The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

16501–16525 of 114192

  • HighFDA (Devices)·Z-1606-2024·2024-05-01

    Alcon Custom Paks Surgical Procedure Packs recalled for cannula defects

    Alcon is recalling Custom Paks Surgical Procedure Packs containing Oasis 27Ga Chang Hydrodissection Cannulas due to complaints of particulates, residue, occlusions, and bent tips in sterile cannulas used in ophthalmic surgery.

    Product
    Various Alcon Custom Paks Surgical Procedure Pack containing Oasis 27Ga Chang Hydrodissection Cannulas. These Custom Paks are surgical procedure packs used by ophthalmic surgeons in a variety of ophthalmic surgeries. The Custom Pak is a collection of various ophthalmic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1620-2024·2024-05-01

    Pedicle Screw Heads Recalled Due to Cross-Threading Risk During Surgery

    SeaSpine's Mariner RDX MIS pedicle screw heads may have partial threading that causes cross-threading at the screw head interface during implant installation. Affected units distributed in CA, FL, CO, and TX.

    Product
    Mariner RDX MIS Polyaxial Head, REF: MX1-001010, part of Mariner RDX MIS Alpha Instruments and Implants, REF: AMRDXMIS, which are pedicle screw systems.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1630-2024·2024-05-01

    Hip prosthesis shells recalled for manufacturing deburring defect

    Howmedica Osteonics Corp. is recalling TRIDENTII PSL CLUSTER52E hip prostheses with excessive deburring on the acetabular shell edge, which could affect implant stability. Three units were distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER52E- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-52E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1632-2024·2024-05-01

    Hip replacement acetabular shells recalled for deburring defect

    Howmedica is recalling hip replacement acetabular shells that may have excessive deburring, resulting in a smooth surface on the shell edge. The recall affects devices distributed nationwide and internationally.

    Product
    TRIDENTII PSL CLUSTER64H- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-64H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1628-2024·2024-05-01

    Hip implant recalled for acetabular shell deburring defect

    Howmedica Osteonics Corp. is recalling TRIDENTII PSL CLUSTER48D hip implants (Lot 16311453) due to excessive deburring on the acetabular shell edge, a manufacturing defect.

    Product
    TRIDENTII PSL CLUSTER48D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-48D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0590-2024·2024-05-01

    Tissue Processor Recall: HistoCore PEGASUS May Produce Damaged Specimens

    Leica is recalling 98 HistoCore PEGASUS automated tissue processors due to a protocol configuration error that can produce poorly processed or damaged biopsy specimens.

    Product
    Leica HistoCore PEGASUS (PROCESSOR, TISSUE, AUTOMATED)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1604-2024·2024-05-01

    Redux Electrolyte Creme Recalled for Low Viscosity Defect

    Parker Laboratories is recalling Redux Electrolyte Creme, a highly conductive medical electrolyte product, due to demonstrated low viscosity.

    Product
    Redux Electrolyte Creme, Product Ref. 66-04. Highly conductive electrolyte creme.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V310000·2024-05-01

    Jayco Terrain and Entegra Launch Motorhomes Recalled for Wiring Chafing Hazard

    Jayco and Entegra recall certain 2023-2024 motorhomes with a wiring harness that may chafe against the drive shaft, causing short circuit and risking loss of steering, braking, and drive power, plus fire.

    Product
    ENTEGRA — ENTEGRA, JAYCO LAUNCH, TERRAIN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1634-2024·2024-05-01

    Dialysis Catheters Recalled Due to Missing Heparin Coating

    Certain Palindrome Precision HSI dialysis catheters do not have the heparin coating indicated on the label, which could reduce their protective benefits during dialysis procedures.

    Product
    Palindrome Precision HSI Chronic Catheter Sport Pack 14.5 Fr/Ch (4.8mm) x 19 cm (Symmetrical Tip, Heparin Coating, Silver Ion Sleeve and Tal VenaTrac Stylet- Intended for acute and chronic hemodialysis, apheresis, and infusion. Model Number (CFN): 8888119369P
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1625-2024·2024-05-01

    TRIDENTII HEMI Hip Implant Acetabular Shell Deburring Defect Recall

    Howmedica Osteonics is recalling the TRIDENTII HEMI CLUSTER54E hip implant due to excessive deburring on the acetabular shell edge that may affect implant performance. The recall involves 225 units distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER54E- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-54E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1635-2024·2024-05-01

    Palindrome Precision H Chronic Catheter Kit may lack labeled heparin coating

    Covidien is recalling 878 units of Palindrome Precision H Chronic Catheter Kits that may lack the heparin anticoagulant coating indicated on the label, potentially reducing clot prevention during hemodialysis.

    Product
    Palindrome Precision H Chronic Catheter Kit 14.5 Fr/Ch (4.8mm) x 23 cm (Symmetrical Tip, Heparin Coating and Tal VenaTrac Stylet- Intended for acute and chronic hemodialysis, apheresis, and infusion. Model Number (CFN): 8888145044CP
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1607-2024·2024-05-01

    Vanguard Knee System Tibial Bearing Recalled for Manufacturing Damage

    Biomet is recalling the Vanguard Knee System AS Tibial Bearing (Model 189082) due to possible damage during manufacturing. Affected units were distributed worldwide including the United States.

    Product
    Vanguard Knee System AS Tibial Bearing / DCM ArCom, 12 MM X 75 MM; Model Number 189082. The product is placed into a foil pouch with protective packaging in the form of a polyurethane bag, and sealed closed (inner barrier). The inner barrier is then placed into a PETG tray and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·24V308000·2024-05-01

    2024 Hyundai Kona electrical short can cause loss of drive power

    Hyundai is recalling 2024 Kona, Elantra, and Venue vehicles because an electrical short in the EGR valve can cause loss of drive power. Dealers will replace the assembly free of charge.

