Most US product recalls have nationwide distribution — the manufacturer ships into every state and the recall sweeps the same way. We include those in this listing because they affect Hawaii consumers even though the source notice doesn’t name the state. State-specific recalls are usually for products with regional distribution (a regional dairy, a local store brand) or where the agency was able to narrow the affected shipments to specific destinations.

If you’re checking whether a recall affects your purchase, the recall detail page lists the exact production lot codes, UPCs, and best-by dates. Match those against your package — distribution scope is a starting filter, not the final answer.

10326–10350 of 20307

  • HighFDA (Devices)·Z-0993-2024·2024-02-14

    FilmArray Pneumonia Panel Plus Test Kits Recalled for False Positive Results

    BioFire Diagnostics is recalling FilmArray Pneumonia Panel Plus diagnostic test kits due to a potential for false positive results. These inaccurate results could lead to incorrect pneumonia diagnoses.

    Product
    FilmArray Pneumonia Panel Plus (Pneumoplus), REF: RFIT-ASY-0143, CED 2797, IVD, Rx Only (30 test kit)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0977-2024·2024-02-14

    RotaFlow Centrifugal Pump Seal Defect Poses Infection Risk

    Maquet Medical Systems is recalling 1,090 RotaFlow centrifugal pumps used in heart surgery due to seal defects that could compromise sterile barriers and expose patients to infection.

    Product
    BEQ-RF-32-USA RotaFlow Centrifugal Pump with BIOLINE Coating, Product Code 701047554. For use with an extracorporeal cardiovascular or cardiopulmonary bypass circuit.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0997-2024·2024-02-14

    Globus Medical Cranial Drill recalled for sterility breach risk

    Globus Medical is recalling Cranial Drill 6.00mm units due to potential packaging breaches that may render the sterile product non-sterile, and discoloration near the drill tip.

    Product
    Globus Medical Cranial Drill, 6.00mm - instruments for access, preparation, and placement of cranial devices with the ExcelsiusGPS. Ref: 6143.1870S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1008-2024·2024-02-14

    Brasseler dental burs recalled due to defective latching mechanism

    Brasseler USA recalls 440 dental burs due to right angle latch specification failure that prevents proper latching in dental handpieces.

    Product
    Brasseler 8S RA SHP RD (Super-Sharp Round) H1S.21.023, REF 001156T0), carbide dental bur, 10 burs/package, Rx.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1032-2024·2024-02-14

    BD BBL Sensi Disc Levofloxacin Testing Discs Recalled for Accuracy Failures

    Becton Dickinson is recalling 2,363,168 units of BD BBL Sensi Disc Levofloxacin testing discs (Catalog No. 231705, 231706) due to potential accuracy and quality control failures in antibiotic susceptibility testing that could lead to delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Levofloxacin- 5 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231705 and 231706¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0289-2024·2024-02-14

    FDA Recalls Omeza Skin Protectant Gel Due to Manufacturing Deviations

    OMEZA LLC is recalling Omeza Skin Protectant Gel due to Current Good Manufacturing Practice (CGMP) deviations. The recall affects 1,210 vials distributed nationwide.

    Product
    Omeza Skin Protectant, Skin Protectant Gel 10*2mL Vials
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1024-2024·2024-02-14

    BD BBL Sensi Disc Ceftriaxone Test Discs Recalled for Susceptibility Testing Accuracy Issues

    BD BBL Sensi Disc Ceftriaxone susceptibility test discs may have accuracy and quality control failures. These defects could lead to delayed diagnosis or incorrect antibiotic selection for H. influenzae infections.

    Product
    BD BBL Sensi Disc Ceftriaxone- 30 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231634 and 231635¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0982-2024·2024-02-14

    Laboratory Analyzer Software Bug Could Produce Erroneous Clinical Test Results

    Beckman Coulter DxI 9000 immunoassay analyzers may produce erroneous lab results due to software bugs affecting unit conversion and result calculation. Affected devices use software version 1.16 or earlier; 128 devices worldwide are impacted.

