16826–16850 of 83513

  • HighCPSC·23239·2023-07-06

    woom ORIGINAL Kids' Bicycles Recalled Due to Fall Hazard

    woom Bikes USA recalls about 84,000 woom ORIGINAL children's bicycles from model years 2018–2021. The stem and handlebar can detach, causing riders to lose control and fall.

    Product
    woom ORIGINAL Bicycles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·23772·2023-07-06

    Yamaha Model Year 2023 Golf Cars and PTVs Recalled for Crash and Death Hazards

    Yamaha is recalling about 11,000 Model Year 2023 Golf Cars, Personal Transportation Vehicles, and Umax models because the accelerator spring can become dislodged, preventing the accelerator pedal from returning to rest and posing crash, injury, and death hazards.

    Product
    Model Year 2023 Yamaha Golf Car, Personal Transportation Vehicles (PTV) and Umax
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateCPSC·23240·2023-07-06

    Husqvarna 300 Series Snow Blowers Recalled for Unexpected Drive Engagement

    Husqvarna is recalling about 2,700 Residential 300 Series Snow Blowers because the auger pulley bolt can loosen, causing the drive to unexpectedly engage and potentially collide with users. No injuries have been reported.

    Product
    Residential 300 Series Snow Blowers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1876-2023·2023-07-05

    Endotracheal Tube Connector Disconnection Recall — FDA Class I

    TELEFLEX endotracheal tubes (Murphy design) may have a disconnected 15mm connector. Approximately 12,382 affected units were distributed nationwide. Healthcare facilities should inspect tubes before use.

    Product
    Endotracheal Tube oral/nasal uncuffed/plain - Murphy, REF 100382050
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1893-2023·2023-07-05

    Teleflex Endotracheal Tubes Recalled Due to Connector Disconnection Risk

    Teleflex is recalling 18,620 endotracheal tubes due to reported disconnection of 15mm connectors. The tubes are used for oral and nasal intubation and were distributed nationwide.

    Product
    Endotracheal Tube oral/nasal Murphy Eye, High Volume, Low Pressure Cuff, REF 112082095
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-2000-2023·2023-07-05

    MEGADYNE MEGA SOFT Return Electrode Recalled for Burns During Surgical Procedures

    Megadyne Medical Products is recalling the MEGADYNE MEGA SOFT Universal Plus Dual Patient Return Electrode due to reported patient burns that occurred during electrosurgical procedures.

    Product
    MEGADYNE MEGA SOFT Universal Plus Dual Patient Return Electrode. used during electrosurgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1994-2023·2023-07-05

    MEGADYNE MEGA 2000 Patient Return Electrode Recalled Due to Patient Burns

    The FDA is recalling 21,100 units of the MEGADYNE MEGA 2000 Patient Return Electrode due to reports of patient burns during electrosurgical procedures. All units distributed nationwide are affected.

    Product
    MEGADYNE MEGA 2000 Patient Return Electrode. used during electrosurgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1841-2023·2023-07-05

    Slick Set Uncuffed Endotracheal Tube Connector Disconnection Recall

    Teleflex LLC is recalling approximately 10,650 units of Slick Set Uncuffed Endotracheal Tubes due to reports of 15mm connector disconnection from the tube.

    Product
    Slick Set Uncuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 170140
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1874-2023·2023-07-05

    Endotracheal Tube Recall Due to 15mm Connector Disconnection

    TELEFLEX is recalling endotracheal tubes due to reports of 15mm connector disconnection. Approximately 25,160 units were distributed nationwide.

    Product
    Endotracheal Tube oral/nasal uncuffed/plain - Murphy, REF 100382030
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1947-2023·2023-07-05

    Preformed AGT Endotracheal Tubes Recalled Due to Connector Disconnection

    Teleflex is recalling 25,520 Preformed AGT endotracheal tubes due to reports of 15mm connector disconnection. This is an FDA Class I recall affecting units distributed nationwide.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111780070
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1927-2023·2023-07-05

    Endotracheal Tubes Recalled for Connector Disconnection Risk

    Teleflex LLC is recalling 2,860 endotracheal tubes due to reports of 15mm connector disconnection. Affected tubes were distributed nationwide including Puerto Rico.

    Product
    Endotracheal Tube oral/nasal uncuffed/plain - Magill, REF 100380035
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1898-2023·2023-07-05

    RUSCHELIT Safety Clear Tracheal Tube 15mm Connector Disconnection Recall

    TELEFLEX is recalling RUSCHELIT Safety Clear Tracheal Tubes due to reported disconnection of the 15mm connector, affecting approximately 37,076 units distributed nationwide.

    Product
    RUSCHELIT Safety Clear Tracheal Tube, oral/nasal, Magill, REF 112480040
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1882-2023·2023-07-05

    TELEFLEX Endotracheal Tubes Recalled Due to Connector Disconnection Risk

    TELEFLEX is recalling 760 endotracheal tubes due to reports of 15mm connector disconnection. This medical device failure could compromise airway management during critical care.

