The Recall Desk

State

Arkansas product recalls

73,218 recalls have nationwide distribution and so reach Arkansas. 5,542 additional recalls listed Arkansas specifically in their distribution scope.

What the numbers show

Total
5,542
Critical
1,029
Severe
1,222
Most recent
2026-09-23

Of the 5,542 recalls naming Arkansas we have scored against our rubric, 1,029 (19%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,222 (22%) are Severe.

These figures cover only the 5,542 recalls whose distribution notice names Arkansas specifically. The 73,218 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

15476–15500 of 78760

  • HighFDA (Drugs)·D-0949-2023·2023-08-09

    Succinylcholine Injectable Syringes Recalled for Unvalidated Decontamination Cycles

    Central Admixture Pharmacy Services recalls 26,208 succinylcholine injection syringes nationwide due to lack of validated sterilization procedures. The manufacturer lacks adequate validation data for decontamination cycles.

    Product
    succinylcholine 200 mg/10 mL (20 mg/mL), Syringe, Rx only, this drug was repackaged by CAPS Inc, 2200 South 43rd Avenue Pheonix, AZ, NDC 72196-6011-2.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2278-2023·2023-08-09

    Medical X-ray Systems Image Intensifier Detachment Injury Risk

    GE OEC Elite Systems with 9-inch Image Intensifier devices may detach during movement if subjected to impact force, potentially causing injury to personnel and bystanders.

    Product
    OEC Elite Systems with 9-inch Image Intensifier
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0978-2023·2023-08-09

    Heparin IV Bags Recalled for Lack of Sterility Assurance

    Central Admixture Pharmacy Services is recalling 11,824 bags of heparin IV solution nationwide. The recall is due to lack of assurance of sterility and missing validation data for decontamination cycles.

    Product
    heparin 4000 units/1000mL added to 0.9% sodium chloride, 4 units/mL, IV Bag, Rx only, Cental Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-7022-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2318-2023·2023-08-09

    Medical Procedural Kits Recalled Due to Ultrasound Gel Sterility Risk

    Medline Industries is recalling 1,182 sterile and non-sterile procedural kits because the ultrasound gel component may not meet sterility specifications. The affected kits were distributed worldwide between April 2020 and April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. CATH LAB BASIN PACK, Model Number: DYNJ69864A; b. DELNOR VASCULAR BASIN PACK, Model Number: DYNJ82257; c. FLAP PACK, Model Number: DYNJ60224C;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2314-2023·2023-08-09

    Medline procedural kits with potentially non-sterile ultrasound gel recalled

    Medline Industries is recalling 80 custom procedural kits containing ultrasound gel that may not meet sterility specifications. Kits were distributed worldwide from April 2020 to April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. PACK ENDO AAA HYBRID CHRG, Model Number: DYNJ60126B;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1055-2023·2023-08-09

    Hydromorphone Injection Syringes Recalled for Sterility Validation Deficiency

    Central Admixture Pharmacy Services is recalling 2,389 hydromorphone injection syringes distributed nationwide due to lack of validation data for sterilization procedures, which prevents assurance of product sterility.

    Product
    HYDROmorphone in 0.9% sodium chloride, 10 mg/50 mL, (0.2 mg/mL), 50 mL Syringe, Rx only, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC 71286-2010-2
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2324-2023·2023-08-09

    Medline Medical Procedural Kits Recalled for Potential Ultrasound Gel Sterility Failure

    Medline Industries recalls 19,907 procedural kits because the sterile ultrasound gel component may not meet sterility specifications.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. CENTRAL LINE INSERT KIT W/O CA, Model Number: CVI3755; b. CENTRAL LINE KIT, Model Number: DYNDC2582, DYNDC2582A; c. CENTRAL LINE PACK-COMPANION, Model…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1013-2023·2023-08-09

    Oxytocin IV bags recalled nationwide for insufficient sterility assurance

    Central Admixture Pharmacy Services recalled 2,692 bags of oxytocin IV solution nationwide because the company lacks data needed to prove the sterilization process is effective.

