  • HighNHTSA·26V273000·2026-04-29

    Newmar Recalls 2026 Freedom Aire Motorhomes for Incorrect Weight Labels

    Newmar is recalling 2026 Freedom Aire motorhomes because the Cargo Carrying Capacity label may display an incorrect weight value, potentially allowing the vehicle to be overloaded.

    Product
    NEWMAR — NEWMAR FREEDOM AIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1860-2026·2026-04-29

    Soft-Vu Angiographic Catheter Angiodynamics Guidewire Passage Defect

    Angiodynamics is recalling Soft-Vu Angiographic Catheters (Berenstein, Non-Braided) due to a manufacturing defect that may prevent guidewires from passing through the catheter hub. The catheters were distributed worldwide including the US.

    Product
    Soft-Vu Angiographic Catheter, Berenstein, Non-Braided; SOFT-VU BER 4F X 65CM 038 NB 0SH; Catalog No.: 10714009; Product/UPN No.: H787107140095 (Box), H787107140090 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1907-2026·2026-04-29

    OER-ELITE Endoscope Reprocessor Connecting Tubes Lock Failure Recall

    Olympus Corporation of the Americas is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2119) due to potential premature failure of the Version 2 reprocessor connecting tube lock levers.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2119.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1912-2026·2026-04-29

    Arrow Percutaneous Sheath Introducer Catheter Recall Due to Adhesive Defect

    Arrow International is recalling 115 units of its percutaneous sheath introducer with 7.5–8 Fr catheter because the liquid adhesive was incorrectly manufactured by a supplier. The product is used for venous access and central circulation catheterization.

    Product
    PERCUTANEOUS SHEATH INTRODUCER with 7.5 - 8 Fr. Catheter REF ASK-09903-MGH3 UDI code: (01)10801902159127(17)270331(11)251203(10)33F25J0352 The Arrow¿ percutaneous sheath introducer permits venous access and catheter introduction to the central circulation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1915-2026·2026-04-29

    Arrowg+ard Blue Plus four-lumen CVC kits recalled over adhesive manufacturing

    Pressure Injectable Arrowg+ard Blue Plus Four-Lumen CVC Kits are being recalled after a supplier notified the firm that the liquid adhesive was incorrectly manufactured.

    Product
    Pressure Injectable Arrowg+ard Blue Plus¿ Four-Lumen CVC Kit REF ASK-45854-PUPM1 UDI code: (01)10801902159578(17)270531(11)251205(10)33F25M0011 The Arrowg+ard technology is intended to provide protection against catheter-related bloodstream infections (CRBSIs). It is not int
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1928-2026·2026-04-29

    Central Line Dressing Kit containing non-sterile alcohol prep pads recalled

    LSL Healthcare's Central Line Dressing Kit (Model 2717H) is being recalled because it contains Webcol Large Alcohol Prep Pads that were found to be non-sterile. The kits were distributed nationwide in Maryland, Illinois, and Minnesota.

    Product
    LSL Healthcare, Central Line Dressing Kit, Model/Catalog Number: 2717H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1874-2026·2026-04-29

    AccuVu Angiographic Catheter, Omni Flush, Non-Braided Defect Recall

    Angiodynamics recalls AccuVu Angiographic Catheters due to a manufacturing defect that may prevent guidewires from passing through the catheter hub. The affected devices were distributed worldwide.

    Product
    AccuVu Angiographic Catheter, Omni Flush, Non-Braided, With 21 R/O Markers; ACCU-VU OF 4F X 70CM 035 NB 6SH 21 R/O 1CM; Catalog No.: 13709704; Product/UPN No.: H787137097045 (Box), H787137097040 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1923-2026·2026-04-29

    Oxoid Agglutinating Sera Salmonella 9-0 Serotyping Classification Error

    Remel Europe Ltd. is recalling specific lots of Oxoid Agglutinating Sera, Salmonella 9-0 due to cross-reactivity that may misidentify Salmonella 9-O serotypes as 2-O serotypes in laboratory testing.

    Product
    Oxoid Agglutinating Sera, Salmonella 9-0 R30957301
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1913-2026·2026-04-29

    Arrow Epidural Catheter Kits Recalled Due to Adhesive Manufacturing Defect

    Arrow International is recalling FlexTip Plus Epidural Catheter and FlexBlock Continuous Peripheral Nerve Block Catheter Kits due to incorrect manufacturing of liquid adhesive. The recall affects 190 units distributed nationwide.

    Product
    FLEXTIP PLUS EPIDURAL CATHETER;FLEXBLOCK CONTINOUS PERIPHERAL NERVE BLOCK CATHETER KIT/SET REF ASK-05502-BSM UDI code: (01)10801902209853(17)270831(11)251210(10)33F25K0409 The Arrow Epidural Catheter kit permits access to the epidural space for administration of epidural ane
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1861-2026·2026-04-29

    Angiodynamics Soft-Vu Angiographic Catheter Cobra Non-Braided Recall

    Angiodynamics is recalling specific lots of Soft-Vu Angiographic Catheter, Cobra (2), Non-Braided devices due to a manufacturing defect that may prevent guidewire passage through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Cobra (2), Non-Braided; SOFT-VU CB2 4F X 65CM 038 NB 0SH; Catalog No.: 10714011; Product/UPN No.: H787107140115 (Box), H787107140110 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1864-2026·2026-04-29

    Soft-Vu Angiographic Catheter Cobra Non-Braided Manufacturing Defect

    Angiodynamics, Inc. recalls Soft-Vu Angiographic Catheter, Cobra (1), Non-Braided devices due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Cobra (1), Non-Braided; SOFT-VU CB1 4F X 100CM 038 NB 0SH; Catalog No.: 10714017; Product/UPN No.: H787107140175 (Box), H787107140170 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1906-2026·2026-04-29

