Most US product recalls have nationwide distribution — the manufacturer ships into every state and the recall sweeps the same way. We include those in this listing because they affect Indiana consumers even though the source notice doesn’t name the state. State-specific recalls are usually for products with regional distribution (a regional dairy, a local store brand) or where the agency was able to narrow the affected shipments to specific destinations.

If you’re checking whether a recall affects your purchase, the recall detail page lists the exact production lot codes, UPCs, and best-by dates. Match those against your package — distribution scope is a starting filter, not the final answer.

10476–10500 of 20303

  • HighFDA (Devices)·Z-0950-2024·2024-02-07

    Philips Ingenia MRI Scanner Body Coil Seal Adhesive May Fail

    Philips is recalling Ingenia 1.5T CX MRI scanners because the Quadrature Body Coil seal adhesive may fail, creating sharp edges that could injure patients. Model numbers 781262 and 781261 are affected.

    Product
    Ingenia 1.5T CX. Model (REF) Numbers 781262, 781261.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0926-2024·2024-02-07

    Tibial Knee Replacement Implants Recalled Due to Material Oxidation

    Howmedica Osteonics is recalling tibial bearing inserts used in knee replacements manufactured from UHMWPE raw material over 5 years old. The material may develop elevated oxidation levels that could impact its structural properties.

    Product
    TIBIAL BEARING INSERT SERIES P-S I ASSY Intended for knee replacement Product Number: 7291-0324
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0948-2024·2024-02-07

    Philips Achieva 3.0T MRI Coil Seal Adhesive May Fail, Risking Patient Injury

    The Quadrature Body Coil seal adhesive in Philips Achieva 3.0T MRI scanners may fail, creating sharp edges that can injure patients. All units with model numbers 781277, 781177, 781278, 781344, and 781345 are affected.

    Product
    Achieva 3.0T. Model. (REF) Numbers 781277, 781177, 781278, 781344, 781345.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0830-2024·2024-02-07

    Surgical kits for childbirth recalled for sterilization and functionality risks

    American Contract Systems is recalling C-section surgical kits that were sterilized without proper assessment. Components may have lost function or drug efficacy, or have excess sterilization residuals.

    Product
    Custom procedural convenience kits and trays, Obstetrical & Gynecological use, labeled as: a) C-SECTION PACK, kit number FDCS01AA; b) C-SECTION PACK, kit number FDCS01AB; c) C-SECTION STERILE PACK, kit number HGCS68J; d) C-SECTION PACK, kit number HICS50H; e) C-SECTION
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0878-2024·2024-02-07

    Knee replacement implant recalled due to material oxidation risk

    Howmedica Osteonics is recalling SCORPIO TS TIB INSERT knee implants (Lot Numbers 482LM8, HH43K7) manufactured with aged UHMWPE material. The raw material is over 5 years old and may develop oxidation that could affect the implant's material properties.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-7514
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0912-2024·2024-02-07

    Knee Replacement Implant Recalled Due to Potential Material Oxidation Risk

    Howmedica Osteonics Corp. is recalling certain knee replacement implants made with UHMWPE material over 5 years old that may have oxidized, potentially affecting implant performance.

    Product
    RGT.LARGE-PCA MOD.REV.- DUR.REV.INSERT Intended for knee replacement Product Number: 6637-0-928
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0920-2024·2024-02-07

    Knee replacement devices recalled due to potential material degradation

    Howmedica Osteonics Corp. recalls knee replacement devices with UHMWPE components manufactured from raw material over 5 years old due to potential oxidation that may affect material properties.

    Product
    DUR PCA MTK REV INS LFT Intended for knee replacement Product Number: 6728-2-611
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0956-2024·2024-02-07

    Philips MRI coil seal adhesive may fail, creating sharp edges and injury risk

    A Philips MRI coil component's adhesive may fail and create sharp edges that could injure patients during scanning. The defect affects 286 units worldwide.

    Product
    SmartPath to dStream for XR and 3.0T. Model (REF) Numbers 781270, 782113, 782129.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0916-2024·2024-02-07

    Knee replacement tibial insert recalled due to material oxidation risk

    Howmedica Osteonics Corp. is recalling DURATION knee replacement tibial inserts manufactured with raw materials over 5 years old that have developed oxidation. Oxidation can degrade the material's structural properties, affecting implant performance.

    Product
    DURATION A-P LIPPED TIB.INSERT-DURAC Intended for knee replacement Product Number: 6642-1-709
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0954-2024·2024-02-07

    MRI Machine Coil Seal Adhesive May Create Sharp Edges

    The Intera Achieva 1.5T Pulsar MRI machine's Quadrature Body Coil seal adhesive may fail, creating sharp edges that could injure patients. All units of this model are affected.

    Product
    Intera Achieva 1.5T Pulsar. Model (REF) Number 781171.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0935-2024·2024-02-07

    Olympus EZDilate Fixed Wire Balloon Device Recalled for Inflation and Deflation Failures

    Olympus recalls 1,008 EZDilate Fixed Wire Balloon devices nationwide due to malfunction during use. Reported failures include inflation and deflation problems, bursting, leaking, and foreign body events in patients.

    Product
    EZDilate Fixed Wire Balloon 11-12-13. Indicated for endoscopic dilation of strictures of the esophagus in adults and adolescents (>12 years). Model: BD-400P-1380
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·23V486000·2024-02-07

    Motorhomes: Overheating HVAC Wiring Could Cause Fires in Entegra, Jayco Models

    Certain 2020-2021 Entegra and Jayco motorhomes are recalled because inadequate HVAC blower motor circuit wiring can overheat, increasing fire risk. The remedy involves relocating and replacing the fuse and wiring harness.