    Product
    oxyTOCIN, 40 units added to 0.9% sodium chloride 1000 mL, IV Bag, Rx Only, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-8069-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2276-2023·2023-08-09

    OEC 9800 Fluoroscopy Systems Image Intensifier May Detach and Fall

    The image intensifier on GE OEC 9800 fluoroscopy systems can detach and fall if the system experiences a large impact force during movement. This could result in injuries including fractures, bruising, and contusion.

    Product
    OEC 9800 Systems with 9-inch Image Intensifier
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1048-2023·2023-08-09

    Vecuronium Injection Recalled Due to Lack of Sterility Validation

    Vecuronium injection syringes were recalled nationwide due to lack of validation data for sanitization cycles, which raises sterility assurance concerns.

    Product
    vecuronium, 10 mg/10mL, (1 mg/mL), 10 mL syringe, Rx only, PARALYZING AGENT, CAPS, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC: 71286-6012-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1076-2023·2023-08-09

    Rocuronium Syringes Recalled for Lack of Sterility Validation

    Central Admixture Pharmacy Services is recalling rocuronium syringes due to lack of validation data for sanitization cycles, which cannot assure sterility. The recall affects 10,065 syringes distributed nationwide.

    Product
    rocuronium, 50 mg /5 mL, (10 mg/mL), 5 mL Syringe, Rx only, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC: 71286-6010-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1041-2023·2023-08-09

    FDA Recalls Cardioplegia Solution for Lacking Sterility Validation Data

    Central Admixture Pharmacy Services is recalling a cardioplegia solution used during heart surgery due to insufficient validation data for sterilization cycles. The 104-bag recall covers products distributed nationwide.

    Product
    CARDIOPLEGIA SOLUTION, 24 mEq K, Maintenance 8:1 non-enriched, Low Potassium, IV Bag, Total Volume = 300 mL, RX only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC 72196-0215-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2260-2023·2023-08-09

    Philips Incisive CT Scanner Mounting Box Poses Injury Risk

    A metal mounting box in the Incisive CT Power scanner may detach and potentially injure operators or cause system failure. Philips is recalling 53 affected units distributed worldwide.

    Product
    Incisive CT Power (China)-Computed Tomography X-Ray System Model: 728148
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0951-2023·2023-08-09

    FDA recalls dilTIAZem IV bags due to sterility assurance concerns

    Central Admixture Pharmacy Services is recalling 2,260 dilTIAZem IV bags nationwide because validation data for the decontamination process is lacking. Affected lots expire between July and August 2023.

    Product
    dilTIAZem 125mg/125mL (1 mg/mL), added to dextrose 5%, IV Bag, RX only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Phoenix, AZ 85043, NDC: 72196-6054-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0983-2023·2023-08-09

    FDA Recalls Oxytocin IV Bags Due to Sterility Assurance Concerns

    Central Admixture Pharmacy Services is recalling 463 bags of oxytocin IV solution nationwide due to inadequate validation data for sterilization processes. The product may not meet FDA sterility standards required for injectable medications.

    Product
    oxyTOCIN, 20 units added to dextrose 5%/lactated ringers 1000 mL, IV Bag, Rx Only, This drug was repacked by CAPS, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-6031-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1072-2023·2023-08-09

    Fentanyl-bupivacaine injectable drug recalled due to sterility concerns

    Central Admixture Pharmacy Services is recalling 896 bags of fentanyl-bupivacaine injectable solution nationwide due to lack of sterility assurance. The FDA Class II recall affects compounded pain medication lacking adequate sterilization validation.

    Product
    fentaNYL 2 mcg/mL and bupivacaine 0.125% PF in 0.9% sodium chloride / Total Volume = 250 mL, Total fentaNYL 500 mcg/250 mL, bag, Rx only, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC 71286-2082-2
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1025-2023·2023-08-09

    Cardioplegia Solution Recalled Due to Sterility Assurance Deficiency

    Central Admixture Pharmacy Services recalls Leesburg Cardioplegia Solution due to inadequate sterilization validation. The recall affects 36 bags distributed nationwide.

