The Recall Desk

State

Mississippi product recalls

20,304 recalls have nationwide distribution and so reach Mississippi. 0 additional recalls listed Mississippi specifically in their distribution scope.

About recalls in Mississippi

Most US product recalls have nationwide distribution — the manufacturer ships into every state and the recall sweeps the same way. We include those in this listing because they affect Mississippi consumers even though the source notice doesn’t name the state. State-specific recalls are usually for products with regional distribution (a regional dairy, a local store brand) or where the agency was able to narrow the affected shipments to specific destinations.

If you’re checking whether a recall affects your purchase, the recall detail page lists the exact production lot codes, UPCs, and best-by dates. Match those against your package — distribution scope is a starting filter, not the final answer.

10476–10500 of 20304

  • HighFDA (Devices)·Z-0828-2024·2024-02-07

    Obstetrical and Gynecological Surgical Kits Recalled for Sterilization Assessment Defects

    American Contract Systems is recalling 1,020 obstetrical and gynecological surgical kits because components were sterilized without documented assessment of their suitability to the process, potentially causing loss of functionality or drug efficacy.

    Product
    Custom procedural convenience kits and trays, Obstetrical & Gynecological use, labeled as: a) LOWER PELVIC PACK, kit number AGLP52L; b) OB/GYN DAVINCI PACK A RG BASIN, kit number HGOB98G; c) DAVINCI GYN PACK, kit number HHDV17; d) KIT, GYNE ROBOTIC, kit number MMGR44D;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0923-2024·2024-02-07

    Knee Replacement Component Recalled for Potential Material Oxidation

    Howmedica Osteonics is recalling PS Lipped Tibial Insert Assy knee replacement components manufactured with UHMWPE material older than 5 years due to potential oxidation affecting performance.

    Product
    PS LIPPED TIBIAL INSERT ASSY DURACON Intended for knee replacement Product Number: 6742-1-411
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0884-2024·2024-02-07

    Knee replacement bearing insert recalled due to material degradation risk

    Howmedica Osteonics Corp. is recalling Scorpio-Flex knee bearing inserts made with material over 5 years old that may develop oxidation affecting performance. Affected patients should contact their physician if they experience knee problems.

    Product
    Scorpio-Flex Ttl Kn P-S Tib Brg Insrt Asy- -Intended for knee replacement Part Number: 72-16-0908
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0910-2024·2024-02-07

    Knee Replacement Implant Components Recalled for Material Degradation Risk

    Howmedica Osteonics Corp. is recalling specific lots of knee replacement implant components manufactured with aged raw material. The UHMWPE material may experience oxidation that could affect its structural properties.

    Product
    LEFT SMALL-PCA MOD.REV.DUR.REV.INSERT Intended for knee replacement. Product Number: 6637-0-631
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0913-2024·2024-02-07

    Knee Replacement Device Recalled Due to Potential Material Oxidation

    Howmedica Osteonics Corp. is recalling certain knee replacement devices (product number 6637-0-931, lot 57403601) because raw material used in manufacturing may be over 5 years old, potentially causing elevated oxidation that affects device durability.

    Product
    RGT.LARGE-PCA MOD.REV.- DUR.REV.INSERT Intended for knee replacement. Product Number: 6637-0-931
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0833-2024·2024-02-07

    Orthopedic surgical kits recalled for unassessed external component sterilization

    American Contract Systems recalls 5,524 orthopedic surgical kits due to unassessed sterilization of external components that may lose functionality, drug efficacy, or have excess sterilization chemical residue.

    Product
    Custom procedural convenience kits and trays, Othopedic use, labeled as: a) HIP FRACTURE, kit number AHHF15C; b) HIP FRACTURE, kit number AHHF15D; c) Hand Pack, kit number BBHP10E; d) Lower Extremity, kit number BBLE40B; e) Custom Podiatry, kit number BOCP70J; f) ROB
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0835-2024·2024-02-07

    Philips Azurion X-ray System Software Issue Causes Restart and Imaging Loss

    Philips Azurion interventional x-ray systems may continuously restart due to a software issue, causing loss of imaging functionality and data. If this occurs during a procedure, the procedure may be delayed or aborted.

