Most US product recalls have nationwide distribution — the manufacturer ships into every state and the recall sweeps the same way. We include those in this listing because they affect Arkansas consumers even though the source notice doesn’t name the state. State-specific recalls are usually for products with regional distribution (a regional dairy, a local store brand) or where the agency was able to narrow the affected shipments to specific destinations.

If you’re checking whether a recall affects your purchase, the recall detail page lists the exact production lot codes, UPCs, and best-by dates. Match those against your package — distribution scope is a starting filter, not the final answer.

9426–9450 of 20189

  • HighFDA (Devices)·Z-1532-2024·2024-04-24

    Cook Coons Taper Dilators recalled due to low packaging seal strength

    Cook Incorporated is recalling 4,856 Coons Taper Dilators because packaging may have low seal strength, compromising device sterility. These percutaneous dilators are used in vascular and non-vascular procedures and are distributed worldwide.

    Product
    Dilator - Coons Taper - Used for dilating puncture sites or catheter tracts for percutaneous placement of devices for vascular and non-vascular applications such as in the venous, arterial, biliary and renal systems. REFERENCE PART NUMBER (RPN)/ORDER NUMBER (GPN): 1) JCD10.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0447-2024·2024-04-24

    Specialty Process Labs Recalls Thyroid USP Drug Ingredient for Failed Stability

    Specialty Process Labs is recalling Thyroid, USP, a pharmaceutical ingredient used in drug manufacturing, due to failed stability specifications. Seven lots distributed nationwide are affected.

    Product
    S.P Labs, Thyroid, USP, Rx only, For Manufacturing, Processing or Repackaging Use only, Specialty Process Labs, Phoenix, AZ, NDC #'s a) 81305-100-01, b)81305-100-02, c)81305-100-03
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1529-2024·2024-04-24

    Gastrointestinal Suture Anchor Recalled Due to Packaging Seal Defect

    Cook Incorporated is recalling the Entuit Secure Adjustable Gastrointestinal Suture Anchor Set due to packaging that may have insufficient seal strength, potentially compromising device sterility. The recalled lot is distributed worldwide.

    Product
    Entuit Secure Adjustable Gastrointestinal Suture Anchor Set - Intended for anchoring the anterior wall of the stomach to the abdominal wall prior to introduction of interventional catheters. REFERENCE PART NUMBER (RPN): GIAS-SRM-ADJ-2 ORDER NUMBER (GPN): G35562
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1591-2024·2024-04-24

    Conformis Identity Imprint PS Tibial Tray Size 4 Packaging Error

    Conformis is recalling Identity Imprint PS Tibial Tray Size 4 implants due to a packaging error where Size 5 components were placed in Size 4 boxes with incorrect lot numbers.

    Product
    Identity Imprint PS Tibial Tray Size 4: Lot 540287
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1571-2024·2024-04-24

    Philips MRI Systems: Patient support table floor plate installation defect

    Philips is recalling 448 Ingenia Elition X MRI systems worldwide due to potentially incorrect installation of the patient support table floor plate, which could compromise structural integrity.

    Product
    Ingenia Elition X, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1583-2024·2024-04-24

    Philips MRI System Patient Support Table Installation Defect Recall

    Philips recalls 25 Intera 1.5T R11 MRI systems due to potential incorrect installation of the patient support table floor plate, which may affect patient safety during device operation.

    Product
    Intera 1.5T R11, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1544-2024·2024-04-24

    Neria Soft Infusion Sets recalled due to incorrect instruction manual

    Unomedical A/S is recalling 10,770 units of Neria Soft Infusion Sets because certain lots were shipped with incorrect instructions for use. The wrong instruction manual for Rest of World markets was included instead of the FDA-approved US version.

    Product
    Neria Soft Infusion Set, Product Code 507302, intravascular administration set
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1588-2024·2024-04-24

    Magnetic Resonance System Patient Support Table Floor Plate Installation Issue

    Philips is recalling the MR 7700 Magnetic Resonance System due to potential incorrect installation of the patient support table floor plate. The recall affects 26 units distributed worldwide.

    Product
    MR 7700, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1560-2024·2024-04-24

    Philips GYROSCAN T10-NT MRI Systems Patient Support Table Floor Plate Installation Issue

    Philips North America is recalling GYROSCAN T10-NT MRI systems due to potential incorrect installation of the patient support table floor plate. Affected units should be verified for proper installation.

    Product
    GYROSCAN T10-NT, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1538-2024·2024-04-24

    Masimo Rad-G Pulse Oximeter automatic power cycling may cause monitoring loss

    Masimo Rad-G pulse oximeters may unexpectedly power off and on, potentially losing monitoring capability. About 4978 units affected worldwide.

