  • HighNHTSA·26V223000·2026-04-09

    2026 Jeep Cherokee Vehicles Recalled for Brake System Control Module Failure

    Chrysler is recalling certain 2026 Jeep Cherokee vehicles because the brake system control module may fail, causing loss of anti-lock brakes (ABS) and electronic stability control (ESC), which increases crash risk.

    Product
    JEEP — JEEP CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26395·2026-04-09

    Head ski boot shell and sole inserts can deteriorate and break

    Head ski boots with fluorescent yellow components from model years 2016 through 2022 are recalled because those materials can deteriorate and break, posing a risk of injury from a fall.

    Product
    Head Ski Boots
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26403·2026-04-09

    Happiness Light LED lights let children access lithium coin batteries

    Happiness Light LED lights are recalled because their lithium coin batteries can be accessed easily by children, posing an ingestion hazard. About 2,800 units are affected.

    Product
    Happiness Light LED Lights
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1648-2026·2026-04-08

    Trilogy EV300 obstruction alarm may take up to four breaths

    Philips Respironics is recalling the Trilogy EV300 ventilator because in some situations the Obstruction Alarm does not trigger within the timeframe required by the relevant standards.

    Product
    Philips Respironics Trilogy EV300, Software Version 1.05.15.00. Continuous home-use ventilator device.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0478-2026·2026-04-08

    Magnesium sulfate pouch recalled as Class I for containing tranexamic acid

    One lot of Magnesium Sulfate in Water for Injection is being recalled after a foil pouch labeled as magnesium sulfate was found to contain an IV bag of tranexamic acid.

    Product
    MAGNESIUM SULFATE — MAGNESIUM SULFATE (MAGNESIUM SULFATE IN WATER FOR)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1649-2026·2026-04-08

    Trilogy Evo Universal obstruction alarm may take up to four breaths

    Philips Respironics is recalling the Trilogy Evo Universal ventilator because in some situations the Obstruction Alarm does not trigger within the timeframe required by the relevant standards.

    Product
    Philips Respironics Trilogy Evo Universal, Software Version 1.05.15.00. Continuous home-use ventilator device.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1646-2026·2026-04-08

    Trilogy Evo obstruction alarm may take up to four breaths

    Philips Respironics is recalling the Trilogy Evo ventilator because in some situations the Obstruction Alarm does not trigger within the timeframe required by the relevant standards.

    Product
    Philips Respironics Trilogy Evo, Software Version 1.05.15.00. Continuous home-use ventilator device.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1647-2026·2026-04-08

    Trilogy Evo O2 obstruction alarm may take up to four breaths

    Philips Respironics is recalling the Trilogy Evo O2 ventilator because in some situations the Obstruction Alarm does not trigger within the timeframe required by the relevant standards.

    Product
    Philips Respironics Trilogy Evo O2, Software Version 1.05.15.00. Continuous home-use ventilator device.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·H-0661-2026·2026-04-08

    Imu-Tek Colostrum-5 Powder Recalled Due to Under-Processing Risk

    Imu-Tek Animal Health has recalled Imu-Tek Colostrum-5 Powder because the product may be under-processed. The recalled lot was distributed across 29 states.

    Product
    Imu-Tek Colostrum-5 Powder; 30% IgG,1,000 mg 2x/day, orally with 8 ounces of water, support a healthy immune system, 3 year shelf life, plastic bottle, inner liner seal and shrink band exterior seal, 24 ounces (680 grams) powder, 7 38654 00052 6, ImuTek Laboratories, Fort Collins
    Category
    Food
    Distribution
    30 states
  • HighFDA (Devices)·Z-1753-2026·2026-04-08

    Burlington Medical thyroid shields may lose radiation attenuation over time

    Burlington Medical is recalling thyroid shields over the potential for attenuation degradation over time, which decreases the product's usable lifespan. 41,962 units are affected.

    Product
    Burlington Medical, Thyroid Shield.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1767-2026·2026-04-08

    GE SIGNA Premier MRI magnets may have ferrous fittings fitted

    SIGNA Premier MRI systems are being recalled because they may have been built or serviced with ferrous steel fittings instead of non-ferrous brass on the magnet rear.

