The Recall Desk

State

Northern Mariana Islands product recalls

72,940 recalls have nationwide distribution and so reach Northern Mariana Islands. 22 additional recalls listed Northern Mariana Islands specifically in their distribution scope.

What the numbers show

Total
22
Critical
0
Severe
8
Most recent
2025-02-05

Of the 22 recalls naming Northern Mariana Islands we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 8 (36%) are Severe.

Which agencies issued them

These figures cover only the 22 recalls whose distribution notice names Northern Mariana Islands specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

3551–3575 of 72962

  • HighFDA (Devices)·Z-1099-2026·2026-01-21

    Circulatory support blood pumps recalled over locking into the motor

    Thoratec is recalling 8,399 CentriMag blood pump products after reports that the pump may not fit or lock securely into the motor using the screw-in locking feature.

    Product
    CentriMag Blood Pump, REF: 102953, 201-20003, 201-90010, 201-90016; CentriMag RVAD HDE KIT, REF: 104318; CentriMag Pre-connected Pack, REF: CMAEK00; CentriMag VAD KIT, REF: 201-51006, 201-51007, 201-90001 201-90001T; Blood Pump with CentriMag Acute Circulatory Support System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1018-2026·2026-01-21

    MRI systems recalled over ice that may block magnet venting

    Canon Medical Systems is recalling 22 Vantage Titan 3T MRI systems because ice in the magnet venting system could lead to a helium vessel rupture during a quench.

    Product
    VANTAGE TITAN 3T Model MRT-3010/MEXL-3010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V026000·2026-01-21

    Keystone Recalls Travel Trailers Due to Ramp Door Breakage Risk

    Keystone RV Company is recalling 2024-2026 Fuzion, Raptor, Redwood, and Voltage travel trailers because the ramp door may break away from the frame, increasing injury risk.

    Product
    KEYSTONE — KEYSTONE VOLTAGE, REDWOOD, RAPTOR, FUZION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0284-2026·2026-01-21

    Heparin antibody test kits recalled over a defect producing negative results

    Diagnostica Stago is recalling 438 Asserachrom HPIA kits from one lot because a potential defect can affect every well in an impacted strip and produce negative results.

    Product
    LUCKY ICE, Cool Mouthwash, Alcohol Free, 16.9oz, 12CT, UPC: 808829108989
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1096-2026·2026-01-21

    Surgical access port kits recalled over trays that may crack

    Intuitive Surgical is recalling 41,526 da Vinci SP Access Port Kits because the Access Port System tray may develop cracks, potentially resulting in a sterility breach.

    Product
    da Vinci SP, SP Access Port Kit, Large Incision Reference Numbers:430073 (2.7-4cm,SP1098, Box) & 430075 (2.7-7cm,SP1098,Box)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1098-2026·2026-01-21

    Venous stents recalled over a nitinol anomaly that reduces deployed diameter

    Medtronic is recalling 442 Abre Venous Self-Expanding Stent Systems because a nitinol anomaly causes a reduced stent diameter and radial force when deployed, which may result in migration.

    Product
    Abre Venous Self-Expanding Stent System, Model numbers AB9G14120090 AB9G12100090 AB9G14080090 AB9G12080090 AB9U12060090 AB9U14100090 AB9U14080090 AB9U12080090 AB9U14060090 AB9G14100090 AB9G12060090
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1071-2026·2026-01-21

    MRI systems recalled over ice that may block the magnet venting system

    Canon Medical Systems is recalling 34 Vantage Galan 3T MRI systems because ice may form in the venting system, and a quench in that condition could rupture the helium vessel.

    Product
    Allura Xper FD20 Biplane; Model Number: 722013;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0277-2026·2026-01-21

    Tylenol products recalled over insanitary conditions at a distribution center

    Gold Star Distribution is recalling Tylenol over CGMP deviations, citing insanitary conditions including rodent exposure and activity at its distribution center.

    Product
    TYLENOL a) 500 MG., 2'S DISPLAY, 50CT; b) COLD & FLU, 25CT/2S; c) COLD & FLU SEVERE, 2PK, 50CT; d) PM, 50CT; e) SINUS SEVERE, 2PK, 50CT
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0272-2026·2026-01-21

    Liquid NyQuil recalled over insanitary conditions at a distribution center

    Gold Star Distribution is recalling Liquid NyQuil over CGMP deviations, citing insanitary conditions including rodent exposure and activity at its distribution center.

    Product
    LIQUID NYQUIL a) regular, 12/8oz; b) cherry, 12/8oz
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1094-2026·2026-01-21

    Infusion pumps recalled over speakers that may not produce audible alarms

    ICU Medical is recalling 423 Plum Duo Infusion Systems after one lot of defective primary speakers may fail to produce sound, so the pump may not produce audible alarms or alerts.