    Product
    Masimo Rad-G, Pulse Oximeter (W/Patient Cable), REF:9849, Rx Only,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1575-2024·2024-04-24

    Philips MRI Patient Support Table Floor Plate May Be Incorrectly Installed

    Philips is recalling 347 Intera 1.5T MRI systems worldwide because the patient support table floor plate may be incorrectly installed, potentially compromising patient support stability during use.

    Product
    Intera 1.5T, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1525-2024·2024-04-24

    Chiba Biopsy Needles Recalled for Potential Sterility Compromise

    Cook Incorporated is recalling Chiba Biopsy Needles due to packaging that may have low seal strength, potentially compromising device sterility. The recall affects 6,178 units distributed worldwide.

    Product
    Chiba Biopsy Needle - Used for aspiration biopsy. REFERENCE PART NUMBER (RPN) ORDER NUMBER (GPN): 1) DCHN-18-10.0 G01559 2) DCHN-18-10.0-U G05040 3) DCHN-18-15.0 G00850 4) DCHN-22-10.0 G00852 5) DCHN-22-10.0-U G03978 6) DCHN-22-15.0 G00012 7) DCHN-22-15.0-U G03314 8)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1562-2024·2024-04-24

    MRI Patient Support Table Floor Plate May Be Incorrectly Installed

    Philips GYROSCAN T5-NT MRI systems may have an incorrectly installed patient support floor plate. Affected units should be inspected to ensure proper installation.

    Product
    GYROSCAN T5-NT, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1531-2024·2024-04-24

    Dilators With AQ Hydrophilic Coating recalled due to packaging seal defects

    Cook Incorporated is recalling 1,493 Dilators With AQ Hydrophilic Coating due to packaging that may not maintain proper seal strength, potentially compromising device sterility.

    Product
    Dilator With AQ Hydrophilic Coating - Intended to be used for dilating puncture sites or catheter tracts for percutaneous placement of devices for vascular and non-vascular applications such as in the venous, arterial, biliary and renal systems. REFERENCE PART NUMBER (RPN)/ORD
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·24207·2024-04-24

    Sant and Abel Children's Pajama Sets Recalled for Burn Hazard

    Sant and Abel is recalling about 935 children's two-piece pajama sets because they fail to meet federal flammability standards for children's sleepwear, posing a burn hazard. No injuries have been reported.

    Product
    Sant and Abel Children's Two-Piece Pajama Sets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1595-2024·2024-04-24

    SW Bari Lift & Transfer Device Recalled Due to Weight and Safety Defects

    Raye's Inc. is recalling the SW Bari Lift & Transfer (Model 38060000) due to two critical defects: it cannot safely support its maximum rated weight, and it lacks a safety mechanism to prevent falls during a single equipment failure.

    Product
    SW Bari Lift & Transfer, Model Number 38060000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1577-2024·2024-04-24

    Philips Intera 1.5T MRI Patient Support Table Floor Plate Installation Defect

    Philips is recalling 46 units of the Intera 1.5T Achieva Nova MRI system due to improper installation of the patient support table floor plate. The defect may compromise patient safety during use.

    Product
    Intera 1.5T Achieva Nova, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1565-2024·2024-04-24

    Philips Ingenia MRI System Patient Support Table Floor Plate Installation Defect

    Philips is recalling 135 Ingenia 1.5T S MRI systems worldwide because the patient support table floor plate may be incorrectly installed, creating a potential safety risk to patients and staff.

    Product
    Ingenia 1.5T S, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1586-2024·2024-04-24

    MRI System Patient Support Table Floor Plate May Be Incorrectly Installed

    Philips Intera CV MRI systems may have an incorrectly installed patient support table floor plate. Eight units have been recalled due to this installation defect.

    Product
    Intera CV, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1590-2024·2024-04-24

    MRI system patient support table floor plate installation defect

    Philips MRI systems may have an incorrectly installed patient support table floor plate, creating a potential stability risk during patient imaging.

    Product
    SmartPath to dStream for XR and 3.0T, Magnetic Resonance System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1545-2024·2024-04-24

    CryoValve SG Heart Valve Recalled for Staphylococcus aureus Contamination

    Artivion is recalling one CryoValve SG cryopreserved heart valve contaminated with Staphylococcus aureus, detected during organ donation screening. No illnesses have been reported.

    Product
    CryoValve SG Cryopreserved Pulmonary Human Heart Valve
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1536-2024·2024-04-24

    Masimo Rad-G Pulse Oximeter Recall: Potential Automatic Power Loss

    Masimo Corporation is recalling 443 Rad-G pulse oximeters that may automatically power off and on, interrupting patient monitoring. Affected units are distributed worldwide.

    Product
    Masimo Rad-G, Pulse Oximeter with temperature (W/Sensor), REF:9210, Rx Only,
    Category
    Medical Device
    Distribution
    Distributed nationwide