delay imaging. 32 units distributed worldwide.

    Product
    SmartPath to dStream for 1.5T - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782112; 2) 781260
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3298-2024·2024-10-02

    Origio Sperm Wash Medium Recalled for Low Sodium Pyruvate Concentration

    CooperSurgical is recalling Origio Sperm Wash Medium due to low sodium pyruvate concentration. The deficiency could compromise gamete development in assisted reproductive procedures.

    Product
    Origio Sperm Wash Medium Pack of Five 60ml bottles - Intended for washing of spermatozoa. Part Number: 84055060D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3247-2024·2024-10-02

    BD Phoenix diagnostic systems may misidentify E. coli in clinical samples

    The BD Phoenix 100 system may misidentify Escherichia coli in clinical samples, potentially leading to misdiagnosis and inappropriate patient treatment. Becton Dickinson is recalling 764 units distributed worldwide.

    Product
    BD Phoenix 100-Intended for the rapid identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria. The BD Phoenix System provides rapid results for most aerobic and facultative anaerobic Grampositive bacteria. Catalog Number: 448100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3240-2024·2024-10-02

    Surgical convenience kit sterilization assurance cannot be confirmed

    American Contract Systems is recalling the Essentia MAJ Laparotomy Std Pack because an equipment failure prevented confirmation of sterilization requirements for this medical convenience kit.

    Product
    Essentia MAJ Laparotomy Std Pack, ESLT53B; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3301-2024·2024-10-02

    Cardinal Health Recalls Salem Sump Stomach Tubes Due to Valve Breakage

    Cardinal Health is recalling Salem Sump Dual Lumen Stomach Tubes because the Anti-Reflux Valve may break due to improper use. Labeling changes were made to address the issue.

    Product
    (a) CardinalHealth Salem Sump Dual Lumen Stomach Tube, 12 Fr/Ch (4.0 mm) x 48 in. (122 cm), Model #8888264929, Sterile; (b) CardinalHealth Salem Sump Dual Lumen Stomach Tube, 14 Fr/Ch (4.7 mm) x 48 in. (122 cm), Model #8888264945, Sterile; (c) CardinalHealth Salem Sump Dua
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3294-2024·2024-10-02

    Boston Scientific Recalls Agile Esophageal Stent Systems Due to Catheter Tip Detachment

    Boston Scientific is recalling Agile Esophageal Stent Systems because the delivery catheter tip may detach. The recall affects 10 units distributed worldwide.

    Product
    AGILE ESO FC RMV 23MM X 10.1CM IN 18.5 F-Agile Esophageal Partially Covered (PC) and Fully Covered (FC) OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concu
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3281-2024·2024-10-02

    Boston Scientific Recalls WallFlex Esophageal Stents Due to Catheter Tip Detachment

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems because the delivery catheter tip may detach during use.

    Product
    WALLFLEX PC ESOPH STENT 18/23MM X 103MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3202-2024·2024-10-02

    Philips MR 7700 MRI Scanner Recall for Loose Screws

    Philips is recalling 7 MR 7700 MRI scanners because loose screws may block the tabletop, potentially delaying diagnosis or causing patient anxiety.

    Product
    MR 7700 -For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782120
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3288-2024·2024-10-02

    Boston Scientific Recalls Agile Esophageal Stent Systems Due to Catheter Detachment Risk

    Boston Scientific is recalling Agile Esophageal Stent Systems because the delivery catheter tip may detach. The recall affects 15 units distributed worldwide.

    Product
    AGILE ESO OTW PC 23MM X 10.1CM IN 18.5 F-Agile Esophageal Partially Covered (PC) and Fully Covered (FC) OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concu
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3230-2024·2024-10-02

    American Contract Systems Recalls Open Shoulder Medical Convenience Kits

    American Contract Systems is recalling 12 Open Shoulder medical convenience kits because a faulty chart recorder prevented verification of sterilization requirements.

