  • HighFDA (Devices)·Z-0131-2025·2024-10-23

    Rolling Walker Backrest May Disengage During Position Changes Creating Fall Risk

    Nova Ortho-Med is recalling 1,585 MONARCH ROLLATOR RED units because the backrest may disengage from its holder when users adjust from a slouched to upright position, creating a fall hazard.

    Product
    Brand Name: NOVA ORTHO-MED INC. Product Name: MONARCH ROLLATOR RED Model/Catalog Number: 4329RD Product Description: ROLLING WALKER MOBILITY AID
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V792000·2024-10-23

    Mack trucks with Bendix EC80 units may lose safety system functions

    Mack is recalling certain 2020-2025 trucks with Bendix EC80 Advanced Electronic Control Units because electrical noise may cause the ECU to misprocess commands or stop working.

    Product
    MACK — MACK PINNACLE (PI/PN), ANTHEM (AN), GRANITE (GR), PIONEER PR (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0095-2025·2024-10-23

    Boston Scientific AVVIGO+ Imaging System Grid Overlay Display Error

    A software anomaly in the Boston Scientific AVVIGO+ Multi-Modality Guidance System causes an incorrect grid overlay display when used with certain catheters. The wrong overlay may lead to incorrect measurement references during imaging procedures.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO+ BRIDGE TO INTEGRATED KIT; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0101-2025·2024-10-23

    AVVIGO+ Medical Imaging System Grid Overlay Display Software Error

    Boston Scientific is recalling AVVIGO+ Multi-Modality Guidance Systems due to a software anomaly that displays a 9-grid overlay instead of the correct 15-grid overlay during Live and Record modes. This incorrect display could affect imaging measurements during procedures.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM - ZERO COST EU + RO; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalitie
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0036-2025·2024-10-23

    Wilson-Cook Medical Recalls Hemo-7 and Hemo-10 Hemospray Endoscopic Hemostats

    Wilson-Cook Medical is recalling specific lots of Hemo-7 and Hemo-10 Hemospray Endoscopic Hemostats because they were manufactured with nonconforming raw materials.

    Product
    Cook Medical Hemo-7 Hemospray Endoscopic Hemostat, REF G56572, 2.8 mm, Sterile; and Hemo-10 Hemospray Endoscopic Hemostat, REF G21049, 3.7 mm, Sterile. The device is used for hemostasis of nonvariceal gastrointestinal bleeding.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0116-2025·2024-10-23

    Boston Scientific Recalls AVVIGO+ Guidance Systems Due to Software Display Error

    Boston Scientific is recalling 40 AVVIGO+ Multi-Modality Guidance Systems because a software anomaly causes an incorrect grid overlay to display during Live or Record mode when used with specific catheters.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO II TO AVVIGO MOB UPGRADE US; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities whi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0098-2025·2024-10-23

    Boston Scientific Recalls AVVIGO+ Guidance System Due to Software Anomaly

    Boston Scientific is recalling 15 units of the AVVIGO+ Multi-Modality Guidance System because a software anomaly causes an incorrect grid overlay to display during Live or Record mode.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + INT SYSTEM EU + ROW; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which inc
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0103-2025·2024-10-23

    Boston Scientific Recalls AVVIGO+ Guidance System Due to Software Anomaly

    Boston Scientific is recalling 14 units of the AVVIGO+ Multi-Modality Guidance System due to a software anomaly that displays an incorrect grid overlay during Live or Record mode.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM - ZERO COST US; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities whi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0115-2025·2024-10-23

    Boston Scientific Recalls AVVIGO+ Guidance System Due to Software Anomaly

    Boston Scientific is recalling 4 units of the AVVIGO+ Multi-Modality Guidance System because a software error displays the wrong grid overlay during Live or Record mode.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO II TO AVVIGO MOB UPGRADE JAPAN; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateNHTSA·24T012000·2024-10-23

    Michelin Recalls Specialty Tires Missing DOT Certification Markings

    Michelin is recalling certain XVS and TRX specialty tires provided as replacements for a prior recall because they lack the required DOT certification symbol on the sidewalls.

    Product
    TIRES:MARKINGS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0124-2025·2024-10-23

    Medline Open Heart Kits Recalled Due to Incorrect Cannula Labeling

    Medline Industries is recalling 22 Open Heart NIMC Kits because they contain Medtronic DLP Vessel Cannulae that were incorrectly labeled during manufacturing.

    Product
    MEDLINE OPEN HEART NIMC KIT, REF DYNJ908840
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0033-2025·2024-10-23

    Great Value Cherry Mixed Fruit Recalled for Undeclared Food Colorant

    Walmart is recalling Great Value Cherry Mixed Fruit cups nationwide because FD&C Red No 3 was not declared as an ingredient on the label.

