The Recall Desk

State

Mississippi product recalls

73,100 recalls have nationwide distribution and so reach Mississippi. 5,377 additional recalls listed Mississippi specifically in their distribution scope.

What the numbers show

Total
5,377
Critical
933
Severe
1,138
Most recent
2026-09-23

Of the 5,377 recalls naming Mississippi we have scored against our rubric, 933 (17%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,138 (21%) are Severe.

These figures cover only the 5,377 recalls whose distribution notice names Mississippi specifically. The 73,100 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

9826–9850 of 78477

  • HighFDA (Devices)·Z-3244-2024·2024-10-02

    Pacemaker COPM11B Medical Kits Recalled for Sterilization Verification Issue

    American Contract Systems is recalling 3 units of the COPM11B pacemaker medical kits due to inability to confirm sterilization requirements were met. An inoperable chart recorder caused humidity readings to exceed specifications during manufacturing.

    Product
    Pacemaker, COPM11B; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3266-2024·2024-10-02

    WallFlex and Agile Esophageal Stent Systems Recalled for Catheter Tip Detachment

    Boston Scientific recalls WallFlex and Agile Esophageal Stent Systems due to potential delivery catheter tip detachment. The affected stents treat esophageal strictures and may cause procedural complications if detachment occurs.

    Product
    WALLFLEX FC ESO STENT RMV 18X123MM-Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3248-2024·2024-10-02

    Hologic Recalls Selenia Dimensions and 3Dimensions Breast Imaging Software

    Hologic is recalling Selenia Dimensions and 3Dimensions software due to a defect that may cause blurry images and potential misdiagnosis.

    Product
    Selenia Dimensions/ 3Dimensions-Digital breast tomosynthesis Software Version Dimensions 1.12.0 and 3Dimensions 2.3.0 system software as follows Model/Catalog Number: 1. ASY-16824 FMI UPGRADE KIT, DIMENSIONS 1.12.0.3 SYSTEM SOFTWARE UPGRADE FOR 1.11.1 SYSTEMS 2. ASY-16825…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3234-2024·2024-10-02

    Medical Paracentesis Kit Recalled Over Sterilization Assurance Failure

    504 paracentesis kits (Lot 2405102) are being recalled because the manufacturer cannot confirm that sterilization requirements were met during production.

    Product
    Paracentesis Thoracente, SLPT76H; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0663-2024·2024-10-02

    Pyridoxine Injection Solution Recalled Due to Lack of Sterility Assurance

    Empower Pharmacy is recalling a pyridoxine (B6) injection solution because sterility assurance could not be confirmed. The recalled product is lot 609763 with a beyond-use date of 04/18/2025.

    Product
    Pyridoxine HCL (B6) Injection Solution, 100mg/mL, 30 mL Sterile Multiple-Dose Vial, For IM or IV use only, RX Only, Compounded by: Empower Pharmacy 5980 W Sam Houston Pkwy N Ste 300, Houston, TX 77041 NDC 72627-2424-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3243-2024·2024-10-02

    Medical device kit recalled due to inability to confirm sterilization assurance

    American Contract Systems recalled its Cysto medical convenience kit (36 units, Lot 2405033) due to a humidity monitoring failure that prevented confirmation of adequate product sterilization.

    Product
    Cysto, FTCY03L; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3191-2024·2024-10-02

    Custom Procedure Kit Sheath Introducers Mislabeled by Size

    Merit Medical Systems is recalling Custom Procedure Kits (REF: K12T-11077) with 7F sheath introducers that are incorrectly labeled as 7.5F, a labeling discrepancy affecting 24 units distributed nationwide.

    Product
    Custom Procedure Kit, REF: K12T-11077
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3251-2024·2024-10-02

    Cook Biotech Fistula Plug recalled for expiring before labeled date

    Cook Biotech is recalling 3 units of Biodesign Fistula Plug surgical implants because they expire before the printed expiration date. The devices were distributed worldwide.

    Product
    Biodesign Fistula Plug C-FPB-0.7 - For implantation to reinforce soft tissue for repair of recto-vaginal or anorectal fistulas. Order Number (GPN): G24668
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3259-2024·2024-10-02

    Biodesign Recto-Vaginal Fistula Plug units expire before labeled date

    Cook Biotech recalls Biodesign Recto-Vaginal Fistula Plug RVP-0.4 units because they expire before their labeled expiration dates. Affected lots were distributed worldwide.

    Product
    Biodesign Recto-Vaginal Fistula Plug RVP-0.4 - For implantation to reinforce soft tissue for repair of recto-vaginal fistulas. Order Number (GPN): G46602
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3195-2024·2024-10-02

    Philips Ingenia 3.0T MRI Scanner Tabletop Blockage Risk

    Philips is recalling 33 Ingenia 3.0T MRI scanners whose Integrated Radio Frequency Carrier assembly screws may come loose and block the horizontal tabletop, potentially causing diagnostic delays.

    Product
    Ingenia 3.0T - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782103
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3273-2024·2024-10-02

    Wallflex and Agile Esophageal Stent Systems Recalled Due to Catheter Tip Detachment Risk

    Boston Scientific is recalling the Wallflex Esophageal Stent System and Agile Esophageal Over the Wire Stent System due to potential delivery catheter tip detachment during placement. Wallflex devices totaling 115 units are affected.

    Product
    WALLFLEX FC ESO STENT RMV LL 23X125-Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3280-2024·2024-10-02

    FDA Recalls WallFlex Esophageal Stent Systems Due to Catheter Tip Detachment Risk

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems (516 units) due to potential for delivery catheter tip detachment during stent placement procedures.

    Product
    WALLFLEX ESOPHAGEAL FC 23/28MMX15CM-Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophageal…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3283-2024·2024-10-02

    Wallflex and Agile Esophageal Stent Systems Recalled for Potential Catheter Tip Detachment

    Boston Scientific is recalling WallFlex and Agile Esophageal Stent Systems due to the potential for delivery catheter tip detachment. The recall affects 39 units distributed worldwide.

    Product
    WALLFLEX PC ESOPH STENT 18/23MM X 153MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3198-2024·2024-10-02

    Philips Ingenia Ambition X MRI Scanner Recalled Due to Loose Screws

    Philips is recalling 63 units of the Ingenia Ambition X MRI scanner due to loose screws in the IRF carrier assembly that may block the imaging tabletop and potentially delay diagnosis.

    Product
    Ingenia Ambition X - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782109
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3279-2024·2024-10-02

    Boston Scientific esophageal stent systems recalled for catheter tip detachment

    Boston Scientific is recalling Wallflex and Agile esophageal stent systems due to potential delivery catheter tip detachment during stent placement procedures.

    Product
    WALLFLEX ESOPHAGEAL FC 23/28MMX12CM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophageal…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3281-2024·2024-10-02

    Boston Scientific Recalls WallFlex Esophageal Stents Due to Catheter Tip Detachment

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems because the delivery catheter tip may detach during use.

    Product
    WALLFLEX PC ESOPH STENT 18/23MM X 103MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3271-2024·2024-10-02

    WallFlex Esophageal Stent System Recalled for Potential Catheter Tip Detachment

    Boston Scientific Corporation is recalling WallFlex Esophageal Stent Systems and Agile Esophageal Over-the-Wire Stent Systems due to potential delivery catheter tip detachment during insertion procedures.

    Product
    WALLFLEX FC ESO STENT RMV LL 18X103- Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3296-2024·2024-10-02

    Origio Sperm Wash Medium Recalled Due to Low Sodium Pyruvate

    CooperSurgical is recalling Origio Sperm Wash Medium due to low sodium pyruvate concentration that could compromise sperm cell development. This affects 980 units distributed worldwide, including throughout the US.

    Product
    Origio Sperm Wash Medium Pack of Ten 10ml bottles - Intended for washing of spermatozoa Part Number: 84051010A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3287-2024·2024-10-02

    Esophageal Stent Systems Recalled for Potential Delivery Catheter Detachment

    Boston Scientific is recalling esophageal stent systems due to potential delivery catheter tip detachment during placement. Patients and providers with affected devices should contact the manufacturer for guidance.

    Product
    AGILE ESO OTW PC 23MM X 6.2CM IN 18.5 FR- Agile Esophageal Partially Covered (PC) and Fully Covered (FC) OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V737000·2024-10-02

    2025 Chevrolet Equinox EV door strikers recalled for possible breakage

    General Motors is recalling 2025 Chevrolet Equinox EV vehicles (along with Blazer and Blazer EV models) because door strikers may not be properly heat-treated and could break, causing doors to open unexpectedly. All affected vehicles remain in dealerships.

    Product
    CHEVROLET — CHEVROLET BLAZER EV, EQUINOX EV, BLAZER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1820-2024·2024-10-02

    Montreal Fudge Chocolate Fudge with Nuts Recalled for Mold Contamination

    Authentik Fudge is recalling Montreal Fudge brand Chocolate Fudge with Nuts due to potential mold contamination. The affected products were distributed through TJ Maxx and Marshalls locations.

    Product
    Montreal Fudge brand Chocolate Fudge with Nuts; 5.6oz
    Category
    Food
    Distribution
    40 states
  • HighFDA (Devices)·Z-3204-2024·2024-10-02

    MRI Diagnostic Device Loose Screws May Block Patient Tabletop

    Philips SmartPath dStream MRI devices have loose screws in the RF carrier assembly that may interfere with the moving tabletop, potentially delaying diagnosis. Affected units should be inspected and repaired immediately.

    Product
    SmartPath to dStream for XR and 3.0T- For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782113; 2) 781270; 3) 782129
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3222-2024·2024-10-02

    FDA Recalls Karl Storz Endoscopes Due to Unapproved Reprocessing Instructions

    Karl Storz is recalling 78 endoscopes because their instructions for use contain reprocessing modalities that have not been reviewed or approved by the FDA.

    Product
    Karl Storz - Endoskope , REF: 27294AA, Hopkins Telescope 6, 18 Fr, Rx only, CE 0123
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3250-2024·2024-10-02

    Cook Biotech Biodesign Fistula Plug implants recalled for premature expiration

    Cook Biotech is recalling Biodesign Fistula Plug C-FPB-0.4 implants because products expire before their printed expiration dates.

    Product
    Biodesign Fistula Plug C-FPB-0.4 - For implantation to reinforce soft tissue for repair of recto-vaginal or anorectal fistulas. Order Number (GPN): G24667
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3295-2024·2024-10-02

    Boston Scientific Agile Esophageal Stent Recall: Catheter Tip Detachment Risk

    Boston Scientific is recalling Agile Esophageal Stent Systems due to potential delivery catheter tip detachment. The Class II recall affects 6 units distributed worldwide.

    Product
    AGILE ESO FC RMV 23MM X 15.0CM IN 18.5 F- Agile Esophageal Partially Covered (PC) and Fully Covered (FC) OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of…
    Category
    Medical Device
    Distribution
    Distributed nationwide