    Product
    Open Shoulder, LWOS39L; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3269-2024·2024-10-02

    Boston Scientific Recalls WallFlex Esophageal Stent Systems Due to Catheter Tip Detachment

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems because the delivery catheter tip may detach. The recall covers 176 units distributed worldwide.

    Product
    WALLFLEX FC ESO STENT RMV 23X125MM- Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esoph
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3224-2024·2024-10-02

    Karl Storz Nephroscope Recall Due to Unapproved Reprocessing Instructions

    Karl Storz Endoscopy is recalling 5 nephroscopes because their instructions for use list reprocessing methods not reviewed or approved by the FDA.

    Product
    Karl Storz - Endoskope , REF: 27830KA, Nephroscope for MIP M, Rx only, CE 0123
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3204-2024·2024-10-02

    MRI Diagnostic Device Loose Screws May Block Patient Tabletop

    Philips SmartPath dStream MRI devices have loose screws in the RF carrier assembly that may interfere with the moving tabletop, potentially delaying diagnosis. Affected units should be inspected and repaired immediately.

    Product
    SmartPath to dStream for XR and 3.0T- For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782113; 2) 781270; 3) 782129
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V737000·2024-10-02

    2025 Chevrolet Equinox EV door strikers recalled for possible breakage

    General Motors is recalling 2025 Chevrolet Equinox EV vehicles (along with Blazer and Blazer EV models) because door strikers may not be properly heat-treated and could break, causing doors to open unexpectedly. All affected vehicles remain in dealerships.

    Product
    CHEVROLET — CHEVROLET BLAZER EV, EQUINOX EV, BLAZER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3216-2024·2024-10-02

    ACUSON Redwood Ultrasound Systems Recall for Software Unit Conversion Error

    Siemens ACUSON Redwood ultrasound systems may display measurements 10 times smaller than actual if operators change the software from factory defaults to milliliters per second or minute. This could lead to misdiagnosis and poor patient management.

    Product
    ACUSON Redwood 1.0 and 2.0 Diagnostic Ultrasound Systems, REF: 11503314, with software
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Devices)·Z-3275-2024·2024-10-02

    Boston Scientific Esophageal Stents Recalled for Catheter Tip Detachment Risk

    Boston Scientific is recalling WallFlex and Agile Esophageal Stent Systems due to potential delivery catheter tip detachment. The recall affects 231 units distributed worldwide.

    Product
    WALLFLEX ESOPHAGEAL FC 18/23-25MMX10CM- Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent e
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3237-2024·2024-10-02

    Medical Convenience Kit Recalled for Failed Sterilization Assurance Validation

    American Contract Systems, Inc. is recalling the Hand Pack AKHD97C medical convenience kit because an inoperable chart recorder caused humidity readings to fall outside specifications, preventing confirmation of sterilization assurance.

    Product
    Hand Pack, AKHD97C; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3267-2024·2024-10-02

    Boston Scientific esophageal stents recalled due to catheter tip detachment risk

    Boston Scientific is recalling Wallflex and Agile esophageal stent systems due to potential detachment of the delivery catheter tip during stent placement. These devices are used to maintain patency in esophageal strictures caused by malignant tumors or esophageal fistulas.

    Product
    WALLFLEX FC ESO STENT RMV 18X153MM-Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esopha
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3245-2024·2024-10-02

    FDA Recalls Surgical Instrument Handle That May Break During Use

    The FDA is recalling LINK Universal Handles due to risk of material failure when first used. The surgical instrument may break during surgery, compromising patient safety.

    Product
    LINK Universal Handle, with quick coupling, Stainless Steel, straight, Item Number 130-394/01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3226-2024·2024-10-02

    Medical Pacemaker Pack Recalled Due to Sterilization Assurance Failure

    American Contract Systems is recalling the PACEMAKER PACK (Lot 2405112) due to an inoperable chart recorder that prevented confirmation of sterilization requirements. Affected units were distributed in MO, MN, MA, OH, and NE.

    Product
    PACEMAKER PACK, SLCV01J; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide