The Recall Desk

State

Alaska product recalls

72,992 recalls have nationwide distribution and so reach Alaska. 1,764 additional recalls listed Alaska specifically in their distribution scope.

What the numbers show

Total
1,764
Critical
118
Severe
350
Most recent
2026-09-09

Of the 1,764 recalls naming Alaska we have scored against our rubric, 118 (7%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 350 (20%) are Severe.

These figures cover only the 1,764 recalls whose distribution notice names Alaska specifically. The 72,992 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

8051–8075 of 74756

  • SevereFDA (Devices)·Z-0764-2025·2025-01-22

    Medline Fluid Delivery Sets incorrectly assembled with wrong drip chamber

    Medline fluid delivery sets were assembled with a macro drip chamber instead of the required micro drip chamber, delivering three times more fluid per drop and risking patient fluid overload.

    Product
    Medline Fluid Delivery Set with Drip Chamber: 1) FDS,135,CHMN,W/F,MLL,RC(2),PG, Item Number 99000069; 2) FDS,135,NV,MICRO-CHAMBER,W/FILTER,BLUE, Item Number 949000222; 3) FDS,135,NV,MICRO-CHAMBER,W/FILTER,GREEN, Item Number 949000224; 4) FDS,135,NV,MICRO-CHAMBER,W/FILTER,RE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0821-2025·2025-01-22

    Neo-Tee Resuscitator Spring Defect May Impair Pediatric Ventilation

    Mercury Medical is recalling the Neo-Tee T-Piece Resuscitator due to an undersized spring in the circuit flow controller that may prevent reaching proper pressure ranges, potentially impairing emergency ventilation.

    Product
    Neo-Tee T-Piece Resuscitator, for pediatric emergency respiratory support, Part: 1050805, 1050808, 1050809, 1050810, 1050811, 1050814, 1050832, 1050839, 1050840, 1050841, 1050842
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0826-2025·2025-01-22

    CRT-P Pacemakers Recalled for Potential Safety Mode Initiation Risk

    Boston Scientific's ACCOLADE Family pacemakers, including VALITUDE CRT-P models, are recalled due to battery impedance defects that could trigger unintended Safety Mode during normal operation.

    Product
    VALITUDE CRT-P, EL (Model Number U125) and EL MRI (Model Number U128)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0905-2025·2025-01-22

    Olympus MAJ-891 Forceps Recalled for Potential Biomaterial Retention During Reprocessing

    Olympus recalls the MAJ-891 endoscope forceps/irrigation plug nationwide because improper reprocessing may leave biomaterial inside the device, creating a contamination risk.

    Product
    Olympus MAJ-891 Forceps/Irrigation Plug (Isolated Type). Model/Catalog Number: MAJ-891. This instrument is designed to be attached to the instrument channel port of Olympus endoscopes to allow both irrigation and the use of endo-therapy accessories.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0829-2025·2025-01-22

    Impella RP Heart Pump Recalled Due to Optical Sensor Damage Risk

    Abiomed is recalling 1,560 units of the Impella RP with SmartAssist pump due to risk of optical sensor damage from device interactions. Damaged sensors may cause temporary or permanent pump malfunction.

    Product
    Impella RP with SmartAssist; Product Number: 0046-0035;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0765-2025·2025-01-22

    Medline Fluid Delivery Sets Recalled Due to Assembly Error

    Medline Fluid Delivery Sets were incorrectly assembled with macro drip chambers instead of required micro drip chambers. The macro chamber delivers three times more fluid per drop, creating a risk of dosing errors.

    Product
    Medline Fluid Delivery Set with Drip Chamber: 1) MTO,135,YELLOW,MICRO,SPK-MAIMONIDES, Item Number: 60130527; 2) MTO,ANGIO,DOUBLE,SPIKE,KIT,KENNEDY HLTH, Item Number: 65111341; 3) MTO,ANGIO,SINGLE,SPIKE,KIT, Item Number: 65232486; 4) MTO,ANGIO,SINGLE,SPIKE,KIT,GOOD,SAM, Item
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0885-2025·2025-01-22

    Welch Allyn Life2000 Ventilator Battery Charger May Cause Device Inoperability

    Baxter Healthcare is recalling 946 Welch Allyn Life2000 ventilators due to a battery charger defect that can trigger an alarm and render the device inoperable.

    Product
    Welch Allyn, Inc., Life2000 Ventilation System, REF BT-20-0002A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0886-2025·2025-01-22

    Welch Allyn Life2000 Ventilator Battery Charger Malfunction Recall

    Baxter Healthcare Corporation is recalling Welch Allyn Life2000 Ventilation Systems due to a battery charger malfunction that triggers an alarm and renders the ventilator inoperable.

