The Recall Desk

State

Montana product recalls

73,106 recalls have nationwide distribution and so reach Montana. 3,571 additional recalls listed Montana specifically in their distribution scope.

What the numbers show

Total
3,571
Critical
689
Severe
785
Most recent
2026-09-23

Of the 3,571 recalls naming Montana we have scored against our rubric, 689 (19%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 785 (22%) are Severe.

These figures cover only the 3,571 recalls whose distribution notice names Montana specifically. The 73,106 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

12276–12300 of 76677

  • HighFDA (Devices)·Z-1333-2024·2024-03-27

    Directional Laser Probe Recalled for Fiber Extension and Direction Failure

    D.O.R.C. recalls 78 directional laser probes with Alcon/Lumenis connectors due to difficulties extending, retracting, or directing the laser fiber. The Class II recall affects units distributed across multiple U.S. states and Puerto Rico.

    Product
    Directional Laser Probe with Alcon / Lumenis connector (27 gauge / 0.4 mm)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1303-2024·2024-03-27

    Access Total T4 thyroxine assay recalled for test imprecision

    Beckman Coulter recalls Access Total T4 thyroxine assay due to imprecision that may cause erroneous or delayed diagnostic results.

    Product
    Access Total T4, REF 33800, IVD, thyroxine reagent assay.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0392-2024·2024-03-27

    Morphine Sulfate Ampuls Recalled for Expired Filters in Cartons

    Hikma Pharmaceuticals is recalling Infumorph 200 (morphine sulfate) ampuls because the sterile filter in the carton has an earlier expiration date than the medication, potentially compromising sterility.

    Product
    INFUMORPH 200 — INFUMORPH 200 (MORPHINE SULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0390-2024·2024-03-27

    Nicardipine Hydrochloride Injection Recalled for Out-of-Specification Organic Impurities

    Eugia US LLC is recalling Nicardipine Hydrochloride Injection nationwide due to failed impurity specifications. The 335,940 affected vials contain organic impurities exceeding acceptable standards.

    Product
    NICARDIPINE HYDROCHLORIDE — NICARDIPINE HYDROCHLORIDE (NICARDIPINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1345-2024·2024-03-27

    MINI STICK MAX guidewire introducer defect may prevent sheath passage during procedures

    Angiodynamics is recalling MINI STICK MAX guidewire introducers (155 units) due to manufacturing defects in the sheath hub that may prevent guidewire passage.

    Product
    MINI STICK MAX 5F X 10 CM STD .018 SS/SS ECHO 1.6" PG- Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-774
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1329-2024·2024-03-27

    Hip Traction Boot Assembly Defect Could Cause Device Detachment

    Baxter Healthcare is recalling HDS Traction Boot II units due to incorrect assembly. The boot key socket locking ridge faces upward, preventing proper attachment to the traction system.

    Product
    HDS Traction Boot II, REF AR-6529-23, The Traction Boot is designed to position, support and/or distract the patient's foot for hip surgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1310-2024·2024-03-27

    ECMO heat exchanger module recalled due to water path restriction

    Mc3 Inc is recalling 188 Nautilus Smart ECMO modules nationwide due to potential water path restrictions in the heat exchanger that may cause inadequate heat transfer and risk of hypothermia during use.

    Product
    NautilusTM Smart ECMO Module with Balance Biosurface-used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Product Number: 48135, 48135E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1350-2024·2024-03-27

    Convatec EsteemBody Drainable Pouches Recalled for Filter Weld Defect

    ConvaTec is recalling specific lots of EsteemBody Soft Convex Drainable Pouches due to inconsistency in filter weld strength, affecting 6709 units distributed in the US and internationally.

    Product
    Convatec EsteemBody Soft Convex, Drainable Pouch, Product codes (REF): a) 423643, b) 423658, c) 423659, d) 423664, e) 423666, f) 423645, g) 423667, h) 423657, i) 423652, j) 423646, k) 423654, l) 423653, m) 423647, n) 423644, o) 423648, p) 423665, q) 423656, r) 423651, s)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1330-2024·2024-03-27

    Laparotomy Sponges recalled for incomplete sterilization and missing RF detection

    Covidien is recalling Situate Laparotomy Sponges because some packs may contain improperly sterilized units lacking required RF detection features. Non-sterile sponges could cause infection, tissue trauma, and sepsis during surgery.

    Product
    Situate Laparotomy Sponge, RF and X-ray Detectable, REF: L1818-04P01C-1
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1348-2024·2024-03-27

    Guidewire Introducer Sheath Recalled for Internal Lumen Voids

    Angiodynamics is recalling 39 units of MINI STICK MAX vascular guidewire introducers due to voids in the sheath hub that may prevent guidewire passage during surgery, potentially delaying the procedure.

    Product
    MINI STICK MAX 4F X 10CM STIFF .018 NI/TU ECHO 1.6" PG- Used for the percutaneous introduction of a guidewire into the vascular system. - Catalog Number: 45-781
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1314-2024·2024-03-27

    Abbott Point of Care Control Device Recalled Due to Temperature Storage Failure

    Abbott's i-STAT Level 1 control device is recalled because a refrigerator temperature excursion on January 8, 2024, could cause incorrect or delayed test results. The walk-in storage unit failed, causing temperatures to fall below the required range of 35.6-46.4°F.