    Product
    DxI 9000 Access Immunoassay Analyzer running software version 1.16 or prior,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1033-2024·2024-02-14

    BD BBL Sensi Disc Meropenem testing discs recalled for accuracy failures

    Becton Dickinson is recalling BD BBL Sensi Disc Meropenem antibiotic susceptibility testing discs due to accuracy and quality control failures that may cause delayed or incorrect diagnostic results.

    Product
    BD BBL Sensi Disc Meropenem- 10 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231703 and 231704¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1011-2024·2024-02-14

    Lab testing discs recalled for potential antibiotic susceptibility testing failures

    Becton Dickinson recalled 2.3 million lab testing discs used for antibiotic susceptibility testing due to potential quality control failures. These failures could lead to delayed diagnosis or inappropriate antibiotic selection.

    Product
    Sensi Disc Amoxicillin with Clavulanic Acid 20/10 ¿g, Catalog No. 231628 and 231629.¿ These discs are used for semi-quantitative in vitro susceptibility testing
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0976-2024·2024-02-14

    Orthodontic Latex Elastics Mislabeled as Non-Latex by Manufacturer

    FLEXSelect 5/16" Amber Latex Elastics were labeled as non-latex, creating allergy risk for latex-sensitive patients. Patients with latex allergies should immediately stop using the product.

    Product
    FLEXSelect 5/16" Amber Latex Elastics-Intended use is orthodontics, braces, tooth gap, Ref: AMD56
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1034-2024·2024-02-14

    Antibiotic Susceptibility Test Discs Recalled for Accuracy and QC Failures

    Becton Dickinson is recalling BD BBL Sensi Disc Minocycline test discs due to potential accuracy and quality control failures that may cause delayed test results, missed diagnoses, or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Minocycline - 30 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231250 and 231251¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1039-2024·2024-02-14

    BD BBL Sensi Disc Antibiotic Test Discs Recalled for Accuracy Failures

    Becton Dickinson is recalling BD BBL Sensi Disc antibiotic susceptibility test discs due to potential accuracy and quality control failures that may lead to incorrect antibiotic selection and delayed diagnosis.

    Product
    BD BBL Sensi Disc Sulfamethoxazole with Trimethoprim 23.75/1.25 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231536 and 231539¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0995-2024·2024-02-14

    Globus Medical Cranial Drills recalled for sterility loss and discoloration

    Globus Medical is recalling Cranial Drills (2.40mm) due to packaging breaches that may compromise sterility and discoloration near the drill tip. Distributed worldwide.

    Product
    Globus Medical Cranial Drill with Stop, 2.40mm - Instruments for access, preparation, and placement of cranial devices with the ExcelsiusGPS. Ref : 6143.1834S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1040-2024·2024-02-14

    BD Sensi Disc Tetracycline Recalls Due to Accuracy and QC Failures

    Becton Dickinson & Co. is recalling BD BBL Sensi Disc Tetracycline 30µg laboratory test kits due to potential accuracy and quality control failures in antibiotic susceptibility testing that could lead to delayed diagnosis or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Tetracycline 30 ug,used for semi-quantitative in vitro susceptibility testing. Catalog Number 230998 and 231344¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0984-2024·2024-02-14

    Dual Articulating Headrest May Fail to Lock During Surgery

    Steris Corporation is recalling Dual Articulating Headrests that may fail to lock in position during patient procedures, potentially causing patient injury. Affected units were manufactured between August and October 2023.

    Product
    Dual Articulating Headrest, Velcro P/N P141210813, REF BF753
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1021-2024·2024-02-14

    BD Sensi Disc Cefpodoxime Antibiotic Testing Discs Recalled for Accuracy Failures

    Becton Dickinson is recalling BD BBL Sensi Disc Cefpodoxime testing discs due to potential accuracy failures in antibiotic susceptibility testing. The defect may cause inaccurate results, delayed diagnosis, or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Cefpodoxime - 10 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231673 and 231674¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1023-2024·2024-02-14

    BD BBL Antibiotic Susceptibility Test Discs Recalled for Accuracy Failures

    BD BBL Ceftazidime Sensi Discs used for antibiotic susceptibility testing may have accuracy failures affecting H. influenzae testing. This could lead to delayed diagnoses or inappropriate antibiotic selection.