    Product
    Welch Allyn, Inc., Life2000 Ventilation System, REF BT-20-0002AP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0827-2025·2025-01-22

    VISIONIST CRT-P Pacemakers Recalled Due to Battery Impedance Risk

    Certain VISIONIST CRT-P pacemakers with latent high battery impedance may initiate Safety Mode unexpectedly during normal operations. Manufactured before September 2018, 156,329 units were distributed worldwide.

    Product
    VISIONIST CRT-P, EL (Model Number U225 and U226) and EL MRI (Model Number U228)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0824-2025·2025-01-22

    ESSENTIO DR Pacemakers May Malfunction Due to Battery Impedance Issue

    Boston Scientific is recalling certain ESSENTIO DR Pacemakers manufactured before September 2018 due to latent battery impedance that may cause Safety Mode malfunction during normal operations.

    Product
    ESSENTIO DR Pacemaker, SL (Model Number L101, SL MRI (Model Number L111), EL (Model Number L121), and EL MRI (Model Number L131)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0822-2025·2025-01-22

    ACCOLADE DR Pacemakers Recalled for Unintended Safety Mode Activation

    Boston Scientific is recalling ACCOLADE DR Pacemakers built before September 2018 due to risk of unintended Safety Mode activation caused by battery impedance issues. The devices may enter Safety Mode during normal telemetry operations.

    Product
    ACCOLADE DR Pacemaker, SL (Model Number L301), SL MRI (Model Number L311), EL (Model Number L321), and EL MRI (Model Number L331)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0831-2025·2025-01-22

    Dialysis Blood Circuit May Cause Excessive Fluid Removal

    The AquaFlexFlow UF 500 Plus blood circuit may malfunction and remove excessive fluid from patients, causing a dangerous drop in blood volume. This risk is especially dangerous for pediatric patients.

    Product
    nuwellis AquaFlexFlow UF 500 Plus, REF 114156, Catalog Number A06163, extracorporeal blood circuit which is used with the Aquadex SmartFlow or Aquadex FlexFlow System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0200-2025·2025-01-22

    Systane Lubricant Eye Drops Recalled for Non-Sterility Risk

    Alcon Research is voluntarily recalling Systane Lubricant Eye Drops, Ultra PF, due to non-sterility concerns. The recall affects 55,960 boxes distributed nationwide.

    Product
    Systane Lubricant Eye Drops, Ultra PF, Sterile, 25 Vials (0.7mL Each), Manufactured for: Alcon Laboratories, Inc. Forth Worth, TX 76134
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0961-2025·2025-01-22

    VerifyNow P2Y12 Platelet Reactivity Test distributed without FDA market clearance

    Accriva Diagnostics distributed the VerifyNow P2Y12 Platelet Reactivity Test (Lot WL1145) without required FDA clearance. Healthcare professionals could use the unapproved test to guide treatment decisions for P2Y12 inhibitor therapy.

    Product
    VerifyNow P2Y12 Platelet Reactivity Test, REF: 85064
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0954-2025·2025-01-22

    Surgical instrument kits recalled for potential sterile packaging defects

    Sklar Instruments is recalling 41,850 units of ECONO STERILE surgical procedure kits due to packaging defects that may compromise the sterile barrier, affecting multiple clamp and hemostat models used in general orthopedic surgery.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE OLSEN-HEG NH SMO DEL 5.5STER25, Model Number 96-2352A; 2) ECONO STERILE HALSEY NH SERR 5" STRL CS/25, Model Number 96-2353; 3) ECONO STERILE OLSEN-HEGAR NH 5.5" STRL CS/25, Model Number 96-2355A; 4) ECO
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0952-2025·2025-01-22

    Orthopedic Surgery Kits Recalled for Potential Sterile Barrier Packaging Defects

    Sklar Instruments is recalling ECONO STERILE LEMPERT BONE RONG orthopedic surgery kits due to packaging defects that may compromise sterility. The affected kits (Model 96-4780A, Lot HSI) were distributed nationwide.

    Product
    ECONO STERILE medical procedure kits labeled as: ECONO STERILE LEMPERT BONE RONG 6.25" STER25, Model Number 96-4780A; orthopedic surgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0918-2025·2025-01-22

    Portrait Core Services Software Loss of Patient Monitoring After 425 Days

    A software issue in GE's Portrait Core Services medical device software causes loss of patient monitoring capability in the Portrait Central Viewer Application after 425 days of continuous operation.