    Olympus OER-ELITE Endoscope Reprocessor Connecting Tubes Recalled

    Olympus Corporation is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2118) due to potential premature failure of Version 2 reprocessor connecting tube lock levers. The recall affects 1,259 units distributed worldwide.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2118.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1904-2026·2026-04-29

    Olympus OER-ELITE Endoscope Reprocessor Connecting Tubes Recall

    Olympus Corporation of the Americas is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2116) because the Version 2 reprocessor connecting tube lock levers may fail prematurely.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2116.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1887-2026·2026-04-29

    Medline Convenience Kits with 10mL Syringes recalled for unapproved design changes

    Medline Industries is recalling Convenience Kits containing 10mL Polycarbonate Colored Syringes due to unapproved design changes made outside of FDA 510(k) clearance. The recall affects approximately 270,311 units distributed nationwide and internationally.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes EXTREMITY PACK DYNJ34846C HAND PACK DYNJ83218A, DYNJ85396 LAMINECTOMY DYNJ905156R MAJOR EXTREMITY DYNJ905159L, DYNJ905159M MAJOR EXTREMITY PACK DYNJ69926A PODIATRY PACK D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1919-2026·2026-04-29

    IV Administration Sets Potential Backflow and Occlusion Risk

    B. Braun is correcting gravity and pump administration sets used with specific infusion pumps due to risk of medication backflow from secondary containers into primary containers and occlusion during priming.

    Product
    Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14433
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1902-2026·2026-04-29

    OER-ELITE Endoscope Reprocessor Connecting Tubes Lock Lever Failure Risk

    Olympus is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2114) because the Version 2 reprocessor connecting tube lock levers may fail prematurely, potentially affecting equipment operation and patient safety during endoscope reprocessing.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2114.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1830-2026·2026-04-29

    Medline Namic Control Syringes recalled due to rescinded FDA clearance

    Medline Industries is recalling Medline Namic Control Syringes (Model DYNJSYR10CWRB) because the FDA has rescinded their 510(k) regulatory clearance. The recall affects 24,170 units distributed nationwide.

    Product
    Medline Namic Syringes: 1) SYR CNTRL 10ML RING W/ROT NB, Model Number: DYNJSYR10CWRB;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1918-2026·2026-04-29

    Rover Mobile X-ray System may malfunction and become inoperable

    Micro-X Ltd. is recalling certain Rover Mobile X-ray Systems (models MXU-RV35 and MXU-RV71) because the X-ray generator may malfunction, rendering the device inoperable.

    Product
    Rover Mobile X-ray System Model/Catalog Number: MXU-RV35 and MXU-RV71
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1921-2026·2026-04-29

    IV Administration Sets and Gravity Infusion Kits Risk Backflow

    Windstone Medical Packaging is recalling Custom Convenience Kits Pre Op Kits (Part Number AMS14994A) due to a potential for backflow of medication from secondary IV containers into primary IV containers. The recall affects 520 units distributed nationwide.

    Product
    Custom Convenience Kits Pre Op Kit - NS, Part Number AMS14994A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1909-2026·2026-04-29

    OER-ELITE Endoscope Reprocessor Connecting Tubes Lock Levers Failure Risk

    Olympus Corporation is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2330) because the Version 2 reprocessor connecting tube lock levers may fail prematurely.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2330.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1908-2026·2026-04-29

    Olympus OER-ELITE Endoscope Reprocessor Connecting Tubes Recall

    Olympus is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2138) due to potential premature failure of the Version 2 reprocessor connecting tube lock levers. The defect could affect proper tube attachment during endoscope reprocessing.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2138.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1897-2026·2026-04-29

    nanOss 3D Bone Graft Substitute Incorrectly Labeled with Five-Year Shelf Life

    XTANT Medical Holdings is recalling nanOss 3D Advanced Bone Graft Substitute products due to incorrect labeling showing a 5-year shelf life when the approved shelf life is four years.

    Product
    nanOss 3D Advanced Bone Graft Substitute nanOss 3D Plus Advanced Bone Graft Substitute 90-300-251008: nanOss 3D Advanced Bone Graft Substitute, 25x100x8mm, 20cc 90-300-25508: nanOss 3D Advanced Bone Graft Substitute, 25x50x8mm, 10cc 90-300-251004: nanOss 3D Advanced Bone Gr
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1925-2026·2026-04-29

    Flamingo Funnel Medium surgical device recall due to sterilization incompatibility

    SurgiSmoke Solutions is recalling certain lots of Flamingo Funnel Medium (Model SQ20012-02) because a non-gamma sterilization compatible drape was used during manufacturing, which could affect device safety.

    Product
    Flamingo Funnel Medium, Model Number SQ20012-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1847-2026·2026-04-29

    Medline Hysteroscopy and Sling Packs subject to regulatory rescission

    FDA has rescinded 510(k) regulatory clearances for certain Control Syringes, Guidewires, and High-Pressure Tubing components in two Medline medical device kits distributed nationwide.

    Product
    Medline Kits: 1) HYSTEROSCOPY PACK, Model Number: DYNJ48399C; 2) SLING PACK, Model Number: DYNJ62849B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0484-2026·2026-04-29

    Pantoprazole Sodium Tablets Recalled for Discoloration Issues

    Hetero Labs Limited is recalling Pantoprazole Sodium 40 mg delayed-release tablets due to discoloration—some tablets are darker than normal with lighter-colored spots. The firm received five complaints about the affected tablets.

    Product
    PANTOPRAZOLE SODIUM — PANTOPRAZOLE SODIUM (PANTOPRAZOLE)
    Category
    Drug
    Distribution
    Distributed nationwide