The Recall Desk

State

Maryland product recalls

73,096 recalls have nationwide distribution and so reach Maryland. 8,223 additional recalls listed Maryland specifically in their distribution scope.

What the numbers show

Total
8,223
Critical
996
Severe
2,134
Most recent
2026-09-25

Of the 8,223 recalls naming Maryland we have scored against our rubric, 996 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,134 (26%) are Severe.

These figures cover only the 8,223 recalls whose distribution notice names Maryland specifically. The 73,096 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

10276–10300 of 81319

  • HighFDA (Devices)·Z-3239-2024·2024-10-02

    Medical Cath Lab Pack Recalled Due to Sterilization Assurance Failure

    American Contract Systems is recalling Cath Lab Pack CECL02P medical kits because an inoperable chart recorder caused humidity readings to be out-of-specification, preventing confirmation that sterilization requirements were met.

    Product
    Cath Lab Pack, CECL02P; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3200-2024·2024-10-02

    MRI Scanner Loose Screws May Block Tabletop and Delay Diagnosis

    The Ingenia Elition X MRI device may have loose screws that interfere with the horizontal tabletop, potentially delaying patient diagnosis and causing anxiety during extended bore exposure.

    Product
    Ingenia Elition X- For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782151; 2) 782119; 3) 781358; 4) 782107; 5) 78213
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3229-2024·2024-10-02

    Arthroscopy Pack Recalled Due to Unconfirmed Sterilization Assurance

    American Contract Systems is recalling 48 Arthroscopy Packs because humidity readings were out of specification, preventing confirmation of sterilization.

    Product
    Arthroscopy Pack, MSKA45A; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3219-2024·2024-10-02

    Karl Storz Hopkins Telescope Recalled for Unapproved Reprocessing Instructions

    Karl Storz Hopkins Telescope 6 endoscopes are being recalled because the instructions for use contain reprocessing procedures not reviewed or approved by the FDA. Affected units should not be used until corrected instructions are provided.

    Product
    Karl Storz - Endoskope , REF: 27093AA Hopkins Telescope 6, Rx only, CE 0123
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3232-2024·2024-10-02

    Medical Device Kit Recall: Sterilization Assurance Cannot Be Confirmed

    American Contract Systems is recalling 60 Shoulder SESH18I medical convenience kits nationwide due to equipment failure that resulted in out-of-specification humidity readings, preventing sterilization assurance confirmation.

    Product
    Shoulder, SESH18I; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3215-2024·2024-10-02

    Siemens ACUSON Juniper ultrasound systems software unit conversion error

    Siemens is recalling ACUSON Juniper ultrasound systems that may perform incorrect unit conversions when configured with non-default settings, potentially producing measurements 10 times smaller than actual values and risking patient misdiagnosis.

    Product
    ACUSON Juniper 1.0, 1.5, 2.0, 2.5 Diagnostic Ultrasound Systems, REF: 11335791, with software. ACUSON Juniper Select 2.0, 2.5 Diagnostic Ultrasound Systems, REF: 11653093, with software.
    Category
    Medical Device
    Distribution
    42 states
  • HighFDA (Devices)·Z-3248-2024·2024-10-02

    Hologic Recalls Selenia Dimensions and 3Dimensions Breast Imaging Software

    Hologic is recalling Selenia Dimensions and 3Dimensions software due to a defect that may cause blurry images and potential misdiagnosis.

    Product
    Selenia Dimensions/ 3Dimensions-Digital breast tomosynthesis Software Version Dimensions 1.12.0 and 3Dimensions 2.3.0 system software as follows Model/Catalog Number: 1. ASY-16824 FMI UPGRADE KIT, DIMENSIONS 1.12.0.3 SYSTEM SOFTWARE UPGRADE FOR 1.11.1 SYSTEMS 2. ASY-16825 FMI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3277-2024·2024-10-02

    Boston Scientific Esophageal Stent Systems Recalled for Catheter Detachment Risk

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems due to potential delivery catheter tip detachment. The recall affects 79 units distributed worldwide.