    Product
    BD BBL Sensi Disc Ceftazidime- 30 ug, used for semi-quantitative in vitro susceptibility testing. Catalog Number 231632¿and 231633¿
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0318-2024·2024-02-14

    FDA Recalls Lansoprazole Delayed-Release Capsules Due to Manufacturing Defects

    The FDA is recalling Lansoprazole Delayed-Release Capsules USP 15 mg due to manufacturing defects including inadequate sealing, capsule damage, and missing product codes. Affected lot 411987 was distributed nationwide.

    Product
    Lansoprazole Delayed-Release Capsules USP, 15 mg, 14-count bottle, Manufactured by: Natco Pharma Limited Kothur- 509 228, India, Distributed by: Rising Pharma Holdings, Inc. East Brunswick, NJ. 08816. NDC 16571-742-41
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0978-2024·2024-02-14

    RotaFlow Centrifugal Pump sterile barrier defect FDA Class II recall

    RotaFlow Centrifugal Pumps have potential seal defects that could compromise sterile barriers, risking infection in cardiac bypass patients. FDA recommends device identification and contact with manufacturer for remediation.

    Product
    BO-RF-32-USA RotaFlow Centrifugal Pump with SOFTLINE Coating, Product Code 701047553. For use with an extracorporeal cardiovascular or cardiopulmonary bypass circuit.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1009-2024·2024-02-14

    Water Filter MAJ-2318 May Be Incorrectly Assembled, Risking Infection

    Olympus MAJ-2318 water filters may be assembled incorrectly, allowing unfiltered tap water to contaminate reprocessed endoscopes and expose patients to infection risk.

    Product
    Water Filter MAJ-2318. This MAJ-2318 water filter has been designed to be used with Olympus endoscope reprocessor for prevent contamination of the rinse water. The MAJ-2318 water filter is compatible with OER-ELITE and OER-MINI.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0994-2024·2024-02-14

    FilmArray Pneumonia Diagnostic Panel: Potential False Positive Results

    BioFire Diagnostics is recalling the FilmArray Pneumonia Panel diagnostic test kit due to the potential for false positive results. The recall affects 274,290 units distributed worldwide.

    Product
    FilmArray Pneumonia Panel (Pneumo), REF: FIT-ASY-0144, CED 2797, IVD, Rx Only (30 test kit)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1007-2024·2024-02-14

    Globus Medical Cannula May Not Be Properly Sterilized

    Some ExcelsiusGPS Cannulas have an internal gap that prevents proper sterilization, increasing infection risk. Globus Medical is recalling 570 units distributed worldwide.

    Product
    ExcelsiusGPS Cannula A, 9mm x 250mm, Cannula used with ball tip probes, Model No. 6143.2844
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1005-2024·2024-02-14

    Medical Device Recall: Guardian 4 Glucose Sensor Manufacturing Defect

    Medtronic is recalling Guardian 4 Glucose Sensors due to manufacturing defects in the glucose oxidase layer. Defects may cause sensors to malfunction or provide inaccurate readings, potentially affecting insulin dosing.

    Product
    Guardian 4 Glucose Sensor, REF: MMT-7040A, MMT-7040C1, MMT-7040C2, MMT-7040C3, MMT-7040D1, MMT-7040D2, MMT-7040MA, MMT-7040QC1, MMT-7040QC2, MMT-7040QC3
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0862-2024·2024-02-14

    Senographe Pristina X-ray system missing audible exposure termination signal

    GE Medical Systems is recalling 180 Senographe Pristina mammography X-ray systems because the audible signal indicating the end of X-ray exposure intermittently fails to sound, violating FDA safety requirements.

    Product
    Senographe Pristina
    Category
    Medical Device
    Distribution
    Distributed nationwide