The Recall Desk

State

Massachusetts product recalls

73,213 recalls have nationwide distribution and so reach Massachusetts. 8,240 additional recalls listed Massachusetts specifically in their distribution scope.

What the numbers show

Total
8,240
Critical
1,181
Severe
2,025
Most recent
2026-09-30

Of the 8,240 recalls naming Massachusetts we have scored against our rubric, 1,181 (14%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,025 (25%) are Severe.

These figures cover only the 8,240 recalls whose distribution notice names Massachusetts specifically. The 73,213 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

15001–15025 of 81453

  • HighFDA (Drugs)·D-0064-2024·2023-10-25

    Compounded Intranasal Lidocaine-Oxymetazoline Solution Recalled Due to Sterility Assurance

    Pine Pharmaceuticals is recalling 860 syringes of intranasal lidocaine-oxymetazoline solution distributed nationwide due to lack of sterility assurance. Lot 67808 expired 10/23/2023.

    Product
    Lidocaine HCL 2% and Oxymetazoline HCl 0.025% Solution for intranasal administration, 2 mL syringes, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0065-2024·2023-10-25

    Foscarnet Sodium Injectable Recalled Due to Lack of Sterility Assurance

    Pine Pharmaceuticals is recalling Foscarnet Sodium 2.4mg/0.1 mL injectable syringes nationwide due to lack of assurance of sterility. No illnesses or injuries have been reported.

    Product
    Foscarnet Sodium 2.4mg/0.1 mL solution for injection, 0.2 mL single-dose Staclear Luer Slip Syringe, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0053-2024·2023-10-25

    Calcium Gluconate Ophthalmic Irrigation Solution Recall Due to Sterility Concerns

    Pine Pharmaceuticals is recalling Calcium Gluconate Ophthalmic Irrigation Solution 1% (Lot #69802) due to lack of sterility assurance. The 128 bags distributed nationwide may pose infection risk if used.

    Product
    Calcium Gluconate Ophthalmic Irrigation Solution 1%, 500 mL bags, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0057-2024·2023-10-25

    Cefuroxime Injectable Syringes Recalled for Lack of Sterility Assurance

    Pine Pharmaceuticals is recalling 4,972 syringes of Cefuroxime injectable medication due to lack of assurance of sterility. The compounded antibiotic was distributed nationwide.

    Product
    Cefuroxime 4mg /0.4 mL (10 mg/mL), 1mL syringe, Rx only, Compounded by: Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0050-2024·2023-10-25

    Compounded Bevacizumab Injectable Syringes Recalled for Sterility Assurance

    Pine Pharmaceuticals is recalling approximately 2,862 syringes of compounded Bevacizumab 1.25 MG/0.05 ML Solution for Injection due to lack of assurance of sterility. The product was distributed nationwide.

    Product
    Bevacizumab 1.25 MG/0.05 ML Solution for Injection, 1 mL syringes, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0115-2024·2023-10-25

    HydroPICC Catheter Kit Recalled for Missing Safety Warnings

    Access Vascular recalls HydroPICC 5Fr Dual Lumen Maximal Barrier Kits due to incorrect Instructions For Use missing warnings about adult-use only and vessel sizing risks. No adverse events reported.

    Product
    HydroPICC 5Fr Dual Lumen Maximal Barrier Kit, Product Model Number 80002004
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0122-2024·2023-10-25

    Functional MRI Software Bug May Cause DICOM Export Data Mismatch

    A software bug in Functional MR V1.0 can cause file contents and descriptions to not match when exporting multiple regions of interest in DICOM format, potentially leading to misinterpretation of clinical imaging data.

    Product
    Functional MR V1.0
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Drugs)·D-0058-2024·2023-10-25

    FDA Recalls Compounded Moxifloxacin Syringes for Lack of Sterility Assurance

    Pine Pharmaceuticals recalls 2,176 syringes of compounded moxifloxacin nationwide due to inadequate sterility assurance. The product was distributed to healthcare providers and patients.

    Product
    Moxifloxacin in Balanced Salt Solution 400 mcg/0.4 mL (100 mcg/0.1 mL) 1 mL syringes, Rx only, Compounded by: Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0054-2024·2023-10-25

    Calcium Gluconate Inhalation Solution Recalled Due to Sterility Concerns

    Pine Pharmaceuticals is recalling Calcium Gluconate 2.5% inhalation solution due to lack of sterility assurance. Patients should stop using affected syringes and contact their healthcare provider.

    Product
    Calcium Gluconate 2.5% solution for inhalation, 5mL pre-filled syringes, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0114-2024·2023-10-25

    HydroPICC Catheter Kit Recall: Missing Critical Use-Restriction Warnings

    Access Vascular is recalling HydroPICC Dual Lumen Catheter kits with incorrect instruction documents that omit critical warnings about adult-only use and vessel sizing. No adverse events have been reported.

    Product
    HydroPICC 5Fr Dual Lumen, 80cm guidewire - Basic Kit, Product Model Number 80002002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0059-2024·2023-10-25

    Compounded Lidocaine-Phenylephrine Injectable Recalled Due to Sterility Assurance Issues

    Pine Pharmaceuticals is recalling 9,673 vials of compounded lidocaine-phenylephrine injectable due to lack of assurance of sterility. Affected lots were distributed nationwide.

    Product
    Lidocaine-phenylephrine 1%-1.5% 1mL Single Dose Vial, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0051-2024·2023-10-25

    Vancomycin Intraocular Injection Recalled Due to Sterility Assurance Failure

    Pine Pharmaceuticals is recalling 26 vials of Vancomycin 1 MG/0.1 ML intraocular injection (Lot #69985) due to lack of assurance of sterility. The product was distributed nationwide.

