The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

5851–5875 of 36553

  • SevereFDA (Devices)·Z-1818-2023·2023-06-28

    Medtronic ICD COBALT XT Recalled for Potential Energy Output Failure

    Medtronic has recalled certain implantable defibrillators (ICDs) due to a potential for reduced or no-energy output during therapy. Affected devices may fail to deliver required treatment for dangerous heart rhythms.

    Product
    ICD COBALT XT VR MRI IS1 DF1, Model Number DVPA2D1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1778-2023·2023-06-28

    Implantable Defibrillators May Deliver Reduced Energy During Therapy

    Medtronic ICDs and CRT-Ds with a specific feedthrough may deliver reduced or no energy during high voltage therapy. Approximately 2,669 units are affected in the US and worldwide.

    Product
    CRTD COBALT XT HF QUAD MRI IS4 DF1, Model Number DTPA2Q1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1717-2023·2023-06-28

    Implantable Cardioverter Defibrillators Risk Reduced or No Therapy Output

    Certain Medtronic implantable cardioverter defibrillators and cardiac resynchronization defibrillators may fail to deliver energy during high-voltage therapy due to a specific feedthrough design issue. The recall affects 3,801 units distributed in the US and worldwide.

    Product
    ICD-DR DDMD3D1 PRIMO MRI, Model Number DDMD3D1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1726-2023·2023-06-28

    Medtronic ICD COBALT DR Potential Reduced Energy Output During Therapy

    Medtronic's ICD COBALT DR MRI defibrillators may fail to deliver high-voltage therapy due to a manufacturing defect in the device feedthrough. The rare potential affects 11,645 units distributed worldwide.

    Product
    ICD COBALT DR MRI IS1 DF4, Model Number DDPB3D4; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1793-2023·2023-06-28

    Implantable Defibrillators May Produce Reduced or No Energy Output

    Medtronic implantable cardioverter defibrillators may produce reduced or no-energy output during high voltage therapy due to a defective feedthrough component. The defect affects 176 units distributed worldwide.

    Product
    ICD-VR VISIA AF S US/OUS IS1/DF1, Model Number DVAC3D1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1800-2023·2023-06-28

    Medtronic implantable defibrillators recalled for potential therapy delivery failure

    Medtronic's ICD and CRT-D devices may fail to deliver high-voltage therapy due to a defect in a specific feedthrough component. Patients should contact their healthcare provider immediately to discuss the risk.

    Product
    ICD-VR DVBC3D4 EVERA S DF4 GLOB, Model Number DVBC3D4; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1747-2023·2023-06-28

    Implantable Cardioverter Defibrillators Recalled for Potential High-Voltage Therapy Failure

    Medtronic is recalling 7 implantable cardioverter-defibrillators that may fail to deliver electrical therapy during critical heart rhythms. The defect affects devices with a specific feedthrough component.

    Product
    CRT-D DTBB2Q1 VIVA QUAD S IS4/DF1 INTL, Model Number DTBB2Q1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1757-2023·2023-06-28

    Implantable Cardioverter Defibrillators May Fail to Deliver Therapy

    3,570 implantable cardioverter defibrillators and cardiac resynchronization defibrillators with a specific feedthrough defect may fail to deliver high-voltage therapy when needed.

    Product
    CRTD DTMA2D1 CLARIA MRI OUS DF1, Model Number DTMA2D1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1722-2023·2023-06-28

    Implantable cardioverter defibrillators recalled for potential therapy delivery failure

    Medtronic implantable cardioverter defibrillators (ICDs) with a specific glassed feedthrough are recalled due to a rare potential for reduced or no energy output during high voltage therapy.

    Product
    ICD DDPA2D1G COBALT XT DR MRI DF1 GOLD, Model Number DDPA2D1G; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1781-2023·2023-06-28

    Implantable Cardiac Devices Risk Therapy Failure From Feedthrough Defect

    Certain Medtronic implantable cardioverter defibrillators may fail to deliver high-voltage therapy due to a defective feedthrough component. The FDA classified this as a Class I recall affecting 2,884 devices.

    Product
    CRTD COBALT HF MRI IS1 DF1, Model Number DTPB2D1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0893-2023·2023-06-28

    Prescription Drug Recall: Ziprasidone Cartons Contain Wrong Medication

    Unit Dose cartons labeled as Ziprasidone Hydrochloride 20 mg were found to contain Dronabinol 2.5 mg instead. Lot T04769 (Exp. 2024/12) was distributed nationwide.

    Product
    ZIPRASIDONE — ZIPRASIDONE (ZIPRASIDONE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1759-2023·2023-06-28

    Implantable Cardiac Defibrillators May Fail During High-Voltage Therapy

    Certain Medtronic implantable defibrillators may produce reduced or no energy output during high-voltage therapy due to a defective feedthrough component. Affected devices were distributed nationwide and worldwide.

    Product
    CRTD DTMA2Q1 CLARIA MRI QUAD OUS DF1, Model Number DTMA2Q1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1821-2023·2023-06-28

    Implantable cardiac defibrillators recalled for potential therapy failure risk

    Medtronic recalls ICD COBALT VR MRI DF4 defibrillators due to a rare potential for reduced or no energy output during high-voltage therapy. The defect affects devices manufactured with a specific glassed feedthrough component.

