  • HighFDA (Devices)·Z-2425-2025·2025-09-03

    Limb salvage stem extensions recalled after unidentified substance found on devices

    ELEOS Segmental Limb Salvage System straight splined slotted stem extensions are recalled because an unidentified substance of unknown impact was found on devices during a retrospective evaluation. 554 units are affected.

    Product
    ELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS STEM EXTENSION, STRAIGHT, SPLINED, SLOTTED. Canal filling stem implants.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2440-2025·2025-09-03

    Custom loupes with Dragonfly frames recalled over nickel nose pad allergy risk

    Orascoptic custom loupes with Dragonfly frames are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 15,245 units are affected.

    Product
    Orascoptic Superior Visualization Custom loupes with Dragonfly frames
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0600-2025·2025-09-03

    Medline alcohol prep pads recalled for alcohol below labeled concentration

    Medline Alcohol Prep Pads, 70% isopropyl alcohol, are recalled nationwide because isopropyl alcohol levels fall below the labeled concentration. The recall covers 6,669,874 swabs.

    Product
    MEDLINE ALCOHOL PREP — MEDLINE ALCOHOL PREP (ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2444-2025·2025-09-03

    Loupe nose pad kits recalled because nickel content may cause allergic reaction

    Orascoptic Dragonfly Nose Pad Accessory Kits are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 743 kits are affected.

    Product
    Orascoptic Superior Visualization Dragonfly Nose Pad Accessory Kit ( nose pad and screw) 1 pk and 20 pk.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0601-2025·2025-09-03

    CURAD alcohol prep pads recalled for isopropyl alcohol below labeled strength

    CURAD Sterile Alcohol Prep Pads, medium 2-ply, are recalled nationwide because isopropyl alcohol levels fall below the labeled concentration. The recall covers 1,639,996 pads.

    Product
    CURAD ALCOHOL PREP PADS — CURAD ALCOHOL PREP PADS (ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0546-2025·2025-09-03

    Ice cream cartons recalled over undeclared almond, walnut and pecan

    Chocolate Chip Cookie Dough ice cream in half gallon cartons carrying a Moo-llennium Crunch lid is recalled for undeclared almond, walnut and pecan. 16,532 half gallons are affected.

    Product
    Chocolate Chip Cookie Dough ice cream cartons with a Moo-llennium Crunch lid. Packaging contains Moo-llennium crunch. Packaged in half gallon cartons (1.89 L)
    Category
    Food
    Distribution
    17 states
  • HighFDA (Devices)·Z-2479-2025·2025-09-03

    Surgical kits recalled because Foley tray inserts carry incorrect product information

    Medline kits containing BD SureStep Foley Tray Systems are recalled because the trays include incorrect product information insert sheets. Four units were distributed, all from the LAVH MINOR SKU.

    Product
    Medline Kits containing BD SureStep Foley Tray Systems: SKU/Description: CDS984076J GYN ROBOTIC DYNJG001004A LAVH MINOR DYNJG901001B CRANIOTOMY DYNJ908819B KIT CRANIOTOMY (only units from SKU DYNJG001004A LAVH MINOR were distributed)
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-2423-2025·2025-09-03

    Limb salvage canal filling stems recalled after unidentified substance found on devices

    ELEOS Bowed Canal Filling Stems are recalled because an unidentified substance of unknown impact was found on devices during a retrospective evaluation. 30 units are affected.

    Product
    ELEOS SEGMENTAL LIMB SALVAGE SYSTEM, ELEOS BOWED CANAL FILLING STEMS. Canal filling stem implants.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2462-2025·2025-09-03

    Foley catheters recalled because obstructed lumen may prevent bladder drainage

    Bardex Lubri-Sil I.C. Foley catheters and related tray systems are recalled because the catheter may have an obstructed lumen, which may prevent the bladder from draining. 175,158 units are affected.