    Product
    SIGNA Premier systems
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1693-2026·2026-04-08

    Sterile radiology procedure kits may have a breached sterile pouch

    One lot of Sterile Radiology Procedure Kits, model DYNDH1491B, is being recalled because of a potential breach in the sterile pouch packaging that may compromise sterility.

    Product
    Sterile Radiology Procedure Kits, Model Number DYNDH1491B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1692-2026·2026-04-08

    Vue Motion V12 may display cine image frames out of sequence

    Philips is recalling Vue Motion V12 because mis-ordered frames during dynamic cine runs may cause image frames to display out of sequence.

    Product
    Vue Motion V12. Product Number: 1017979.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1707-2026·2026-04-08

    Medline thoracic robot kits contain recalled Olympus biopsy valves

    Medline is recalling Thoracic Robots kits, model DYNJ908777B, because they contain recalled Olympus biopsy valves where rubber fragments may detach from the valve slit.

    Product
    THORACIC ROBOTS, DYNJ908777B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1751-2026·2026-04-08

    MiniMed 530G insulin pump delivery varies with pump height changes

    Medtronic is recalling MiniMed 530G insulin pumps because raising or lowering the pump relative to the infusion site can cause unintended over- or under-delivery of insulin.

    Product
    MiniMed 530G Insulin Pump (MMT-551, MMT-751)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1654-2026·2026-04-08

    Paradise renal denervation catheter unit distributed despite scrapping designation

    One Paradise Ultrasound Renal Denervation catheter was distributed although it was a nonconforming product that should have been scrapped and not used in humans.

    Product
    Brand Name: Paradise¿ Ultrasound Renal Denervation System Product Name: Paradise ¿ Catheter Model/Catalog Number: PRDS-068-02 Product Description: Common name: Ablation catheter renal denervation
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1740-2026·2026-04-08

    MiniMed 630G insulin pump delivery varies with pump height changes

    Medtronic is recalling MiniMed 630G insulin pumps because raising or lowering the pump relative to the infusion site can cause unintended over- or under-delivery of insulin.

    Product
    MiniMed 630G Insulin Pump (MMT-1714, MMT-1715, MMT-1754, MMT-1755)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1755-2026·2026-04-08

    Burlington Medical kilts may lose radiation attenuation over time

    Burlington Medical is recalling kilts made with Xenolite 800 attenuation material because of the potential for attenuation degradation over time.

    Product
    Burlington Medical, Kilt
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0637-2026·2026-04-08

    Divided Sunset Multi Collagen Peptides Missing Allergen Labeling

    TG FOODS INC is recalling Divided Sunset Multi Collagen Peptides (8 oz) because the product contains eggshell membrane collagen and wild-caught marine collagen but fails to declare EGG and the specific fish species on the label.

    Product
    Divided Sunset Multi Collagen Peptides, 8 Ounce, Stand-up Pouch, UPC Code: 8 50005 60689 5
    Category
    Food
    Distribution
    28 states
  • HighFDA (Food)·H-0660-2026·2026-04-08

    Imu-Tek Colostrum-5 Capsules Recalled for Potential Under-Processing

    Imu-Tek Animal Health is recalling Imu-Tek Colostrum-5 120 Capsules (Lot #013, Expiration 092826) because the product is potentially under-processed. The product was distributed across 29 states.

    Product
    Imu-Tek Colostrum-5 120 Capsules; 30% IgG, 2 capsules 2x/day, orally with 8 ounces of water, support a healthy immune system, 3 year shelf life, plastic bottle, inner liner seal and shrink band seal, 500 mg capsule, 7 38654 00026 7, Imu-Tek, Inc. Ft. Collins, CO 80524.
    Category
    Food
    Distribution
    30 states
  • HighFDA (Devices)·Z-1757-2026·2026-04-08

    Burlington Medical wrap aprons may lose radiation attenuation over time

    Burlington Medical is recalling wrap aprons made with Xenolite 800 attenuation material because of the potential for attenuation degradation over time.

    Product
    Burlington Medical, Wrap Aprons.
    Category
    Medical Device
    Distribution
    Distributed nationwide