    Product
    Endotracheal Tube oral/nasal Magill, High Volume, Low Pressure Cuff, REF 112080095
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1890-2023·2023-07-05

    Teleflex endotracheal tubes recalled for connector disconnection defect

    Teleflex LLC is recalling 170,179 endotracheal tubes nationwide due to reports of 15mm connector disconnection. The tubes are used for airway management in medical facilities.

    Product
    Endotracheal Tube oral/nasal Murphy Eye, High Volume, Low Pressure Cuff, REF 112082080
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1999-2023·2023-07-05

    MEGADYNE MEGA SOFT Universal Plus Patient Return Electrode Recalled for Patient Burns

    Megadyne Medical Products is recalling 21,100 units of MEGA SOFT Universal Plus Patient Return Electrodes used in electrosurgery. The FDA Class I recall follows reports of patient burns during surgical procedures.

    Product
    MEGADYNE MEGA SOFT Universal Plus Patient Return Electrode. used during electrosurgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1828-2023·2023-07-05

    Teleflex Slick Set endotracheal tubes recalled for connector disconnection

    Teleflex Slick Set endotracheal tubes (REF 170055) are being recalled by the FDA following reports of disconnection of the 15mm connector. This Class I recall affects approximately 3,530 units distributed nationwide.

    Product
    Slick Set Cuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 170055
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1866-2023·2023-07-05

    Endotracheal Tube Connector Disconnection Recall for Teleflex Preformed AGT Tubes

    Teleflex is recalling 3,309 Preformed AGT Oral Endotracheal Tubes due to reports of 15mm connector disconnection. This defect may compromise airway management during medical use.

    Product
    Preformed AGT Oral Endotracheal Tube uncuffed/plain - Murphy, REF 100180055
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1833-2023·2023-07-05

    Teleflex Slick Set Endotracheal Tube Connector Disconnection Recall

    Teleflex is recalling Slick Set Cuffed Endotracheal Tube and Stylet Sets due to reports of disconnection of the 15mm connector from the endotracheal tube. The affected units were distributed nationwide.

    Product
    Slick Set Cuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 170080
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1888-2023·2023-07-05

    Endotracheal Tubes Recalled Due to Connector Disconnection Risk

    TELEFLEX endotracheal tubes are being recalled due to reports of the 15mm connector disconnecting from the tube. The recall affects 860,472 units distributed nationwide, including Puerto Rico.

    Product
    Endotracheal Tube oral/nasal Murphy Eye, High Volume, Low Pressure Cuff, REF 112082070
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1955-2023·2023-07-05

    Preformed AGT Endotracheal Tubes Recalled for Connector Disconnection

    Teleflex is recalling 37,890 Preformed AGT endotracheal tubes due to reports of 15mm connector disconnection. The devices were distributed nationwide in the United States and Puerto Rico.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111781065
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1884-2023·2023-07-05

    Teleflex Endotracheal Tubes Recalled Due to Connector Disconnection

    Teleflex is recalling 47,520 endotracheal tubes due to reported 15mm connector disconnection. The FDA classified this as a Class I recall; disconnected tubes could compromise airway management.

    Product
    Endotracheal Tube oral/nasal Murphy Eye, High Volume, Low Pressure Cuff, REF 112082050
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1872-2023·2023-07-05

    Preformed AGT Endotracheal Tubes Recalled Nationwide for Connector Disconnection

    Teleflex recalls 53,216 Preformed AGT Endotracheal Tubes due to reported disconnection of the 15mm connector. Affected units were distributed nationwide including Puerto Rico.

    Product
    Preformed AGT Oral Endotracheal Tube uncuffed/plain - Murphy, REF 100181045
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1946-2023·2023-07-05

    Preformed AGT oral endotracheal tube connector disconnection recalled

    Teleflex LLC recalls 14,780 preformed AGT oral endotracheal tubes due to reports of 15mm connector disconnection. Units were distributed nationwide.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111780065
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1954-2023·2023-07-05

    Preformed AGT Endotracheal Tubes Recalled for Connector Disconnection Risk

    TELEFLEX is recalling approximately 43,571 units of Preformed AGT Oral Endotracheal Tubes due to reports of 15mm connector disconnection from the tube, affecting nationwide distribution including Puerto Rico.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111781060
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1859-2023·2023-07-05

    Flexi-Set Uncuffed Endotracheal Tube Sets recalled for connector disconnection

    Teleflex is recalling approximately 10,600 Flexi-Set Uncuffed Endotracheal Tube and Stylet Sets due to reports that the 15mm connector may disconnect from the tube during use.

    Product
    Flexi-Set Uncuffed Endotracheal Tube and Stylet Set, oral/nasal, REF 506550
    Category
    Medical Device
    Distribution
    Distributed nationwide