The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

11051–11075 of 114059

  • HighFDA (Drugs)·D-0219-2025·2025-02-12

    Hydralazine Hydrochloride Tablets Recalled Due to Impurities and Degradation

    SKY Packaging recalls Hydralazine Hydrochloride 25 mg tablets nationwide due to failed quality specifications for impurities and degradation.

    Product
    HydrALAZINE Hydrochloride, 25 mg, 100 Unit Dose Tablets (10x10), USP, Rx only, Manufactured by Strides Pharma Science Ltd, Bengaluru, India, Distributed by McKesson by: McKesson Corporation dba SKY Packaging, TN 38141. NDC 63739-327-10
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0482-2025·2025-02-12

    Bavarian Paczki Recalled for Listeria Monocytogenes Contamination Risk

    FGF, LLC is recalling Bavarian Paczki (item 8201814) due to potential Listeria monocytogenes contamination. The recall affects 2,017,614 cases distributed nationwide in the US and Canada.

    Product
    item 8201814 BAVARIAN PACZKI 66x4OZ, NET WT 14.85 LB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0469-2025·2025-02-12

    Dierbergs Kitchen Mac & Cheese recalled for undeclared wheat allergen

    Dierbergs Markets recalls 298 packages of Mac & Cheese due to labeling errors that fail to disclose wheat allergens. The product was distributed to Missouri and Illinois retailers with a use-by date of 1/9/2025.

    Product
    Dierbergs Kitchen 16 oz Mac & Cheese packaged in a black plastic container with a clear plastic lid with a white label, The label states "Dierbergs Kitchen Homestyle Mashed Potatoes UPC 231220-006538"
    Category
    Food
    Distribution
    2 states
  • HighFDA (Devices)·Z-1110-2025·2025-02-12

    IntelliVue Patient Monitor MX550 May Fail to Alarm on Ventilator Disconnection

    Philips IntelliVue Patient Monitor MX550 units may fail to generate an alarm when a Hamilton ventilator is disconnected, creating a patient safety risk. The monitor could remain silent without alerting clinical staff.

    Product
    IntelliVue Patient Monitor MX550. Model Number: 866066
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1109-2025·2025-02-12

    IntelliVue Patient Monitor MX500 may fail to generate critical alarms

    Philips IntelliVue Patient Monitor MX500 units may fail to generate "No Device Data" alarms when a Hamilton ventilator disconnects, potentially delaying notification of loss of connectivity. 45 units distributed in the US and internationally.

    Product
    IntelliVue Patient Monitor MX500. Model Number: 866064
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Food)·F-0529-2025·2025-02-12

    FGF Vanilla Mini Cake Donut Rings Recalled for Listeria Contamination Risk

    FGF, LLC is recalling 2,017,614 cases of vanilla mini cake donut rings due to potential Listeria monocytogenes contamination. The affected product was produced on or before December 13, 2024, and distributed nationwide in the US and Canada.

    Product
    item 8202891 PLAIN VANILLA MINI CAKE DONUT RING BULK 240X1.25OZ, NET WT 16.88 LB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1043-2025·2025-02-12

    X-Ray imaging systems may allow radiation exposure beyond safety limits

    GE Medical Systems is recalling Definium 656HD and Discovery XR656HD X-Ray systems due to an Automatic Exposure Control defect that may allow radiation exposure to exceed intended safety limits.

    Product
    Definium 656HD & Discovery XR656HD (GTINs: 00840682138598, 00195278840226, 00840682136709). X-Ray imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0465-2025·2025-02-12

    FDA Recalls Greenwise Organic Pecan Halves for Undeclared Walnuts

    The FDA has recalled Greenwise Organic Pecan Halves (8-ounce bags) due to undeclared walnuts, a major allergen. The affected product was distributed in eight southeastern states.

    Product
    Greenwise Organic Pecan Halves 8 ounce, plastic printed package marked with lot # 18228 and with a best by date of April.23.2025 stamped on front UPC: 041415212336
    Category
    Food
    Distribution
    8 states
  • HighFDA (Devices)·Z-1085-2025·2025-02-12

    Finger entrapment hazard in Philips Allura fluoroscopy patient tables

    Philips is recalling AD7 and AD7X patient tables from Allura and Azurion fluoroscopy systems. During manual repositioning, fingers can become trapped between the guiding rails and tabletop, potentially causing injury.

    Product
    Allura Xper FD20/20 System Code: (1) 722038
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0490-2025·2025-02-12

    Frozen Persian Donuts Recalled Due to Listeria Contamination Risk

    FGF, LLC is recalling frozen Persian donuts nationwide due to potential Listeria monocytogenes contamination. Consumers should not consume affected products.

    Product
    item 8201841 GEN PERSIAN DONUT DGH FRZ 168x2OZ, NET WT 18.90 LB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0221-2025·2025-02-12

    Potassium Chloride Tablets Recalled for Failed Dissolution Specifications

    The FDA is recalling Potassium Chloride Extended-Release Tablets (10 mEq) distributed nationwide because they failed dissolution tests. This could affect how the medication is released in the body.

    Product
    POTASSIUM CHLORIDE — POTASSIUM CHLORIDE (POTASSIUM CHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1093-2025·2025-02-12

    Philips Azurion patient tables recalled for finger entrapment risk

    Philips is recalling Azurion 7 M12 and Allura patient tables used in medical imaging systems due to a finger entrapment hazard during manual repositioning. Operators and service personnel may suffer finger injury if fingers are caught between the tabletop and guiding rails.