    Product
    CARDIOPLEGIA SOLUTION, LEESBURG CARDIOPLEGIA, IV Bag, Total Volume = 1030.2 mL, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0218-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1007-2023·2023-08-09

    Neonatal TPN Starter Bag Recalled Due to Sterility Assurance Issues

    Central Admixture Pharmacy Services is recalling a neonatal IV nutrition bag due to lack of sterility assurance. The recall affects 156 bags of the product distributed nationwide.

    Product
    Neonatal TPN Starter Bag, Amino Acids (trophamine) 3.5%/Dextrose 10% with CALCIUM, total volume = 250mL, IV Bag, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043,NDC: 72196-0407-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1069-2023·2023-08-09

    Injectable Fentanyl-Bupivacaine Mixture Recalled for Sterility Validation Failure

    Central Admixture Pharmacy Services recalls 295 bags of injectable fentanyl-bupivacaine solution nationwide because the sterilization process lacked proper validation documentation.

    Product
    fentaNYL 2 mcg/mL and bupivacaine 0.0625% PF in 0.9% sodium chloride, Total Volume = 250 mL, Total fentaNYL 500 mcg/250 mL, 250 mL bag, Rx only, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC 71286-2081-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1070-2023·2023-08-09

    Fentanyl and Bupivacaine Injectable Recalled for Sterility Concerns

    Central Admixture Pharmacy Services is recalling 1,114 bags of fentanyl and bupivacaine injectable due to lack of validation data for sterilization. The product was distributed nationwide.

    Product
    fentaNYL 2 mcg/mL and bupivacaine 0.125% PF in 0.9% sodium chloride, Total Volume = 100 mL, Total FentaNYL 200 mcg/100 mL, 100 mL bag, Rx only, CAPS, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC 71286-2082-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0957-2023·2023-08-09

    Epinephrine IV Bags Recalled Due to Unvalidated Sterility Process

    Central Admixture Pharmacy Services is recalling 333 units of epinephrine 2 mg in dextrose 5% IV bags because validation data for sterilization procedures is lacking, raising concerns about product sterility assurance.

    Product
    EPINEPHrine, 2 mg added to dextrose 5% 250mL, Concentration = 8 mcg/mL, IV Bag, Rx Only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Phoenix, AZ 85043, NDC: 72196-6030-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0980-2023·2023-08-09

    Neonatal TPN Starter Bags Recalled Due to Sterility Validation Concerns

    Central Admixture Pharmacy Services recalled 52 neonatal TPN starter bags nationwide due to lack of validation data for sterilization processes, raising concerns about sterility assurance.

    Product
    Neonatal TPN Starter Bag, Amino Acids (trophamine) 6%/Dextrose 10% with low calcium and HEPARIN, IV Bag, Total Volume = 250mL, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0430-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0993-2023·2023-08-09

    Neonatal IV Nutrition Bags Recalled Due to Sterility Assurance Defect

    Central Admixture Pharmacy Services is recalling 188 neonatal TPN bags nationwide because sterility assurance cannot be guaranteed. Validation data for decontamination cycles is lacking.

    Product
    Neonatal TPN Starter Bag, Amino Acids (trophamine) 2%/Dextrose 10% with CALCIUM and HEPARIN, total volume = 250mL, IV Bag, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0416-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1024-2023·2023-08-09

    Cardioplegia solution IV bags recalled for lack of sterility assurance

    Central Admixture Pharmacy Services is recalling 308 bags of cardioplegia solution nationwide due to lack of assurance of sterility and insufficient validation data for decontamination cycles.

    Product
    CARDIOPLEGIA SOLUTION, 48 mEq K, Induction 4:1 in Ringer's, High Potassium, IV Bag, total volume = 522.8 mL, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0206-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0961-2023·2023-08-09

    Phenylepherine IV bags recalled due to sterility assurance concerns

    Central Admixture Pharmacy Services is recalling over 8,300 phenylepherine IV bags nationwide because sterilization procedures were not adequately validated. Sterility cannot be assured for the affected units.

    Product
    PHENYLephrine 20mg/250ml added to 0.9% sodium chloride, IV Bag, Rx Only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Phoenix, AZ 85043, NDC: 72196-7025-1.
    Category
    Drug
    Distribution
    Distributed nationwide