    Product
    WALLFLEX ESOPHAGEAL FC 18/23-25MMX15CM- Agile Esophageal Partially Covered and Fully Covered OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3204-2024·2024-10-02

    MRI Diagnostic Device Loose Screws May Block Patient Tabletop

    Philips SmartPath dStream MRI devices have loose screws in the RF carrier assembly that may interfere with the moving tabletop, potentially delaying diagnosis. Affected units should be inspected and repaired immediately.

    Product
    SmartPath to dStream for XR and 3.0T- For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782113; 2) 781270; 3) 782129
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3243-2024·2024-10-02

    Medical device kit recalled due to inability to confirm sterilization assurance

    American Contract Systems recalled its Cysto medical convenience kit (36 units, Lot 2405033) due to a humidity monitoring failure that prevented confirmation of adequate product sterilization.

    Product
    Cysto, FTCY03L; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V737000·2024-10-02

    2025 Chevrolet Equinox EV door strikers recalled for possible breakage

    General Motors is recalling 2025 Chevrolet Equinox EV vehicles (along with Blazer and Blazer EV models) because door strikers may not be properly heat-treated and could break, causing doors to open unexpectedly. All affected vehicles remain in dealerships.

    Product
    CHEVROLET — CHEVROLET BLAZER EV, EQUINOX EV, BLAZER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3264-2024·2024-10-02

    Stryker TMJ Unilateral Implant Recalled Due to Incorrect Components

    TMJ Solutions Inc is recalling the Stryker TMJ Unilateral Implant because patient-fitted prostheses contained incorrect components. Patients should contact their healthcare provider immediately.

    Product
    Stryker TMJ Unilateral Implant, REF: GHG010, consisting of the following components: Ref: CHG010AM, Anatomical Bone Model, Accessory, REF: CHG010RF, Glenoid Fossa Component, Right, REF: CHG010RM, Mandibular Component, Right.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3194-2024·2024-10-02

    Philips Ingenia 1.5T MRI Device Recall: Loose Screws May Block Tabletop

    Philips recalls certain Ingenia 1.5T MRI devices due to loose assembly screws that may block the patient tabletop, potentially delaying diagnosis and causing patient anxiety.

    Product
    Ingenia 1.5T -For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782115 2) 782101 3) 782140
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3197-2024·2024-10-02

    MRI Device Ingenia Ambition S Screws May Loosen and Block Tabletop

    Assembly screws in Philips Ingenia Ambition S MRI systems may loosen and protrude, potentially blocking the patient tabletop and delaying diagnosis. Philips is recalling 64 affected units worldwide.

    Product
    Ingenia Ambition S - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782108 2) 781359 3) 782133
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3237-2024·2024-10-02

    Medical Convenience Kit Recalled for Failed Sterilization Assurance Validation

    American Contract Systems, Inc. is recalling the Hand Pack AKHD97C medical convenience kit because an inoperable chart recorder caused humidity readings to fall outside specifications, preventing confirmation of sterilization assurance.

    Product
    Hand Pack, AKHD97C; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3249-2024·2024-10-02

    IntelliVue Patient Monitors recalled for electrical grounding defect

    Philips is recalling approximately 545 IntelliVue Patient Monitor units with a broken ground bolt that may cause loss of electrical grounding, potentially affecting the device's electromagnetic immunity and emission.

    Product
    IntelliVue Patient Monitor MX400 (Model Number 866060), MX430 (Model Number 866061), MX450 (Model Number 866062), MX500 (Model Number 866064), and MX550 (Model Number 866066)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3192-2024·2024-10-02

    Biopsy instrument packaging holes compromise sterile barrier integrity

    Argon Medical Devices recalls BioPince Ultra and Tru-Core II biopsy instruments due to holes in packaging trays compromising the sterile barrier, which may allow microorganism introduction and infection risk.