    Product
    Bardex Lubri-Sil I.C. 400-series Temperature Sensing Silver/Hydrogel Coated All-Silicone Foley Catheter 5cc Balloon, REF: 119314; SureStep Foley Tray System Lubri-Sil I.C. Complete Care, REF: A319514A; Bard Silver Lubri-Sil Foley Tray Temperature Sensing with Bard Hydrogel and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0605-2025·2025-09-03

    Alcohol prep pads recalled for isopropyl alcohol below labeled concentration

    Rite Aid Pharmacy first aid alcohol prep pads are recalled nationwide because isopropyl alcohol levels fall below the labeled concentration. The recall covers 984,000 pads.

    Product
    ALCOHOL — ALCOHOL (ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2443-2025·2025-09-03

    Phantom Essential loupe kits recalled because nickel nose pads may cause allergy

    Orascoptic Phantom Essential Kits are recalled because loupe nose pads containing nickel may cause an allergic reaction, following complaints. 74 kits are affected.

    Product
    Orascoptic Superior Visualization Phantom Essential kit ( Nose pad, a screw, lens cleaning wipe, side shields, head strap, and a screwdriver)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V570000·2025-09-03

    Ducati Motorcycles Recalled for Defective Rear Wheel Axle

    Ducati is recalling certain 2018-2025 motorcycles because the rear wheel axle may lose structural integrity and break during riding, risking loss of control. Dealers will replace the axle free of charge.

    Product
    DUCATI — DUCATI STREETFIGHTER, STREETFIGHTER V2, PANIGALE V4 S, STREETFIGHTER V4
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E054000·2025-09-03

    Magna Recalls Rearview Cameras on Ford and Chrysler Vehicles

    Magna International is recalling rearview cameras installed on certain Ford and Chrysler vehicles because they may display a blank or inverted image, increasing crash risk.

    Product
    BACK OVER PREVENTION: SENSING SYSTEM: CAMERA recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2474-2025·2025-09-03

    Anti-Xa 4 test kits recalled over potential fibrinogen reagent contamination

    STA-Liquid Anti-Xa 4 kits are recalled because of the potential for contamination by Stago Fibrinogen reagents in unfractionated and low molecular weight heparin applications. 116,600 units are affected.

    Product
    STA-Liquid Anti-Xa 4. Model/Catalog Number: 00311US. The STA - Liquid Anti-Xa kits are intended for use with STA-R, STA Compact and STA Satellite analyzers, for the quantitative determination of the plasma levels of unfractionated (UFH) and low molecular weight (LMWH) heparins
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2475-2025·2025-09-03

    Anti-Xa test kits recalled over potential contamination by fibrinogen reagents

    STA-Liquid Anti-Xa 8 kits are recalled because of the potential for contamination by Stago Fibrinogen reagents in unfractionated and low molecular weight heparin applications. 126,200 units are affected.

    Product
    STA-Liquid Anti-Xa 8. Model/Catalog Number: 00322US. The STA - Liquid Anti-Xa kits are intended for use with STA-R, STA Compact and STA Satellite analyzers, for the quantitative determination of the plasma levels of unfractionated (UFH) and low molecular weight (LMWH) heparin
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2453-2025·2025-09-03

    Drug transfer devices recalled for shipping without US instructions for use

    BD PhaSeal closed system drug transfer devices are recalled because they were shipped to the US market without a US version of the instructions for use. 3,884,670 units are affected.

    Product
    BD PhaSeal Injector Luer (N30C), REF: 515001 BD PhaSeal Injector Luer Lock (N35), REF: 515003 BD PhaSeal Injector Luer Lock (N35C), REF: 515004 BD PhaSeal Injector Lu63er Lock (N35C Multi), REF: 515005 BD PhaSeal Protector (P14), REF: 515100 BD PhaSeal Protector (P21), REF:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2477-2025·2025-09-03

    Medication dispensing stations recalled because antivirus software was not consistently installed

    BD Pyxis MedStation and Anesthesia Station devices are recalled because antivirus software was not consistently installed during implementation. 8,353 devices are affected, 6,738 of them in the US.

    Product
    BD Pyxis Product Name / UDI-DI code / Catalog No. BD Pyxis" MedStation" 4000 Main / 10885403512629 / 303 BD Pyxis" MedStation" ES Tower / 10885403512674 / 352 BD Pyxis" Anesthesia Station ES / 10885403477836 / 327 BD Pyxis" MedStation" ES (Main) / 10885403512667 / 323
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2422-2025·2025-09-03

    Atlantis IO FLO-S kits recalled over thread defect limiting implant engagement

    Atlantis IO FLO-S Kits, catalog A04S / 68020034, are recalled because a thread defect stops the device fully engaging an implant or analog, engaging about two rotations instead of five. 780 units are affected.