    Product
    Portrait Core Services, a set of software services that enable the communication and interaction of the Portrait Mobile Monitoring Solution components and will integrate into existing healthcare facility infrastructure and clinical information systems, Model CSSXB
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0946-2025·2025-01-22

    Gynecological dilator kits recalled for potential sterile barrier compromise

    Sklar Instruments is recalling ECONO STERILE gynecological dilator kits nationwide due to packaging issues that may breach the sterile barrier, potentially affecting product safety.

    Product
    ECONO STERILE medical procedure kits labeled as: 1) ECONO STERILE HEGAR DILATOR 11&12MM STRLCS25Model Number 96-0960; 2) ECONO STERILE HEGAR DILATOR 9&10MM STRL CS25Model Number 96-0961; 3) ECONO STERILE HEGAR DILATOR 7&8MM STRL CS25Model Number 96-0962; 4) ECONO STERILE
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0862-2025·2025-01-22

    Surgical Retractor Grip Cables May Fray or Break During Use

    Intuitive Surgical is recalling 738 units of the 8MM Atrial Retractor (Model 470246) due to reports of frayed or broken grip cables on reusable instruments. The defect could compromise instrument performance during surgical procedures.

    Product
    8MM,ATRIAL RETRACTOR SHORT RIGHT,IS4000¿ REF 470246
    Category
    Medical Device
    Distribution
    52 states
  • HighFDA (Devices)·Z-0845-2025·2025-01-22

    X-Flow Prostatectomy Catheter Recalled for Possible Sterility Defect

    Coloplast is recalling 36,369 X-Flow prostatectomy catheters due to a possible sterility issue detected at its manufacturing facility.

    Product
    X-Flow prostatectomy catheter, Device Reference Numbers AB6022, AB6024, AB6118, AB6120, AB6122, AB6124, AB6220, AB6222, AB6224, AB6318, AB6320, AB6322, AB6324, AB6418, AB6420, AB6422, AB6424, AB6522, AB6524, AB6A18, AB6A20, AB6A22, AB6A24, AB6C18, AB6C20, AB6C22, and AB6C24.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0908-2025·2025-01-22

    Cardinal Health Presource Surgical Kits Recalled for Endotoxin Contamination

    Cardinal Health is recalling Presource surgical kits due to potential endotoxin contamination in non-sterile surgical strips and patties. No illnesses have been reported.

    Product
    Cardinal Health Presource Kits: 1) KIT,PLASTIC FLAP,Catalog Number PGHDOT951; 2) KIT,ORP PLASTIC FLAP,Catalog Number PGHDOT952; 3) KIT,ORP PLASTIC FLAP,Catalog Number PWHDOT910; 4) KIT,ORP PLASTIC FLAP,Catalog Number PWHDOT911; 5) KIT,ORP PLASTIC FLAP,Catalog Number PWHD
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0901-2025·2025-01-22

    Digoxin Test Slides May Report Inaccurately Due to Hemoglobin Interference

    QUIDEL ORTHO is recalling VITROS DGXN test slides because hemoglobin can interfere with digoxin measurements at lower-than-expected levels, potentially causing inaccurate test results.

    Product
    Brand Name: VITROS Chemistry Products Product Name: VITROS Chemistry Products DGXN Slides Model/Catalog Number: 8343386 Software Version: Not Applicable Product Description: The VITROS DGXN Slide is a multilayered, analytical element coated on a polyester support. Digoxi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0962-2025·2025-01-22

    Olympus LithoCrushV Mechanical Lithotriptor Recalled for Distal Tip Tearing Risk

    Olympus Corporation recalls the LithoCrushV Single Use Mechanical Lithotriptor due to potential distal tip tearing during endoscopic procedures. The FDA Class II recall affects 989 units distributed nationwide.

    Product
    LithoCrushV Single Use Mechanical Lithotriptor V. Model Number: BML-V442QR-30. Single Use Mechanical Lithotriptor V used with Olympus endoscope for crushing calculi inside the bile duct.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0940-2025·2025-01-22

    ECONO STERILE Procedure Kits Recalled for Sterile Barrier Breach Risk

    Sklar Instruments is recalling ECONO STERILE medical procedure kits (Model 96-4921A) due to packaging issues that may result in a breach of the sterile barrier. The kits should not be used.

    Product
    ECONO STERILE medical procedure kits labeled as: ECONO STERILE BLAKE GALLSTONE FCP CVD 8"CS25, Model Number 96-4921A
    Category
    Medical Device
    Distribution
    Distributed nationwide