    Product
    Abbott Point of Care Control Control i-STAT¿ Level 1 10 X 1.7 mL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1312-2024·2024-03-27

    Pregnancy Test Control Set Recalled for Temperature Excursion Risk

    McKesson recalls Abbott Rapid Dx pregnancy test control sets due to a refrigerator temperature excursion that could cause inaccurate or delayed test results.

    Product
    Abbott Rapid Dx N America LLC Reproductive Endocrinology Control Set McKesson Consult" Pregnancy (hCG) Testing Positive Level / Negative Level 2 X 4 mL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1321-2024·2024-03-27

    Preat Nobel RP Titanium Abutment Blank Recalled for Manufacturing Defect

    Preat Corp is recalling 561 units of RP Titanium Abutment Blanks due to a manufacturing defect where the screw seat location may be too high, resulting in shortened screw engagement into the implant.

    Product
    Preat Nobel Active/Conical-compatible RP Titanium Blank, REF 9000967
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1308-2024·2024-03-27

    Curaplex Nasal Intubation Kit with incompatible tube holder recalled

    Sarnova HC is recalling the Curaplex Nasal Intubation Kit because the endotracheal tube holder is incompatible with nasal intubation, preventing practitioners from securing the tube. The recall affects 550 units distributed nationwide.

    Product
    Curaplex Nasal Intubation Kit w/ 7mm Endotracheal Tube-To perform a nasal intubation to establish an airway in an emergency. Item Number: 023070S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1331-2024·2024-03-27

    Directional Laser Probe Recalled for Fiber Extension and Direction Difficulties

    D.O.R.C. Dutch Ophthalmic Research Center is recalling Directional Laser Probes for ophthalmic surgery due to difficulties extending, retracting, and directing the laser fiber. The recall affects 84 units distributed nationwide.

    Product
    Directional Laser Probe with Alcon / Lumenis connector (23 gauge / 0.6 mm)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1318-2024·2024-03-27

    TMINI Knee Instrument Array Guide May Bind During Surgical Drilling

    A precision component in Think Surgical's TMINI robotic knee system may bind due to insufficient clearance. The binding could occur during surgical drilling.

    Product
    Assembly, Array Guide TMINI, REF: 109101, part of the TMINI Knee Instrument Set, used with the TMINI Miniature Robotic System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1347-2024·2024-03-27

    Vascular guidewire introducer recalled for manufacturing defect causing procedural delays

    Angiodynamics recalls the MINI STICK MAX vascular guidewire introducer due to internal defects in the sheath hub that may prevent guidewire insertion during surgery, potentially requiring equipment exchange.

    Product
    MINI STICK MAX 5F X 15 CM STIFF .018 NI/TU NON-ECHO 2.75" PG-Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-776
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1341-2024·2024-03-27

    Angiodynamics Guidewire Introducer Recall Due to Manufacturing Defect

    Angiodynamics recalls approximately 5,840 guidewire introducers with manufacturing defects that may prevent proper guidewire insertion during vascular procedures. The defect could cause procedural delays requiring equipment exchange.

    Product
    MINI STICK MAX 5F X 10 CM STIFF .018 NI/TU ECHO 2.75" PG-Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-759
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1343-2024·2024-03-27

    Vascular Guidewire Introducer Sheath Recalled for Internal Hub Defect

    Angiodynamics recalls 130 MINI STICK MAX guidewire introducers due to hub voids that may prevent guidewire passage during vascular procedures. No injuries reported.

    Product
    MINI STICK MAX 5F X 10 CM STD .018 SS/SS NON-ECHO 2.75" PG- Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-765
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1304-2024·2024-03-27

    Siemens DCA HbA1c Reagent Kit Recalled for Inaccurate Test Results

    Siemens is recalling its DCA HbA1c Reagent Kit because the device displays falsely elevated readings without alerting the user. This could lead to incorrect patient management of glucose levels.

    Product
    DCA Systems HbA1c Reagent Kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1309-2024·2024-03-27

    Nautilus ECMO Oxygenator recalled due to heat exchanger water path restriction

    Mc3 Inc recalls Nautilus ECMO Oxygenator units due to heat exchanger water path restriction that degrades temperature control performance. Inadequate heat transfer may lead to hypothermia risk.

    Product
    NautilusTM ECMO Oxygenator with Balance Biosurface-used in extracorporeal life support procedures to oxygenate blood, remove carbon dioxide and regulate blood temperature. Product Number: (1) 48145; (2) 48145E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1319-2024·2024-03-27

    I.B.S. 6.5-C Compression Screw Batch Recalled for Dimensional Mix-Up

    A batch of I.B.S compression screws may have incorrect dimensions compared to their labels due to a batch mix-up. The 59 affected units were distributed nationwide in Tennessee.

    Product
    I.B.S¿ 6.5-C Compression screw - diam 6.5mm lg 75mm,Part Number S65 ST175
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1322-2024·2024-03-27

    Dental Implant Impression Coping Recalled for Manufacturing Defect

    Thommen Medical AG is recalling impression coping units because the internal canal depth was not manufactured according to specifications, preventing firm connection to the dental implant. The product was distributed in Ohio and Kentucky.

    Product
    impression coping, repositionable, short, screw-retained, PF 4.0
    Category
    Medical Device
    Distribution
    Distributed nationwide