    Product
    Brand Name: Atlantis IO FLO Product Name: Atlantis IO FLO-S Kit Model/Catalog Number: A04S / 6802034 Product Description: The Atlantis intraoral feature locating object for suprastructures (IO FLO-S) is intended to support the prosthetic procedure with the aim of restoring che
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2473-2025·2025-09-03

    Coagulation analyzers recalled over potential reagent contamination in anti-Xa testing

    STA Satellite analyzers are recalled because of the potential for contamination of STA-LIQUID ANTI-Xa by Stago Fibrinogen reagents in unfractionated and low molecular weight heparin applications. 3,650 units are affected.

    Product
    STA Satellite. Product Code: All references. All software versions. The STA Satellite is a fully automated benchtop analyzer capable of simultaneously performing clotting, chromogenic, and immunologic assays.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2416-2025·2025-09-03

    NovoTHOR light therapy devices recalled over welded nut that may shear

    NovoTHOR devices, model S2188, are recalled because a failed welded nut may shear off, detaching a gas strut from the canopy and making the canopy difficult to lift. 80 units are affected.

    Product
    Brand Name: THOR Product Name: NovoTHOR Model/Catalog Number: S2188 Software Version: N/A Product Description: The NovoTHOR and NovoTHOR XL are intended to emit energy in the visible and IR spectrum to provide topical heating for the purpose of elevating tissue temperature fo
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2417-2025·2025-09-03

    NovoTHOR XL devices recalled over failed welded nut detaching gas strut

    NovoTHOR XL devices, model S2190, are recalled because a failed welded nut may shear off, detaching a gas strut from the canopy and making the canopy difficult to lift. 55 units are affected.

    Product
    Brand Name: THOR Product Name: NovoTHOR XL Model/Catalog Number: S2190 Software Version: N/A Product Description: The NovoTHOR and NovoTHOR XL are intended to emit energy in the visible and IR spectrum to provide topical heating for the purpose of elevating tissue temperature
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2476-2025·2025-09-03

    Fibrinogen test kits recalled over potential cross-contamination in heparin assays

    STA-Fibrinogen 5 kits are recalled because of the potential for contamination of STA-LIQUID ANTI-Xa by Stago Fibrinogen reagents in heparin applications. 829,800 units are affected, 245,200 of them in the US.

    Product
    STA - Fibrinogen 5. Model/Catalog Number: 00674. The STA - Fibrinogen 5 kit is intended for use with the analyzers of the STA-R, STA Compact and STA Satellite families for the quantitative determination of fibrinogen levels in human citrated plasma by the clotting method of
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2421-2025·2025-09-03

    Dental implant locating kits recalled over thread defect limiting full engagement

    Atlantis IO FLO-S Kits are recalled because a thread defect stops the device fully engaging an implant or analog, engaging about two rotations instead of five. 102 units are affected.

    Product
    Brand Name: Atlantis IO FLO-S Product Name: Atlantis IO FLO-S Kit Model/Catalog Number: A04B / 68020033 Software Version: n/a Product Description: The Atlantis intraoral feature locating object for suprastructures (IO FLO-S) is intended to support the prosthetic procedure wit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2418-2025·2025-09-03

    NovoTHOR Gen 3.0 unit recalled because gas strut may detach from canopy

    A single NovoTHOR Gen 3.0 Reg PRX unit, model S2189, is recalled because a failed welded nut may shear off, detaching a gas strut from the canopy and making the canopy difficult to lift.

    Product
    Brand Name: THOR Product Name: NovoTHOR Gen 3.0 Reg PRX Model/Catalog Number: S2189 Software Version: N/A Product Description: The NovoTHOR and NovoTHOR XL are intended to emit energy in the visible and IR spectrum to provide topical heating for the purpose of elevating tissu
    Category
    Medical Device
    Distribution
    Distributed nationwide