    Product
    BioPince Ultra Full Core Biopsy Instrument: REF: REF: 360-1080-01, 360-1080-02, 360-1080-03, 360-1580-01, 360-1580-02, 360-1580-03, 360-2080-01, 360-2080-02, 360-2080-03, 370-1080-01, 370-1080-02, 370-1080-03, 370-1580-01, 370-1580-02, 370-1580-03; Tru-Core II Biopsy Instrument,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3228-2024·2024-10-02

    Endovascular AAA Pack recalled for sterilization assurance failure

    American Contract Systems recalls 360 units of Endovascular AAA Pack due to inability to confirm sterilization requirements were met. An inoperable chart recorder prevented verification that environmental conditions during sterilization met required specifications.

    Product
    Endovascular AAA Pack, ESED52B; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1824-2024·2024-10-02

    M&P Delicacies Pirozhki Pies Recalled for Undeclared Wheat and Milk

    M&P Delicacies Pirozhki (pies) are recalled due to undeclared wheat and milk in the product. Consumers with allergies to these ingredients should not consume the product.

    Product
    M&P Delicacies PIROZHKI (PIES) with Black Currant; INGREDIENTS: Flour, eggs, butter, vegetable oil, dry yeast, sugar, salt; Filling: Black currant, sugar, farina; 1 SERVING READY TO EAT; KEEP FROZEN
    Category
    Food
    Distribution
    7 states
  • HighFDA (Devices)·Z-3240-2024·2024-10-02

    Surgical convenience kit sterilization assurance cannot be confirmed

    American Contract Systems is recalling the Essentia MAJ Laparotomy Std Pack because an equipment failure prevented confirmation of sterilization requirements for this medical convenience kit.

    Product
    Essentia MAJ Laparotomy Std Pack, ESLT53B; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3270-2024·2024-10-02

    Wallflex and Agile Esophageal Stents Recalled for Catheter Tip Detachment Risk

    Boston Scientific recalls Wallflex FC and Agile Esophageal Stent Systems due to the potential for delivery catheter tip detachment during use. Approximately 145 units are affected worldwide.

    Product
    WALLFLEX FC ESO STENT RMV 23X155MM- Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esoph
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3284-2024·2024-10-02

    Esophageal Stent Systems Recalled Due to Catheter Detachment Risk

    Boston Scientific is recalling Wallflex and Agile esophageal stent systems worldwide due to the potential for delivery catheter tip detachment during placement. The recall affects 133 units distributed globally.

    Product
    WALLFLEX PC ESOPH STENT 23/28MM X 105MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3191-2024·2024-10-02

    Custom Procedure Kit Sheath Introducers Mislabeled by Size

    Merit Medical Systems is recalling Custom Procedure Kits (REF: K12T-11077) with 7F sheath introducers that are incorrectly labeled as 7.5F, a labeling discrepancy affecting 24 units distributed nationwide.

    Product
    Custom Procedure Kit, REF: K12T-11077
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1827-2024·2024-10-02

    Sour Cherry Vareniki Recalled for Undeclared Wheat Allergen

    M & P Food Productions is recalling Sour Cherry Vareniki frozen dumplings due to undeclared wheat, a major allergen not listed on the label.

    Product
    Sour Cherry Vareniki; M&P Food Production; NET WT. 14oz; HANDMADE; Keep Frozen; DOUGH INGREDIENTS: Flour, eggs, water, oil (soybean), salt; FILLING INGREDIENTS: Sour Cherry, Sugar; UPC: 707163026150
    Category
    Food
    Distribution
    7 states
  • ModerateFDA (Devices)·Z-3196-2024·2024-10-02

    Philips Ingenia 3.0T CX MRI Machine Carrier Assembly Screws May Loosen

    Philips Ingenia 3.0T CX MRI machines may have loose screws in the RF carrier assembly that could protrude and interfere with the tabletop mechanism, potentially delaying patient scans.

    Product
    Ingenia 3.0T CX - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 782105
    Category
    Medical Device
    Distribution
    Distributed nationwide