    Product
    Great Value Cherry Mixed Fruit, 4 oz, 4 Count and 12 count plastic cups sealed with clear film.
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0109-2025·2024-10-23

    Boston Scientific AVVIGO+ Medical Device Grid Overlay Display Error

    Boston Scientific recalls 161 AVVIGO+ Multi-Modality Guidance Systems due to a software error causing an incorrect grid overlay display in Live and Record modes. The error affects measurement reference accuracy during intravascular imaging procedures.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM US; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which includes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0102-2025·2024-10-23

    Boston Scientific AVVIGO+ guidance system recalled for grid overlay display error

    Boston Scientific's AVVIGO+ guidance system is recalled because a software glitch causes an incorrect grid overlay display when used with an OptiCross 18 catheter. The correct overlay appears in Review mode, and no patient injuries have been reported.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM - ZERO COST JAPAN; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0120-2025·2024-10-23

    Medline Heart Overhead Table Pack recalled for incorrect model labeling

    Medline Industries recalls Heart Overhead Table Packs due to incorrect labeling. Some kits were marked as model 30000 when they should be model 30001.

    Product
    MEDLINE HEART OVERHEAD TABLE PACK, REF DYNJ0778508J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0123-2025·2024-10-23

    Medical Device Kit Incorrectly Labeled With Wrong Model Number

    Medline Industries recalls MEDLINE KIT CV I II vessel cannulae kits because product for model 30001 was incorrectly labeled as model 30000 during manufacturing.

    Product
    MEDLINE KIT CV I II, REF DYNJ906071B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0107-2025·2024-10-23

    Boston Scientific AVVIGO+ Guidance System Grid Mark Overlay Defect

    Boston Scientific is recalling the AVVIGO+ Multi-Modality Guidance System due to a software defect that displays an incorrect 9-grid mark overlay instead of the correct 15-grid mark overlay when used with OptiCross 18 Peripheral Imaging Catheters in Live or Record mode.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO + MOB SYSTEM EVAL US; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities which incl
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0112-2025·2024-10-23

    Medical imaging system software defect causes incorrect grid overlay display

    Boston Scientific recalled the AVVIGO+ imaging guidance system due to a software defect that displays a 9-grid overlay instead of the correct 15-grid overlay when connected to OptiCross 18 catheters in Live or Record mode.

    Product
    Boston Scientific AVVIGO+ Multi-Modality Guidance System, AVVIGO II TO AVVIGO INT UPGRADE JAPAN; the system utilizes an interactive display to provide physicians with physiologic, intravascular and/or intracardiac anatomical information. The system can provide various modalities
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0032-2025·2024-10-23

    Great Value Mixed Fruits Variety Pack Recalled for Undeclared Food Dye

    Walmart is recalling Great Value Diced Peaches, Mandarin Segments, & Cherry Mixed Fruits Variety Pack because FD&C Red No. 3 was not declared on the label. The recall affects 511,164 units distributed nationwide.

    Product
    Great Value Diced Peaches, Mandarin Segments, & Cherry Mixed Fruits Variety Pack, 4 oz, 12 Pack
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V784000·2024-10-21

    Vermeer Recalls 2024-2025 VXT600 G2 Vacuum Vehicles Due to Weld Defects

    Vermeer is recalling 2024-2025 VXT600 G2 vacuum vehicles because undersized welds on lift supports may fail, allowing the tank door to open and creating a road hazard.

    Product
    VERMEER — VERMEER VXT600 G2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V785000·2024-10-21

    Triumph alternator harness wiring may short circuit and overheat

    Triumph is recalling certain 2022-2024 Bonneville and Scrambler motorcycles because the wiring between the alternator and main harness connector may short circuit and overheat.

    Product
    TRIUMPH — TRIUMPH STREET SCRAMBLER SANDSTOR, BONNEVILLE T120 BLACK, BONNEVILLE T100, BONNEVILLE T120
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V786000·2024-10-21

    Brinkley Model G solar panels may be wired to overload circuits

    Brinkley RV is recalling certain 2024-2025 Model G fifth wheel trailers because the solar panels may have been incorrectly wired, which can overload circuits and overheat wiring.

    Product
    BRINKLEY RV — BRINKLEY RV MODEL G
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V774000·2024-10-18

    Forest River Recalls 2023-2024 Riverstone Fifth Wheel Trailers for Fire Risk

    Forest River is recalling 2023-2024 Riverstone Fifth Wheel trailers because incorrectly connected solar panels may cause wiring to overheat and melt, increasing the risk of a fire.

    Product
    FOREST RIVER — FOREST RIVER RIVERSTONE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V781000·2024-10-18

    Motiv Recalls 2021-2024 E-450 School Buses Due to Wire Connection Issue

    Motiv Power Systems is recalling 2021-2024 E-450 school buses because a loose wire connection could cause a loss of drive power, increasing crash risk.

    Product
    MOTIV — MOTIV E-450 BEV CHASSIS SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V779000·2024-10-18

    ATC Recalls Car Hauler and Stacker Trailers Due to Tongue Cracking

    ATC is recalling 2013-2025 Car Hauler and 2017-2025 Stacker trailers because stress may crack the A-frame tongue, potentially separating it from the trailer.

    Product
    ATC — ATC CAR HAULER, STACKER
    Category
    Vehicle
    Distribution