    Product
    ICD COBALT VR MRI DF4, Model Number DVPB3D4; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1756-2023·2023-06-28

    Medtronic Implantable Cardioverter Defibrillators May Fail to Deliver Therapy

    Medtronic issued a Class I recall for certain implantable cardioverter defibrillators due to a rare risk that high-voltage therapy may not deliver. Affected models include DTMA1QQ devices made with a specific feedthrough component.

    Product
    CRTD DTMA1QQ CLARIA MRI QUAD US DF4, Model Number DTMA1QQ; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1815-2023·2023-06-28

    Implantable Defibrillators With Defective Feedthrough May Fail During Critical Therapy

    Medtronic is recalling 14,270 implantable cardioverter defibrillators with a specific feedthrough that may produce reduced or no energy output during high-voltage therapy. The affected devices may fail to deliver critical treatment when needed.

    Product
    ICD-VR DVMD3D4 PRIMO MRI, Model Number DVMD3D4; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1779-2023·2023-06-28

    Implantable Defibrillators May Fail to Deliver Critical Heart Therapy

    Certain Medtronic implantable cardioverter defibrillators may produce reduced or no energy output during therapy delivery due to a defective feedthrough component. No injuries have been reported, but patients may not receive proper treatment for life-threatening heart rhythms.

    Product
    CRTD COBALT XT HF QUAD MRI IS4 DF4, Model Number DTPA2QQ; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1789-2023·2023-06-28

    Implantable Cardioverter Defibrillators May Fail to Deliver Therapy

    Medtronic implantable defibrillators with certain feedthroughs may fail to deliver high-voltage therapy when needed. This rare malfunction could prevent life-saving electrical treatment.

    Product
    ICD-VR DVAB1D1 VISIA AF US IS1/DF1, Model Number DVAB1D1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1795-2023·2023-06-28

    Implantable Defibrillators May Deliver Reduced or No Energy During Therapy

    Certain Medtronic implantable cardioverter defibrillators with a specific feedthrough may produce reduced or no energy output during high voltage therapy. The rare defect affects 16 units distributed nationwide.

    Product
    ICD-VR DVBB1D1 EVERA XT IS1/DF1 US, Model Number DVBB1D1; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1773-2023·2023-06-28

    Implantable Defibrillators May Fail to Deliver Critical Therapy

    Medtronic implantable defibrillators may produce reduced or no energy output during high-voltage therapy delivery. Affected devices were manufactured with a specific feedthrough component.

    Product
    CRTD DTMC2QQ COMPIA MRI QUAD OUS DF4, Model Number DTMC2QQ; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0990-2023·2023-06-28

    Miyako Select Shredded Crab Meat recalled for undeclared wheat and eggs

    Aquamar Inc is recalling Miyako Select shredded crab meat and related crab-flavored seafood products due to undeclared wheat and eggs allergens. The recall affects approximately 31,079 cases distributed across the United States and Canada.

    Product
    Miyako Select Shredded Crab Meat Keep Refrigerated #1485 Ingredients: Fish Protein (Pollock, Threadfin Bream and/or Flying Fish), Water, Potato Starch, Modified Food Starch, Contains less than 2% of the following: Sugar, Salt, Sorbitol, Carrageenan, Natural and Artificial Flavors
    Category
    Food
    Distribution
    12 states
  • SevereFDA (Devices)·Z-1776-2023·2023-06-28

    Medtronic Implantable Defibrillators May Fail Therapy Energy Delivery

    Medtronic recalls 3 COBALT XT implantable defibrillators that may deliver reduced or no energy during therapy. A defect in the device feedthrough could prevent effective treatment of abnormal heart rhythms.

    Product
    CRTD DTPA2D1PX COBALT XT HF QUAD OUS, Model Number DTPA2D1PX; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1809-2023·2023-06-28

    Medtronic Implantable Defibrillators May Fail to Deliver High-Voltage Therapy

    Medtronic implantable defibrillators with a specific feedthrough defect may rarely experience reduced or no-energy output during high-voltage therapy. Patients should contact their healthcare provider for evaluation.

    Product
    ICD-VR DVMB1D4 EVERA MRI XT DF4 US, Model Number DVMB1D4; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1826-2023·2023-06-28

    ARROW Endurance Peripheral Catheters Recalled for Separation and Leakage Risk

    ARROW Endurance Extended Dwell Peripheral Catheters are being recalled due to potential catheter separation or leakage. The recall affects 262,016 units distributed nationwide and in Canada.

    Product
    ARROW Endurance Extended Dwell Peripheral Catheter System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1723-2023·2023-06-28

    ICD COBALT XT Defibrillators Recalled for Potential Reduced Energy Output

    Medtronic recalled 22,114 ICD COBALT XT defibrillators due to a rare potential for reduced or no energy output during high-voltage therapy delivery caused by a specific feedthrough defect.

    Product
    ICD COBALT XT DR MRI IS1 DF4, Model Number DDPA2D4; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1752-2023·2023-06-28

    Medtronic CRT-D BRAVA Implantable Defibrillators—Potential High-Voltage Therapy Failure

    Medtronic implantable cardioverter defibrillators with specific feedthrough components may fail to deliver high-voltage therapy during treatment. Affected units are being recalled due to risk of reduced or absent energy output.

    Product
    CRT-D DTBC2QQ BRAVA QUAD IS4/DF4 INTL, Model Number DTBC2QQ; Implantable Cardioverter Defibrillators
    Category
    Medical Device
    Distribution
    Distributed nationwide