    Product
    ENTEGRA — 2020 ENTEGRA QWEST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0921-2024·2024-02-07

    Knee replacement implant recalled due to potential material degradation

    Howmedica Osteonics recalls DUR PCA MTK REV INS RT knee replacement implants due to potential oxidation of UHMWPE material that could compromise material properties. Patients should contact their healthcare provider.

    Product
    DUR PCA MTK REV INS RT Intended for knee replacement Product Number: 6728-2-709
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0879-2024·2024-02-07

    Knee Replacement Insert Recalled Due to Potential Material Oxidation

    Howmedica Osteonics recalls SCORPIO TS TIB INSERT knee replacement components manufactured with UHMWPE raw material over 5 years old, which may experience elevated oxidation affecting material properties. No injuries or illnesses have been reported.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacment Part Number: 72-4-7516
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0885-2024·2024-02-07

    Knee Replacement Insert Recalled Due to Potential Material Oxidation

    Howmedica Osteonics is recalling Scorpio-Flex knee prosthesis inserts due to potential oxidation in UHMWPE raw material over 5 years old, which could impact material properties.

    Product
    Scorpio-Flex Ttl Kn P-S Tib Brg Insrt Asy- -Intended for knee replacement Part Number: 72-16-0910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0889-2024·2024-02-07

    Total Knee Replacement Component Recalled Due to Oxidation Risk

    Howmedica Osteonics Corp. is recalling SCORPIO Total Knee replacement components from specific manufacturing batches due to potential oxidation in raw materials over 5 years old. Oxidation can impact the material's properties.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #9 -Intended for knee replacement Part Number: 73-0910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0834-2024·2024-02-07

    Endoscopic Surgical Stapler Reload May Fail to Form Complete Staple Line

    An endoscopic surgical stapler reload may fail to properly form staples during use, potentially leaving tissue inadequately sealed. This could lead to bleeding or require additional surgery.

    Product
    ENDOPATH ECHELON 45mm RELOADS WITH GRIPPING SURFACE TECHNOLOGY (GST), ECHELON Endopath Stapler, Endoscopic Linear Cutter Reload (+Gripping Surface technology), 45MM WHITE VASCULAR/THIN, Product No. GST45W
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0819-2024·2024-02-07

    Cardiac central line insertion kits lack documented sterilization validation

    American Contract Systems is recalling 290 cardiac procedural kits nationwide because components were subjected to sterilization without documented assessment of temperature suitability, potentially causing loss of functionality or efficacy.

    Product
    Custom procedural convenience kits and trays, cardiac, labeled as: a) CENTRAL LINE INSERTION PACK, kit number LLCE52; b) Adult Central Line Insertion Supply Kit, kit number UICL44N; c) Pediatric Central Line Insertion, kit number UIPL77K
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0275-2024·2024-02-07

    FDA Recalls Budesonide Extended-Release Tablets for Failed Dissolution

    FDA has recalled approximately 10,672 bottles of Budesonide Extended-Release Tablets 9mg manufactured by Teva Pharmaceuticals due to failed dissolution specifications.

    Product
    BUDESONIDE — BUDESONIDE (BUDESONIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0949-2024·2024-02-07

    Philips Achieva XR MRI Coil Seal Adhesive Failure Risk

    Philips Achieva XR MRI body coil seal adhesive may fail and create sharp edges that could injure patients. Affected units are being recalled.

    Product
    Achieva XR. Model (REF) Numbers 781153, 781253.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0888-2024·2024-02-07

    Knee Replacement Implant Recalled Due to Material Oxidation Risk

    Howmedica Osteonics recalled Scorpio Total Knee prosthetics with UHMWPE components produced from raw material over 5 years old, which may develop elevated oxidation and affect implant properties.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #7 -Intended for knee replacement Part Number: 73-0710
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0828-2024·2024-02-07

    Obstetrical and Gynecological Surgical Kits Recalled for Sterilization Assessment Defects

    American Contract Systems is recalling 1,020 obstetrical and gynecological surgical kits because components were sterilized without documented assessment of their suitability to the process, potentially causing loss of functionality or drug efficacy.

    Product
    Custom procedural convenience kits and trays, Obstetrical & Gynecological use, labeled as: a) LOWER PELVIC PACK, kit number AGLP52L; b) OB/GYN DAVINCI PACK A RG BASIN, kit number HGOB98G; c) DAVINCI GYN PACK, kit number HHDV17; d) KIT, GYNE ROBOTIC, kit number MMGR44D;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0881-2024·2024-02-07

    SCORPIO TS Knee Implant Recall Due to Material Oxidation Risk

    Howmedica is recalling SCORPIO TS knee implants made with raw material over 5 years old due to potential oxidation that could degrade the device's mechanical properties.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-7521
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0274-2024·2024-02-07

    Lupin Pharmaceuticals Recalls Cefixime Suspension Over Failed Specifications

    Lupin Pharmaceuticals is recalling Cefixime for Oral Suspension 100mg/5mL (4,608 bottles) due to failed impurity and degradation specifications. The product was distributed nationwide.

    Product
    CEFIXIME — CEFIXIME (CEFIXIME)
    Category
    Drug
    Distribution
    Distributed nationwide