    Product
    Philips Azurion system, Interventional fluoroscopic x-ray system. System Product Name - Model Numbers Azurion 3M12 -722063, 722221; Azurion 3M15 - 722064, 722222; Azurion 5M12 - 722227; Azurion 5M20 - 722228; Azurion 7B12/12 - 722067, 722225; Azurion 7B20/15 - 722068, 722226;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0912-2024·2024-02-07

    Knee Replacement Implant Recalled Due to Potential Material Oxidation Risk

    Howmedica Osteonics Corp. is recalling certain knee replacement implants made with UHMWPE material over 5 years old that may have oxidized, potentially affecting implant performance.

    Product
    RGT.LARGE-PCA MOD.REV.- DUR.REV.INSERT Intended for knee replacement Product Number: 6637-0-928
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0935-2024·2024-02-07

    Olympus EZDilate Fixed Wire Balloon Device Recalled for Inflation and Deflation Failures

    Olympus recalls 1,008 EZDilate Fixed Wire Balloon devices nationwide due to malfunction during use. Reported failures include inflation and deflation problems, bursting, leaking, and foreign body events in patients.

    Product
    EZDilate Fixed Wire Balloon 11-12-13. Indicated for endoscopic dilation of strictures of the esophagus in adults and adolescents (>12 years). Model: BD-400P-1380
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0917-2024·2024-02-07

    Knee Replacement Tibial Inserts Recalled Due to Material Oxidation Risk

    Knee replacement tibial inserts from Howmedica may have elevated oxidation if manufactured with raw material over 5 years old, potentially affecting material properties.

    Product
    DURATION A-P LIPPED TIB.INSERT-DURAC Intended for knee replacement Product Number: 6642-1-911
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0274-2024·2024-02-07

    Lupin Pharmaceuticals Recalls Cefixime Suspension Over Failed Specifications

    Lupin Pharmaceuticals is recalling Cefixime for Oral Suspension 100mg/5mL (4,608 bottles) due to failed impurity and degradation specifications. The product was distributed nationwide.

    Product
    CEFIXIME — CEFIXIME (CEFIXIME)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0822-2024·2024-02-07

    Custom Surgical Procedure Kits Recalled for Improper Sterilization Assessment

    American Contract Systems is recalling 3,196 custom surgical procedure kits because sterilized components lacked documented suitability assessment. The components may have lost functionality or accumulated excessive sterilization residuals.

    Product
    Custom procedural convenience kits and trays, gastroenterological & urological, labeled as: a) LAP KIDNEY MODULE, kit number AGKD50L; b) ROBOTIC PROSTATE PACK - 264852, kit number ANPR34S; c) LAP CHOLE - 213388, kit number BFLC02AD; d) GENERAL LAPAROSCOPY PACK, kit numbe
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0820-2024·2024-02-07

    Custom Ear, Nose and Throat Surgical Kits Recalled Due to Sterilization Validation Failure

    American Contract Systems is recalling 804 custom ear, nose and throat surgical kits nationwide because components were sterilized without validation that they could tolerate the process, potentially affecting functionality or drug efficacy.

    Product
    Custom procedural convenience kits and trays, ear, nose & throat, labeled as: a) T AND A PACK AGH ASC, kit number AGTA48J; b) OPSC EAR PACK, kit number LLEO66; c) T AND A PACK, kit number MMTA41F
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0948-2024·2024-02-07

    Philips Achieva 3.0T MRI Coil Seal Adhesive May Fail, Risking Patient Injury

    The Quadrature Body Coil seal adhesive in Philips Achieva 3.0T MRI scanners may fail, creating sharp edges that can injure patients. All units with model numbers 781277, 781177, 781278, 781344, and 781345 are affected.

    Product
    Achieva 3.0T. Model. (REF) Numbers 781277, 781177, 781278, 781344, 781345.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0947-2024·2024-02-07

    Philips Achieva 1.5T MRI system recalled for defective coil seal

    Philips is recalling the Achieva 1.5T Initial MRI system due to a defective Quadrature Body Coil seal. The adhesive may fail and create sharp edges that could cut or abrade patients during scanning.

    Product
    Achieva 1.5T Initial system. Model (REF) Numbers 781178.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0286-2024·2024-02-07

    OralProCare Medicated Lip Treatment Recalled for Manufacturing Specification Deviations

    Den-Mat Holdings recalls OralProCare medicated lip treatment due to manufacturing quality control deviations that may affect product conformance to labeled specifications. No illnesses reported.