    Product
    HYUNDAI — HYUNDAI VENUE, ELANTRA, KONA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0475-2024·2024-05-01

    Minolira extended-release tablets recalled due to discontinued quality assurance program

    EPI Health is recalling 5,664 bottles of minolira tablets because the manufacturer discontinued its quality assurance program. Affected lots include T2201700 and T2201701, distributed nationwide.

    Product
    minolira (minocycline hydrochloride) extended-release tablets, 135mg 30-count Bottle, Rx Only, Mfg by: Dr Reddy's Laboratories Limited, INDIA, Manufactured for: EPI Health, LLC, Charleston, SC 29403, NDC 71403-102-30.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0471-2024·2024-05-01

    Prescription respiratory drug recalled for short fill in unit-dose vials

    Cipla USA recalls Ipratropium Bromide and Albuterol Sulfate inhalation solution due to short fill in unit-dose vials. Some vials contain less medication than labeled, affecting dosage.

    Product
    IPRATROPIUM BROMIDE AND ALBUTEROL SULFATE — IPRATROPIUM BROMIDE AND ALBUTEROL SULFATE (IPRATROPIUM BROMIDE AND ALBUTEROL SULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1621-2024·2024-05-01

    Hip implant acetabular shell manufacturing defect recall affects patients

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER44B hip implants due to excessive deburring on the acetabular shell edge. The recalled lot was distributed nationwide and internationally.

    Product
    TRIDENTII HEMI CLUSTER44B- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-44B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1205-2024·2024-05-01

    Kowalski Jack's Potato Salad recalled for undeclared egg allergen

    Home Style Foods is recalling Kowalski Simply Sides Jack's Potato Salad for containing undeclared egg, which poses a risk to consumers with egg allergies.

    Product
    Kowalski Simply Sides - Jack's Potato Salad, 16oz. plastic tub, UPC: 754721282701. 6 retail tubs per wholesale case.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Devices)·Z-1619-2024·2024-05-01

    Lead Wire Replacement Parts Recalled for Sheath Damage and Treatment Signal Loss

    EBI, LLC is recalling 594 units of 48-inch lead wire replacement parts (part number 1067724-4) due to sheath damage that prevents therapeutic signals from reaching treatment electrodes.

    Product
    48" Lead Wires, Replacement Part Number: 1067724-4
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1629-2024·2024-05-01

    Hip replacement acetabular shell recalled for excessive deburring

    Howmedica Osteonics is recalling TRIDENTII PSL CLUSTER50D acetabular shells for hip replacements due to excessive deburring resulting in smooth edges on the shell.

    Product
    TRIDENTII PSL CLUSTER50D- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 742-11-50D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1176-2024·2024-05-01

    Teriyaki Salmon Recalled Due to Mislabeling as Chicken

    Taylor Farms Southwest is recalling 6 packages of Ready Meals Teriyaki Salmon that were mislabeled as Teriyaki Chicken, posing a risk for consumers with fish allergies.

    Product
    Ready Meals Teriyaki Salmon W Rice 13.5OZ TRAY BLK&GOLD ALUM 22OZ with Plastic Lid #81061425 UPC: 002113010092 Sell Thru 04/12/24 LOT TFSW095A
    Category
    Food
    Distribution
    0 states
  • HighFDA (Devices)·Z-1627-2024·2024-05-01

    Hip Implant Acetabular Shell May Have Excessive Deburring Manufacturing Defect

    Howmedica Osteonics Corp. is recalling TRIDENTII HEMI CLUSTER66H hip implants because the acetabular shell may have excessive deburring, creating a smooth surface on the edge of the shell.

    Product
    TRIDENTII HEMI CLUSTER66H- Indicated for use in primary and revision patients at high risk of hip dislocation Catalog Number: 702-11-66H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1600-2024·2024-05-01

    ACUSON Redwood 1.0 ultrasound displays incorrect cardiac measurement values

    The ACUSON Redwood 1.0 Diagnostic Ultrasound System may display the last measured cardiac value instead of the minimum or maximum value as configured, potentially leading to misdiagnosis or improper patient management.

    Product
    ACUSON Redwood 1.0 Diagnostic Ultrasound System, REF: 11503314, running software version VA10A to VA10G
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0473-2024·2024-05-01

    Cloderm Cream Recalled for Manufacturer Quality Assurance Program Discontinuation

    EPI Health is recalling Cloderm cream due to discontinuation of the manufacturer's quality assurance program. This may result in products that do not meet specifications for identity, strength, purity, or quality.

    Product
    Cloderm (clocortolone pivalate) Cream, 0.1%, Rx Only, For Topical Use Only, Net Wt 45g, Manufactured for: EPI Health, LLC, Charleston, SC 29403, NDC 71403-804-90
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1608-2024·2024-05-01

    NexGen CR-Flex Femoral Components Recalled for Bonding Defect

    Zimmer is recalling 5,546 units of NexGen CR-Flex Femoral Components due to a manufacturing defect where the fiber metal pad fails to bond properly to the substrate. Patients with these implants should contact their healthcare provider.

    Product
    NexGen CR-Flex Femoral Component, Size E and Size E Minus (E-). Component of the NexGen CR-Flex Porous Femur System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1603-2024·2024-05-01

    Proton Therapy System Recall: Safety Parameter Failures Risk Unintended Radiation

    IBA Proton Therapy System (PROTEUS 235) units recalled due to safety parameter failures that could prevent proper radiation control, risking unintended radiation exposure during cancer treatment.

    Product
    IBA Proton Therapy System - PROTEUS 235, PTS-10 versions, PTS-11 versions, and PTS-12 versions.
    Category
    Medical Device
    Distribution
    Distributed nationwide