    Product
    Vancomycin 1 MG/0.1 ML Solution for Intraocular Injection, 0.8 ML Single Dose Vial, Rx only, Compounded by: Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0055-2024·2023-10-25

    FDA Recalls Compounded Ophthalmic Solution Due to Sterility Concerns

    Pine Pharmaceuticals recalls Tropi-Phen ophthalmic solution due to lack of sterility assurance. The 15 mL droppers were distributed nationwide and customers should not use affected lots.

    Product
    Tropi-Phen (Tropicamide 1% phenylephrine HCl 2.5%) ophthalmic solution, 15 mL multi-use Droppers, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0061-2024·2023-10-25

    Calcium Chloride IV Solution Recalled Due to Sterility Assurance Concerns

    Pine Pharmaceuticals recalls Calcium Chloride IV Solution for Intravenous Injection, 20 mg/mL (lot 70101), due to lack of assurance of sterility. Approximately 130 units were distributed nationwide.

    Product
    Calcium chloride Solution for Intravenous Injection, 20 mg/mL, 500 mL bags, Rx only, Compounded by Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0113-2024·2023-10-25

    Stryker Tornier Reversed Glenoid Baseplate Recalled for Manufacturing Defect

    One lot of Stryker Tornier Perform Reversed Glenoid Baseplate components was manufactured with incorrect 6mm spacers instead of 3mm, preventing proper assembly. The defect affects 30 units distributed across ten US states.

    Product
    stryker Tornier Perform Reversed Augmented Glenoid Lateralized Baseplate, 25mm, Offset +3mm, REF DWJ502
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-0112-2024·2023-10-25

    Monoject tuberculin syringes incompatible with certain IV connectors

    Cardinal Health is recalling Monoject tuberculin syringes because the conical tip is incompatible with certain needleless IV connectors.

    Product
    Monoject(TM) 1 mL Tuberculin Syringe Luer-Lock Tip Soft Pack, Model Number/Product Code: 1180100777
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0056-2024·2023-10-25

    Intraocular Moxifloxacin Injection Recalled Due to Sterility Assurance Issues

    Pine Pharmaceuticals is recalling 2,484 syringes of Moxifloxacin intraocular injection nationwide due to lack of sterility assurance in the compounded product.

    Product
    Moxifloxacin in Balanced Salt Solution, Solution for Intraocular Injection, 600 mcg/0.4mL (150 mcg/0.1mL) Syringe, Rx only, Compounded by: Pine Pharmaceuticals 355 Riverwalk Parkway, Tonawanda, NY 14150.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0296-2024·2023-10-25

    Kraft Singles American Cheese Recalled for Plastic Film Fragment Risk

    Heinz is recalling Kraft Singles American Cheese because thin plastic film fragments may remain on cheese slices after unwrapping. Affected product was distributed nationwide and in Puerto Rico.

    Product
    Kraft Singles American Pasteurized Prepared Cheese product, 24 individually wrapped slices in flexible film per pack, net wt. per pack 16oz, keep refrigerated. Single pack is sold at retail. Case UPC 0 00 2100007180 7; Single Pack UPC 0 2100061526 1: Each case contains 27…
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·23V715000·2023-10-25

    Porsche 911 GT3 air bag control unit may deploy unnecessarily in crash

    Porsche is recalling certain 2021-2024 911 models equipped with optional full bucket seats due to a potential air bag control defect. Unnecessary air bag deployment during a crash could increase injury risk.

    Product
    PORSCHE — PORSCHE 911 GT3, 911 TURBO, 911 TURBO S, 911 GT3 RS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0044-2024·2023-10-25

    Sun Pharmaceutical Bupropion Extended-Release Tablets Recalled for Failed Dissolution

    Sun Pharmaceutical is recalling Bupropion Hydrochloride Extended-Release Tablets (150 mg), lot HAD0360A, due to failed dissolution specifications. The 144 bottles were distributed nationwide and may not dissolve at the intended rate.

    Product
    BUPROPION HYDROCHLORIDE — BUPROPION HYDROCHLORIDE (BUPROPION HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0045-2024·2023-10-25

    Over-the-counter drugs from Family Dollar recalled for improper storage

    Dollar Tree Distribution recalled approximately 4.3 million over-the-counter drug products sold by Family Dollar stores nationwide after discovering they were stored outside of labeled temperature requirements.

    Product
    Certain Over-The-Counter (OTC) drug products sold by Family Dollar retail stores.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0043-2024·2023-10-25

    Ophthalmic Solution Recalled Due to Subpotent Ketorolac Levels

    MYDRIATIC-4 ophthalmic solution is being recalled because ketorolac levels fell below the required 90-110% specification. The product was distributed to physician offices nationwide.

    Product
    MYDRIATIC-4: Tropicamide - Proparacaine - Phenylephrine - Ketorolac Sterile Ophthalmic Solution Drops 1% - 0.5% - 2.5% - 0.5%, 5mL bottle, Imprimis, NJOF, 1705 Route 46 West, Unit 6B, Ledgewood, NJ 07852 (844)-446-6979, NDC:71384-632-05
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0121-2024·2023-10-25

    SenSight Connector Plug Recalled for Use By Date Label Discrepancy

    Medtronic Neuromodulation is recalling 65 units of the SenSight Connector Plug, Model B31061, due to a discrepancy in the Use By Date printed on the device label. The company is requesting return of affected units.

    Product
    SenSight Connector Plug, Model Number B31061.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V713000·2023-10-24

    Mack Recalls 2024 LR Trucks Due to Loose Steering Fasteners

    Mack Trucks is recalling 2024 LR vehicles because loose steering fasteners may cause loss of control. Owners should not drive until repaired.

    Product
    MACK — MACK LR
    Category
    Vehicle
    Distribution
    Distributed nationwide