    Product
    OralProCare medicated lip treatment, Net Wt 9.9 g (0.35 oz) tube, Ethyl alcohol 6.0% Antibacterial, Manufactured by: Den-Mat Holdings, LLC, Lompoc, CA, 93436, USA, NDC 59883-500-01, UPC: 3 59883 00000 4.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0952-2024·2024-02-07

    Philips MRI Scanner Quadrature Coil Seal Adhesive May Fail and Create Sharp Edges

    Philips Intera 1.5T Achieva Nova MRI machines (Model 781172) may develop seal adhesive failure in the Quadrature Body Coil, creating sharp edges that could injure patients during scanning.

    Product
    Intera 1.5T Achieva Nova. Model (REF) Numbers 781172.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0892-2024·2024-02-07

    Knee Replacement Component Recalled Due to Potential Material Degradation

    Howmedica Osteonics Corp. is recalling SCORPIO Total Knee Concentric Dome Patellas manufactured with raw material over 5 years old, which may have elevated oxidation levels affecting material properties.

    Product
    SCORPIO TOTAL KNEE CONCENTRIC DOME PATELLA-SZ #9 -Intended for knee replacement Part Number: 73-2910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0880-2024·2024-02-07

    Knee Replacement Implant Recalled for Potential Material Degradation Risk

    Howmedica Osteonics Corp. is recalling SCORPIO TS TIB knee replacement implants manufactured with aged raw material that may develop oxidation, potentially affecting performance.

    Product
    SCORPIO TS TIB INSERT. Intended for knee replacement Part Number: 72-4-7518
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0817-2024·2024-02-07

    Custom Cardiac Procedural Kits Recalled for Inadequate Sterilization Assessment

    American Contract Systems is recalling 4394 custom cardiac procedural kits due to components added without proper assessment for sterilization exposure, which may result in loss of functionality or drug efficacy.

    Product
    Custom procedural convenience kits and trays, cardiac, labeled as: a) HEART CATHETERIZATION TRAY, kit number JRHC45G; b) TAVR PACK, kit number LLTV10; c) CATH PED LF SJH, kit number SJCA21F; d) CATH HEART ADL LF SJH, kit number SJCH22F; e) INT RAD PORTS-LF - 206060, ki
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0816-2024·2024-02-07

    Custom Anesthesia Kits Recalled Over Sterilization Validation Failure

    American Contract Systems recalls 182 anesthesia procedure kits due to improper sterilization assessment of added components. The kits may have compromised functionality, reduced drug efficacy, or elevated sterilant residue.

    Product
    Custom procedural convenience kits and trays, anesthesia, labeled as: a) HEART ANESTHESIA BUNDLE NS, Kit Number LMHA01V; b) OR/Anesthesia Central Line Insertion Kit, Kit Number UIAN43L
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0894-2024·2024-02-07

    SCORPIO U-Dome Patella Knee Implant Recalled Due to Material Degradation Risk

    Howmedica Osteonics has recalled certain SCORPIO U-Dome Patella knee implants due to potential material oxidation in units manufactured with raw material over 5 years old. The oxidation may affect the implant's material properties.

    Product
    SCORPIO U-DOME PATELLA -Intended for knee replacement Part Number: 73-3308
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0879-2024·2024-02-07

    Knee Replacement Insert Recalled Due to Potential Material Oxidation

    Howmedica Osteonics recalls SCORPIO TS TIB INSERT knee replacement components manufactured with UHMWPE raw material over 5 years old, which may experience elevated oxidation affecting material properties. No injuries or illnesses have been reported.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacment Part Number: 72-4-7516
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0901-2024·2024-02-07

    Knee replacement poly insert recalled due to material oxidation risk

    Howmedica Osteonics recalled TRIDENT knee replacement poly inserts (Part 620-00-28J, Lot 38059601) due to potential UHMWPE material oxidation in components over 5 years old. Oxidation may affect material properties.

    Product
    HOWMEDICA OSTEONICS TRIDENT 0 deg POLY INSERT Intended for knee replacement Part Number: 620-00-28J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0950-2024·2024-02-07

    Philips Ingenia MRI Scanner Body Coil Seal Adhesive May Fail

    Philips is recalling Ingenia 1.5T CX MRI scanners because the Quadrature Body Coil seal adhesive may fail, creating sharp edges that could injure patients. Model numbers 781262 and 781261 are affected.

    Product
    Ingenia 1.5T CX. Model (REF) Numbers 781262, 781261.
    Category
    Medical Device
    Distribution
    Distributed nationwide