    Product
    Azurion 7 M12 System Code: (1) 722078 (2) 722223 (3) 722233
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1044-2025·2025-02-12

    Medical X-Ray System Permits Bypass of Radiation Exposure Control

    GE Medical Systems' Discovery XR656HD X-Ray imaging systems can allow radiation exposures to exceed the Automatic Exposure Control limit without blocking further exposure. Approximately 3,149 units are affected worldwide, including 1,697 in the United States.

    Product
    Discovery XR656HD. X-Ray imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V081000·2025-02-12

    Volkswagen Atlas transmissions may have been manufactured incorrectly

    Volkswagen is recalling certain 2025 Atlas and Atlas Cross Sport vehicles because the transmission may have been manufactured incorrectly, which can result in a loss of drive power.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS CROSS SPORT, ATLAS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1095-2025·2025-02-12

    Hologic Rapid fFN Specimen Collection Tubes May Contain Incorrect Extraction Buffer Volumes

    Hologic Rapid fFN Specimen Collection Tubes from three lots may contain incorrect amounts of extraction buffer, potentially causing invalid test results or diagnostic errors in preterm delivery assessment.

    Product
    The Rapid fFN Specimen Collection Tube (PN: 71550-001) is a component of the Rapid fFN Specimen Collection kit (PN: 71738-001). The Collection Tube (PN: 71550-001) is manufactured by a third-party supplier, MML Diagnostics Packaging, and includes the transport tube, cap, and extr
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1101-2025·2025-02-12

    Dental implants recalled for manufacturing defect affecting sterile packaging

    Nobel Biocare recalled N1 TiUltra TCC dental implants due to a manufacturing defect that may puncture the sterile blister packaging. The defect is a sharp pin created during injection molding that could compromise product sterility.

    Product
    . Nobel Biocare N1 TiUltra TCC RP 4.0x9mm . Nobel Biocare N1 TiUltra TCC RP 4.0x11mm . Nobel Biocare N1 TiUltra TCC RP 4.0x13mm Nobel Biocare N1 TiUltra TCC implants are intended for use as an endosseous dental implant in the maxilla or mandible for anchoring or supporting
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1111-2025·2025-02-12

    Temporary Titanium Abutments May Fracture in Dental Implants

    DDS Lab temporary titanium abutments may have been installed in some dental implant restoration cases instead of definitive abutments. The components may fracture, risking restoration loosening, oral tissue injury, and aspiration.

    Product
    Temporary Titanium Abutments
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1078-2025·2025-02-12

    Philips AlluraXper Patient Tables Pose Finger Entrapment Risk

    Philips is recalling AD7 and AD7X patient tables used in Allura and Azurion fluoroscopy systems. Manual repositioning can trap fingers between the tabletop and rails, risking injury to operators and service personnel.

    Product
    AlluraXper FD10/10 System Code: (1) 722005 (2) 722011 (3) 722027
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0505-2025·2025-02-12

    FGF Twist Donuts Recalled Due to Listeria Contamination Risk

    FGF's Twist Donuts are being recalled nationwide in the US and Canada due to potential Listeria monocytogenes contamination. The recall affects approximately 2 million cases produced on or before December 13, 2024.

    Product
    item 8201868 GEN TWIST DONUT ZGT PFD 84x1.75 OZ, NET WT 12.93 LB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1115-2025·2025-02-12

    Beckman Coulter DxI 9000 immunoassay analyzer recalled for software-related motion errors

    Beckman Coulter is recalling 61 DxI 9000 immunoassay analyzers worldwide due to a software error causing tray gripper motion errors that result in intermittent hard stops and delays in patient test results.

    Product
    Beckman Coulter DxI 9000 Access Immunoassay Analyzer, catalog number C11137; in-vitro diagnostic instrument
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0512-2025·2025-02-12

    FGF LLC Recalls Unfilled Bismarck Donuts for Listeria Contamination Risk

    FGF LLC is recalling 2,017,614 cases of unfilled Bismarck donuts nationwide due to potential listeria monocytogenes contamination. Consumers should not consume the affected product.

    Product
    item 8201883 UNFLD BISMARK DONUT PFD 57x2.75OZ, NET WT 8.82 LB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1082-2025·2025-02-12

    Philips AlluraXper FD20 operating room surgical table finger entrapment risk

    Philips AlluraXper FD20 operating room tables can trap fingers during manual repositioning, risking injury. The hazard affects both operators and service personnel worldwide.

    Product
    AlluraXper FD20 Biplane OR Table System Code: (1) 722020 (2) 722025
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0500-2025·2025-02-12

    Just Baked Eclairs Recalled Nationwide Due to Listeria Contamination Risk

    FGF, LLC is recalling Just Baked Eclairs nationwide in the US and Canada due to potential Listeria monocytogenes contamination. All products produced on 12/13/24 or earlier are affected.

    Product
    item 8201863 JUST BAKED ECLAIRS 84x2.36 OZ, NET WT 12.39 LB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1102-2025·2025-02-12

    ECG cable shipped with incomplete cleaning and disinfection instructions

    Physio-Control is recalling 245 LIFEPAK 35 ECG cables (Lot 0224) because the shipped instructions do not include proper cleaning and disinfection procedures, creating potential cross-contamination risks.

    Product
    LIFEPAK 35 ECG cable REF 11111-000041
    Category
    Medical Device
    Distribution
    Distributed nationwide