    Product
    Plum Duo Infusion System, List Number 40002-04-01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1084-2026·2026-01-21

    Lucky Ice mouthwash recalled over insanitary conditions at a distribution center

    Gold Star Distribution is recalling Lucky Ice Cool Mouthwash over CGMP deviations, citing insanitary conditions including rodent exposure and activity at its distribution center.

    Product
    Asserachrom HPIA. Model/Catalog Number: 00615. The Asserachrom HPIA kit is intended for the qualitative detection in plasma or serum of the anti-heparin-platelet factor 4 (PF4) antibodies generated during the type II heparin-induced thrombocytopenia (HIT type II) by ELISA.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1057-2026·2026-01-21

    Levothyroxine tablets recalled after a bottle held the wrong strength

    Alvogen is recalling a lot of Levothyroxine Sodium Tablets, 150mcg, after a pharmacy reported a single bottle containing 88 mcg tablets instead of 150 mcg tablets.

    Product
    Medline Kits containing B. Braun IV Administration Sets and Pump Administration Sets, labeled as: 1) PRE OP KIT, Medline kit SKU DYKS1093B; 2) PRE OP KIT, Medline kit SKU DYKS1124C; 3) PRE OP KIT, Medline kit SKU DYKS1128C; 4) PREOP KIT, Medline kit SKU DYKS1130B; 5) P
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0261-2026·2026-01-21

    Frozen raw shrimp recalled over elevated levels of chloramphenicol

    AZ Gems is recalling 1,099 cases of Member's Mark Jumbo Raw Shrimp over elevated levels of chloramphenicol.

    Product
    Advil a) Ibuprofen, Dispenser Pack, 2 tablet packets in box containing 50 individual packets, UPC: 305730154895; b) PM, Ibuprofen, Dispenser Pack, 2 Caplet packets in box containing 50 packets, UPC: 305730164559
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1058-2026·2026-01-21

    Children's NyQuil recalled over insanitary conditions at a distribution center

    Gold Star Distribution is recalling Children's NyQuil Cold & Flu over CGMP deviations, citing insanitary conditions including rodent exposure and activity at its distribution center.

    Product
    Medline Kits containing B. Braun IV Administration Sets and Pump Administration Sets, labeled as: 1) ADMIN KIT, Medline kit SKU DYKS1339B; 2) ADMIN KIT, Medline kit SKU DYKS1339C; 3) QCASC WELCOME KIT, Medline kit SKU DYKS1359B; 4) ADMISSION KIT, Medline kit SKU DYKS
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0279-2026·2026-01-21

    TUMS antacid tablets recalled over insanitary conditions at a distribution center

    Gold Star Distribution is recalling TUMS antacid tablets over CGMP deviations, citing insanitary conditions including rodent exposure and activity at its distribution center.

    Product
    TUMS a) Assorted, 12 Ct.; b) Extra Strength (EX) Assorted Berries, 12-count #1194A *05/27; c)Extra Strength (EX) Assorted Fruit, 12-count, #1194C *03/27
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1078-2026·2026-01-21

    Oncology information system recalled over a potential for overtreatment

    Elekta is recalling a MOSAIQ Oncology Information System with Particle Therapy License because a specific sequence can result in a partial treatment being delivered twice.

    Product
    MOSAIQ Oncology Information System with Particle Therapy License (License Kit 45700000000IQRO)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0286-2026·2026-01-21

    Deodorant products recalled over insanitary conditions at a distribution center

    Gold Star Distribution is recalling Deodorant products over CGMP deviations, citing insanitary conditions including rodent exposure and activity at its distribution center.

    Product
    Deodorant: a) Axe, Body Spray, Wild Spice, 6CT, 150ML, UPC: 600108736469; b) LUCKY MENS STICK DEODORANT, SPRING FRESH, 24CT, 2.5 OZ, UPC: 808829111668; c) LUCKY MENS STICK DEODORANT, FRESH COMFORT, 24CT, 1.6 OZ, UPC: 808829089103; d) LADY DEODORANT, CHERRY BLOSSOSM, 24CT, 1.8oz,
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1092-2026·2026-01-21

    Patient positioning systems recalled over stereotactic radiosurgery tolerance errors

    C-RAD Positioning is recalling 189 Catalyst and Catalyst+ systems because the system may indicate a patient as correctly positioned at the isocenter when it is outside tolerance.

    Product
    Brand Name: Catalyst+ Product Name: Catalyst, Catalyst+ Model/Catalog Number: SP001-0026, SP003-0002 Software Version: cSRS module in combination with cMotion module Product Description: GMDN: 40893 Patient positioning device, diagnostic imaging/radiotherapy, laser Component
    Category
    Medical Device
    Distribution
    Distributed nationwide